Dissertation > Excellent graduate degree dissertation topics show
High energy resolution (e, 2e) spectrometer data acquisition system is developed and its application
Author: LiuTao
Tutor: ChenXiangJun
School: University of Science and Technology of China
Course: Atomic and Molecular Physics
Keywords: Data acquisition system China University of Science and Technology Detection efficiency Energy resolution Correction method Efficiency correction Detector Spectrometer High-resolution Doctoral Dissertation
CLC: O561.4
Type: PhD thesis
Year: 2007
Downloads: 37
Quote: 0
Read: Download Dissertation
Abstract
|
Detailed exposition of this thesis, the multi-parameter line data acquisition system as well as offline data processing software developed for high-energy resolution (e, 2e) spectrometer. Characteristics measured at the same time for the the spectrometer energy, momentum, successfully developed a set of 8-channel signal acquisition and measurement data acquisition systems, and online software has a good user interface is developed using LabVIEW. New data correction method for the detection efficiency may appear uneven, modify and improve off-line data processing software. The high resolution (e, 2e) spectrometer, Ar atom and the CF2Cl2 molecular measuring, testing the data acquisition system and off-line data processing software as well as the efficiency correction method. The thesis includes the following chapters: Chapter introduces the basic principles of electron momentum spectroscopy, experimental arrangements, as well as studies progress and details we recently developed high-energy resolution (e, 2e) spectrometer on the physical requirements of the data acquisition system. In the second chapter, the main spectrometer online data acquisition system. First, the output signal from the position sensitive detector spectrometer analysis of the spectrometer data acquisition system needs, system design principle. Then describes the acquisition system hardware, software components, and debugging. 8-way signal data acquisition system can handle and meet the measurement maximum acquisition rate of 30K Sample / sec. Finally, the Ar atom experiments the data acquisition system were detected. The test results show that the data acquisition system is working properly, and to meet the experimental needs. In the third chapter, the main spectrometer offline data processing process, including relations calibrated ionization spectroscopy of energy and angle position and momentum spectra obtained. A single Lu efficiency correction experimental data of the unevenness of the detection efficiency, and to accidental coincidence background correction and single triangular background correction of the bottom two modified methods were compared, and drawn two methods applicable range. In the fourth chapter, the use of high-energy distinguish (e, 2e) spectrometer measuring the the CF2Cl2 molecular ionization spectroscopy and momentum distribution of the data acquisition system and data processing software to test, and uncorrected and two correction methods The results obtained were compared. The results show that the data acquisition system work well, the data processing program is reliable, efficiency correction method is feasible. In the fifth chapter, a simple cold engraved experiment not only tested the two-dimensional position sensitive detector position linear quality of the output image, and a correction method for output image \The corrected results were assessed. Be significantly improved by correcting image distortion caused by the \The corrected x direction Nonlinear 0.59% from 2.1% before the correction becomes.
|
Related Dissertations
- On Embedding of Some Fault-tolerant Networks,O157.5
- Stochastic Optimal Active/Semi-active Control of Stay Cables,O324
- Pharmacokinetic Drug Interaction Studies of Irinotecan and Its Active Metabolite SN-38 with P-gp Inhibitors,R96
- Synthesis of Aluminophosphate Molecular Sieves with Special Aggregative States and Investigation of Their Growth Mechanism,O643.36
- Studies on Human Amniotic Cells Transplantation Combined with Melatonin Administration to Treat Mouse Parkinson Disease Induced by MPTP,R96
- Screening and identification of the active strains of of feces enterococci PDF inhibitors ; I04 - 4776 , I04 - 5195 strains of biological activity of a number of taxonomic study,R96
- The Analysis of Troposphere Microwave Radar Data, Middle and upper Atmosphere Lidar Data and Their Retrieval Algorithms,P412.2
- Ultrafast Spin Dynamics in Magnetic Thin Films,O484.43
- Establishment of P53 High Throughput Screening Model & Studies of Effects of 42-5 on Renal Insufficiency and Its Mechanisms of Action,R96
- Changes in Sodium Pump Expression Dictate the Effects of Ouabain on Cell Growth,R73-3
- Berberine: For Glucose-Lowering Activity and Molecular Mechanism,S567.239
- Studies on the Total Synthesis of Malyngamides,O621.3
- Effect of Anisotropy of Soft Layer on the Properties of ECC Magnetic Recording Media,TM276
- Studies of Thin Film Materials for Ultra-high Density Magnetic Recording Head,O484.43
- The Study of Two Novel Series of Drugs on Targeting Gene Therapy Against HIV/SIV,R978.7
- Mutation Screening of FBN1 in Patients with Ectopia Lentis and Marfanoid Habitus and Related Gene Chip Designing and Verification,R776
- Research on Legal Issues of Financial Derivatives,D912.28
- , Α-phenyl replace the cinnamamide the synthesis of its vasodilator activity of PAF receptor antagonist - the synthesis and structure-activity relationship studies of aromatic amino ketones Third, natural products, wild chrysanthemum alcohol synthesis,R914
- Study on the Interaction of Some Active Components in Chinese Traditional Medicines with Human Serum Albumin,R285
- Studies on the Green Preparation and Applications of Ag and Ag/ZnO Nanomaterials,TB383.1
CLC: > Mathematical sciences and chemical > Physics > Molecular physics, atomic physics > Molecular Physics > The role of intermolecular excitation and dissociation
© 2012 www.DissertationTopic.Net Mobile
|