The Study of the Method for Validating the Performance of Quantitative Tests for the Electrochemiluminescence Immunoassay System of Elecsys 2010

Author: YangJingRui
Tutor: ZhangRunLing
School: Lanzhou University
Course: Clinical Laboratory Science
Keywords: Evidence-based laboratory medicine Chemiluminescent immunoassay Reference range Human chorionic gonadotropin Quantitative detection performance verification
CLC: R446.6
Type: Master's thesis
Year: 2007
Downloads: 146
Quote: 0
Read: Download Dissertation

Abstract


Objective: Evidence-based laboratory medicine (evidence-based laboratory medicine, EBLM) under the guidance of the Elecsys 2010 electrochemical luminescence immunoassay ( electrochemiluminescence immunoassay, ECLIA) analytical performance validation , explore performance ECLIA detection system analysis applies to authentication mode . Explore three different instruments detected the comparability of results of the same test items . Methods: ECLIA different concentrations of serum specimens for testing the performance of instrumental analysis precision , analytical sensitivity , linear range , accuracy and verification tests of the reference range ; application of three different instruments were used to detect the 60 serum samples , application SPSS10 .0 software for statistical analysis of the results . Results: imprecision of the coefficient of variation ( coefficient of variation , CV) of 1.07 % to 3.73% , and between CV_s 0.43 % to 2.12% of the total imprecision CV_s 1.81% to 4.90 % ; recovery test recovery of 94% -110 % ; analytical sensitivity < 0.1mIU/ml ; the linear range 0.1mIU/ml to 9897.225mIU/ml ; theoretical value with repeated measured values ??good linear ( r = 0.999 , P = 0.000 ) ; accuracy verification comparability of the comparative method detection results are not very satisfactory ( r = 0.63 , P = 0.000 ) ; 8w, 12w, 16wβ -HCG reference range than the manufacturers to smaller ( P <0.00 , P <0.002 , P < 0.010 ) . The three detection system ECLIA with CLA correlation coefficient of r = 0.72 ( P = 0.000 ) , by ECLIA and RIA correlation coefficient of r = 0.61 ( P = 0.000) , the RIA and CLA correlation coefficient r = 0.60 ( P = 0.000 ) . Conclusion : ECLIA is a high precision , analytical sensitivity , wide linear range, high accuracy and detection speed automated immunoassay technology has good prospects. Especially for its reference range whether hormones applies to people also need to be further explored . Comparability between the three kinds of instrument test results are not very satisfactory .

Related Dissertations

  1. Setup of Systematic Theory of Evidence-based Laboratory Medicine and the Construction of Teaching Model in Clinic,R4-4
  2. Effect of HCG on PPARγ and Adiponectin mRNA Expression in 3T3-L1 Adipocytes,R714.256
  3. Establishment and Evaluation of Time-resolved Fluoroimmunoassay and LICLIA for Enrofloxacin,S859.79
  4. Description and Application of Several Methods for Detection of Human Cardiac Troponin I,R446.6
  5. Clinical and Experimental Study on Predection of Hydatidiform Mole Malignant Tendency and Attenuation Synercy of Qingduyin,R271.9
  6. Research on Measurement and Control System of Automated Chemiluminescent Immunoassay Analyzer,TP216.3
  7. Expression of Cytokines and Growth Factors during Human Embryo Implantation and Regulation of IL-1β and HCG,R321
  8. 1.The Reference Range and Associated Factors of Blood Pressure Variability in Elders 2.Effect of Amlodipine and Felodipine on Blood Pressure and Blood Pressure Variability in Old Essential Hypertension,R544.1
  9. Maternal serum inhibin A concentration and abnormal pregnancy Correlation,R714.2
  10. The Clinical and Laboratory Research on the Change of Thyroid Function in Hyperemesis Gravidarum Women,R714.2
  11. Study on Anatomic Measurement of Oropharynx Dimensions,R766
  12. The Study and Clinical Application on High-throughput, Low-cost Testing System,R446.1
  13. The Utility of β-hCG Expressing SiHa Cervical Cell Line on Quantifying Tumor Mass in Living Animal,R737.33
  14. To Study the Value of PSV、EDV、RI and β-HCG、PROG in the Drug Treatment of the Early-Stage Ectopic Pregnancy,R714.22
  15. Expression and Regulation of Cyclin G1 in Mouse Granulosa Cells,Q343
  16. Induction Polycystic Ovarian Syndrome by Insulin and Human Chorionic Gonadotropin in Rats and Research of Apoptotic Modulation,R711.75
  17. The Value of F-β-HCG, PROG, CK, β-HCG in the Diagnosis of Ectopic Pregnancy,R714.22
  18. Construction and Expression of the Recombinant Plasmid pPIC9K-pZP3α-hCGβ-CTP~(109~145) in the Yeast Pichia Pastoris,R392.11
  19. The Observation of Endometrial Histology During Different Ovarian Stimulation Protocols in Rats,R965
  20. Relationship between Maternal Serum Matrix Metalloproteinase-9 and β-hCG Concentrations and Preterm Delivery and Term Labor,R714

CLC: > Medicine, health > Clinical > Diagnostics > Laboratory diagnosis > Immunology Examination
© 2012 www.DissertationTopic.Net  Mobile