Preparation of Three Stationary Phases in High Temperature Gas Chromatography and Their Chromatographic Performance Evaluation

Author: NiuZuoZuo
Tutor: WuBo
School: Shandong University
Course: Analytical Chemistry
Keywords: High temperature gas chromatography Capillary column High Temperature Stationary Phase Carbon film - chemical plating Solvent - gel method
CLC: O657.7
Type: Master's thesis
Year: 2011
Downloads: 25
Quote: 1
Read: Download Dissertation

Abstract


With the development of science and technology as well as the level of analysis have become increasingly demanding, increasingly stringent requirements for high temperature gas chromatography. As we all know, the impact of the use of the temperature of the high temperature gas chromatography has two main aspects: 1. Fixative temperature resistance; capillary column material. In order to get a higher capillary column using temperature must start from these two aspects. Of these two aspects of the modified in several ways: First, the use of better temperature performance of stationary phase, most people use the stationary phase of commercialization polysiloxane people by poly silicone-modified to obtain the temperature better heat resistance of the stationary phase; Second, the change of the column material of the capillary, and currently the most used is the polyimide coated fused silica capillary column, polyimide, whether it is its flexibility or the degree of fit with the capillary column is unparalleled, but it also has a fatal weakness is to use temperature is limited the ordinary polyimide, temperature resistance can only reach 360 to 380 ℃, good poly imides, its heat resistance can only reach 400 to 420 ° C, and at high temperatures, the polyimide layer easily blackened, flexibility deteriorates. There are some people using a stainless steel capillary column instead of a fused silica capillary column, but due to the stainless steel capillary column has more lively and the inner surface, it is not suitable for the analysis of the active substance can react with. Others with metallized capillary column, but due to the coefficient of expansion of the metal and quartz large differences, it is not long-term use, but metallised aluminum capillary its higher production costs, which is also an unfavorable factors limit it uses. To solve the above problem, the subject is first initiated from the stationary phase, we use the polysilazane instead polysiloxane stationary phase, the polysilazane in the massive ring dicarboxylic silazane alkyl groups can be suppressed polymer into the main chain Central degradation. Thereby increasing the temperature of its use, under the premise of using polyimide outer coating of silica capillary in the 400 ° C high temperature, the stationary phase of the baseline drift were less than 1.0mV. We prepared another capillary column, not only from the stationary phase to be modified, but also improve the temperature resistance of the capillary column. Is mainly used for processing in the ordinary polyimide capillary to produce a carbon layer by chemical plating, and then on the outer coated with a layer of Ni-P layer, the carbon layer can play a protective role, quartz and the expansion coefficient of the metallic Ni has also been a certain buffer. This not only solved the problem of the poor heat resistance of the polyimide also be solved, the problem resulting from the use of time is shorter due to the different expansion coefficients of the metal and quartz. The use of the stationary phase, we use the modified polysiloxane, to increase its rigidity, thereby increasing the temperature of its use, by the introduction of benzene ring in the main chain of polysiloxane. The capillary column is greatly increased their use of time, and when the temperature reached 410 ℃ the stationary phase, the baseline drift of less than 1.2mV. Finally, we take advantage of the sol - gel method, good high temperature performance ring disilazane bonded to the capillary wall, this bonding method is more stable than ordinary crosslinked column, high temperature, and the preparation of time is greatly reduced, the preparation method is simple, and is conducive to mass production. The improved method of the above three kinds of a capillary column for gas chromatography only makes some improvement in heat resistance, but also be able to increase their service life, they have their excellent characteristics in a high temperature chromatography, suitable for application in the high-temperature gas chromatography analysis .

Related Dissertations

  1. Preparation of Polymethyl Siloxane Fused-silica Capillary Chromatographic Column and Utilization,O634.41
  2. Synthesis of New Pelysiloxanes as GC Stationary Phase and Its Chromatographic Performance Evaluation,O657.7
  3. Study of Preparation of Multi-layer Open Tubular Capillary Column Coated with Zirconium Phosphonate(ZrP-MOTCC) for Enriching Phosphopeptides,R341
  4. Preparation and Application of a Hydrophilic Monolithic Column for Capillary Liquid Chromatography,O657.7
  5. Preparation and Performance Evaluation of whole / mixed capillary column micro - separation system,R917
  6. Preparation of Diacylglycerol from Esterification of Fatty Acid Catalyzed by Phospholipase A1,TQ463.2
  7. Preparation of New Metal Capillary Column and Its Application in High Temperature Gas Chromatography,O657.71
  8. Synthesis of New Polycyclic Phenyl Group Graft Polysiloxane as GC Stationary Phase and Its Chromatographic Performance Evaluation,O657.7
  9. Preparation and Electrochromatographic Evaluation of Some Novel Embedded Polar Groups Monolithic Silica Capillary Columns,O657.7
  10. Research and Analysis the Residual Solvents in Pharmaceutical Samples,R927
  11. Studies and Applications of New Calixarene Phosphate Derivatives on Gas Chromatographic Behavior,O657.71
  12. New GC capillary column preparation and application of research,X830
  13. The new capillary GC column preparation of its rivals samples and environmental samples split,X830
  14. Sol - gel prepared new capillary GC column,O657.71
  15. Dalian Economic and Technological Development Zone, the detection of volatile organic compounds in air and health risk assessment,X820
  16. Sol - gel technology in the preparation of GC capillary columns .,O657.8
  17. Studies on the Determination of Pesticide Multi-Residues in Foods by Gas Chromatography,TS207
  18. Research and application of new stationary phases in capillary gas chromatography,X131
  19. Capillary gas chromatography chiral stationary phases in its environmental analysis of the application,O657.7
  20. Studies and Applications of New Calixarene Derivatives on Gas Chromatographic Behavior,X132

CLC: > Mathematical sciences and chemical > Chemistry > Analytical Chemistry > Instrument analysis ( physics and physical chemistry ) > Chromatographic analysis
© 2012 www.DissertationTopic.Net  Mobile