The Study of the Method for Validating the Performance of Quantitative Tests for the Electrochemiluminescence Immunoassay System of Elecsys 2010
Author: YangJingRui
Tutor: ZhangRunLing
School: Lanzhou University
Course: Clinical Laboratory Science
Keywords: Evidence-based laboratory medicine Chemiluminescent immunoassay Reference range Human chorionic gonadotropin Quantitative detection performance verification
CLC: R446.6
Type: Master's thesis
Year: 2007
Downloads: 146
Quote: 0
Read: Download Dissertation
Abstract
|
Objective: Evidence-based laboratory medicine (evidence-based laboratory medicine, EBLM) under the guidance of the Elecsys 2010 electrochemical luminescence immunoassay ( electrochemiluminescence immunoassay, ECLIA) analytical performance validation , explore performance ECLIA detection system analysis applies to authentication mode . Explore three different instruments detected the comparability of results of the same test items . Methods: ECLIA different concentrations of serum specimens for testing the performance of instrumental analysis precision , analytical sensitivity , linear range , accuracy and verification tests of the reference range ; application of three different instruments were used to detect the 60 serum samples , application SPSS10 .0 software for statistical analysis of the results . Results: imprecision of the coefficient of variation ( coefficient of variation , CV) of 1.07 % to 3.73% , and between CV_s 0.43 % to 2.12% of the total imprecision CV_s 1.81% to 4.90 % ; recovery test recovery of 94% -110 % ; analytical sensitivity < 0.1mIU/ml ; the linear range 0.1mIU/ml to 9897.225mIU/ml ; theoretical value with repeated measured values ??good linear ( r = 0.999 , P = 0.000 ) ; accuracy verification comparability of the comparative method detection results are not very satisfactory ( r = 0.63 , P = 0.000 ) ; 8w, 12w, 16wβ -HCG reference range than the manufacturers to smaller ( P <0.00 , P <0.002 , P < 0.010 ) . The three detection system ECLIA with CLA correlation coefficient of r = 0.72 ( P = 0.000 ) , by ECLIA and RIA correlation coefficient of r = 0.61 ( P = 0.000) , the RIA and CLA correlation coefficient r = 0.60 ( P = 0.000 ) . Conclusion : ECLIA is a high precision , analytical sensitivity , wide linear range, high accuracy and detection speed automated immunoassay technology has good prospects. Especially for its reference range whether hormones applies to people also need to be further explored . Comparability between the three kinds of instrument test results are not very satisfactory .
|
Related Dissertations
- Setup of Systematic Theory of Evidence-based Laboratory Medicine and the Construction of Teaching Model in Clinic,R4-4
- Effect of HCG on PPARγ and Adiponectin mRNA Expression in 3T3-L1 Adipocytes,R714.256
- Establishment and Evaluation of Time-resolved Fluoroimmunoassay and LICLIA for Enrofloxacin,S859.79
- Description and Application of Several Methods for Detection of Human Cardiac Troponin I,R446.6
- Clinical and Experimental Study on Predection of Hydatidiform Mole Malignant Tendency and Attenuation Synercy of Qingduyin,R271.9
- Research on Measurement and Control System of Automated Chemiluminescent Immunoassay Analyzer,TP216.3
- Expression of Cytokines and Growth Factors during Human Embryo Implantation and Regulation of IL-1β and HCG,R321
- 1.The Reference Range and Associated Factors of Blood Pressure Variability in Elders 2.Effect of Amlodipine and Felodipine on Blood Pressure and Blood Pressure Variability in Old Essential Hypertension,R544.1
- Maternal serum inhibin A concentration and abnormal pregnancy Correlation,R714.2
- The Clinical and Laboratory Research on the Change of Thyroid Function in Hyperemesis Gravidarum Women,R714.2
- Study on Anatomic Measurement of Oropharynx Dimensions,R766
- The Study and Clinical Application on High-throughput, Low-cost Testing System,R446.1
- The Utility of β-hCG Expressing SiHa Cervical Cell Line on Quantifying Tumor Mass in Living Animal,R737.33
- To Study the Value of PSV、EDV、RI and β-HCG、PROG in the Drug Treatment of the Early-Stage Ectopic Pregnancy,R714.22
- Expression and Regulation of Cyclin G1 in Mouse Granulosa Cells,Q343
- Induction Polycystic Ovarian Syndrome by Insulin and Human Chorionic Gonadotropin in Rats and Research of Apoptotic Modulation,R711.75
- The Value of F-β-HCG, PROG, CK, β-HCG in the Diagnosis of Ectopic Pregnancy,R714.22
- Construction and Expression of the Recombinant Plasmid pPIC9K-pZP3α-hCGβ-CTP~(109~145) in the Yeast Pichia Pastoris,R392.11
- The Observation of Endometrial Histology During Different Ovarian Stimulation Protocols in Rats,R965
- Relationship between Maternal Serum Matrix Metalloproteinase-9 and β-hCG Concentrations and Preterm Delivery and Term Labor,R714
CLC: > Medicine, health > Clinical > Diagnostics > Laboratory diagnosis > Immunology Examination
© 2012 www.DissertationTopic.Net Mobile
|