Abstract
|
The enzymatic electrode is one kind of electrochemical biosensorsthat combines highly specific enzymatic catalytic reactions with highlysensitive electrochemical detection, which has developed very rapidly inthe past decades.The electrochemical quartz crystal impedance analysis (EQCIA) isan important analytical method for monitoring the processes ofchemo-/bio-modification on electrode surfaces, via a simultaneous andrapid measurement of the electroacoustic impedance for the piezoelectricquartz crystal (PQC) resonance, from which multiple chemical/physicalparameters and material-relevant characteristics during anelectrochemical perturbation can be acquired, such as electrode-masschanges down to the nanogram level, the solution viscodensity, and theelasticity of modified films.In the present thesis, we have carried out some innovative researcheson the electrodeposition of chitosan (CS), the immobilization of glucoseoxidase (GOD) and constructions of enzymatic electrodes. The maincontents are as follows,1. The concept and construction of the biosensors, mainly involvingimmobilization methods for biomolecules, as well as the principle andapplication of the electrochemical quartz crystal microbalance(EQCM), have been briefly reviewed.2. A novel method to immobilize GOD in 1,4-Benzoquinoneelectroreduction-induced deposition of thickness-controllableenzyme-chitosan-MWCNT nanocomposite film has been proposed. The EQCIA technology was used to monitor the process of chitosandeposition on the Au electrode. The result suggested that the chitosanfilm deposited by electroreduction was nonrigid hydrogel. A glucosebiosensor with good performance was thus fabricated, and comparedwith the sensors via H2O2 or H2O electroredution method. The effectsof experimental parameters on the sensor performance, includingapplied potential, solution pH were examined. At an optimal potentialof 0.7 V vs SCE, the current response of the biosensor in selectedphosphate buffer (pH 7.0) was linear with glucose concentration from0.005 to 8 mM, with lower limit of detection of 2μM (S/N=3), shortresponse time (within 15s), The Michaelis constant (Kmapp) wasestimated as 6.8 mM.3. The EQCIA technology was used to monitor the process ofelectrodeposition of Prussian blue (PB) on Au electrode. A hydrogenperoxide (H2O2) biosensor with good performance was constructed,via the quantity optimization for PB, and effects of experimentalparameters on the sensor performance, including applied potential,solution pH and electroactive interferents, were examined. At anoptimal potential of-0.25 V vs SCE, the current response of thebiosensor in the selected phosphate buffer (pH 7.0) was linear with theconcentration of H2O2 from 1μM to 5 mM, with a lower limit ofdetection of 0.27μM (S/N=3), short response time (within 10s). Thebiosensor exhibited good storage stability.4. A new enzymatic electrode with cost effectiveness and goodperformance for glucose detection was developed by codepositingglucose oxidase into the polymer from electrochemical oxidation of dopamine (DA) on a Pt-modified 8B pencil lead electrode. Effects ofconcentrations of phosphate buffer, DA and GOD were investigated.At the optimal potential of 0.65 V versus the KCl-saturated calomelelectrode (SCE), the current response of the biosensor in the selectedphosphate buffer (pH 7.0) was linear with the concentration of glucosefrom 0.05 to 12 mM, with a lower detection limit of 6μM (S/N=3),short response time (within 15s) and good anti-interferent ability. TheMichaelis constant (Kmapp) was estimated to be 9.21 mM. Thebiosensor exhibited good storage stability, i.e. 97% of its initialresponse was retained after 7-day storage in the selected phosphatebuffer at 4℃, and even after another three weeks the biosensorretained 93% of its initial response.
|
Related Dissertations
- New Technology and Basic Study on the Direet Preparation of PbO Powder from Galena by Selective Leaching Technology,TQ134.33
- The Effects of Exogenous H2O2 and AsA on Hyperhydricity and the Characteristics of Endogenous Reactive Oxygen Species Metabolism of the Garlic Plantlet in Vitro,S633.4
- Kinase Activities Analysis and Localization of ZmCCaMK Induced by Abscisic Acid in Leaves of Maize Plants,S513
- Heme Oxygenase is Involved in Salinity-Induced Tomato Lateral Root Development and Its Relationship with Hydrogen Peroxide,S641.2
- The Research on Hydrogen Peroxide Sensor Based on Nanomaterials Modified Electrodes,TP212.2
- Study on Influential Factor to Methane Metabolic of Methane-utilizing Bacteria and Methoanol Detection Method,Q93
- The Application of Ordered Mesoporous Carbon and Glod Nanoparticles Composite in Bioensor,TB383.1
- Preparation of Low Molecular Weight Chitosan,TQ929.2
- Research on Properties of Lanthanum Oxide-doped Graphene/PTFE Electrode,X703
- Study on the Oxidation System of Ozone or Ozone/Hydrogen Peroxide Promoted by Lewis Acids Containing Titanium,X703
- Effects of Different Temperatures on Redox Status in Pupae of Orthaga Achatina Butler,S763.7
- High Speed ??Rail biological recovery of copper and copper leaching liquid iron Process,X703.1
- Catalytic Degradation of AO7 in the CeO2/H2O2 System,TB383.1
- Effect of Hydrogen Peroxide and X-ray on Calcium Oscillation in Airway Epithelial Cells and Pulmonary Macrophages,R563.9
- Carbide slurry sulfide and cyanide treatment process,X701.3
- Cotton fabrics cryogenic hydrogen peroxide bleaching system research,TS192
- Three parameters of human stress detection system,R318.0
- Rapid Detection of Zoonotic Pathogens Using Leaky Surface Acoustic Biosensor and Rolling Circle Amplification,R440
- The Comparative Study of Two Deproteinized Methods on Xenogeneic Bone Graft Substitute Material,R687.3
- SECM-SPR quantitative release of hydrogen peroxide and its interaction with the metal protein in situ,R363
- Based graphene material , a Novel DNA biosensor,TP212.2
CLC: > Mathematical sciences and chemical > Chemistry > Analytical Chemistry > Instrument analysis ( physics and physical chemistry ) > Electrochemical analysis
© 2012 www.DissertationTopic.Net Mobile
|