Dissertation > Excellent graduate degree dissertation topics show

Study on Detection Technology for Determination of Aflatoxin B1 with High Sensitivity

Author: MaLiang
Tutor: LiPeiWu
School: Chinese Academy of Agricultural Sciences
Course: Quality of agricultural products and food safety
Keywords: Aflatoxin B1 fluorescence enhancement high sensitivity detection technology
CLC: TS207.4
Type: PhD thesis
Year: 2007
Downloads: 733
Quote: 13
Read: Download Dissertation

Abstract


Aflatoxin B1 (AFB1) seriously threatened human and animal healthy or life safety. AFB1 commonly contaminates agricultural commodities, food and animal feedstuffs, which is an important problem all through. Standard of AFB1 limits and technical barriers to trade (TBT) were set by many countries. TBT led to impeded export of agricultural production and damaged the interests of farmers. Development of high sensitivity test method for AFB1 determination is important and crucial to break out TBT. Detection technology with high sensitivity must be studied in order to guarantee agro-food quality control and management from farm to table, find out the contaminated production in time and prevent the production contained excess the standard AFB1 into food chain.Based on the fluorescence characteristic of AFB1, study on how to improve the sensitivity of detection technology was done. First, laser was introduced into the detection technology to induce fluorescence and laser induced fluorescence (LIF)-high performance capillary electrophoresis (HPCE) was developed with high sensitivity. Besides of laser lamp-house researchment, the new fluorescence enhancer of AFB1 was researched and its scientific hypothesis of AFB1 chelation fluorescence enhancement was established and deduced from experiments. The novel post-column derivatization method by high performance liquid chromatography (HPLC) was developed with high sensitivity by applied the new fluorescence enhancer. As fluorescence enhancer, HgCl2 may be induced into IAC fast test method and improved sensitivity. The main conclusions were as follow.1. Laser diode double-pumped solid laser of 375nm wavelength was studied for a new excitation light source and coupled HPCE to detect AFB1 in MECC separation mode. The optimized conditions were as follow. Buffer was composed of 50mmol/L NaDC, 6mmol/L Na2B4O7, 10mmol/L Na2HPO4, 10% Acetonitrile. Excitation wavelength was at 375nm and detected emission wavelength was at 440nm. The applied voltage was 15kV and the current was 104μA. The capillary (75μm i.d., 57 cm total length, 50 cm length to detector) was chosen. The concentration of AFB1 in samples was determined by LIF-HPCE. The results showed that repeatability expressed as RSD values was under 5% and intermediate precision expressed as RSD values was under 3%. Recovery was in the range of 84.1-96.1%. The data also fit the line y= 106x + 319847 (R2=0.9988) in the linear range of AFB1. For sample injection volume being little, the absolute limit of detection (0.17pg) and quantitative limit of AFB1 (0.56pg) were far lower than other method. The absolute mass detection sensitivity of LIF-HPCE improved three magnitudes relatived to AFB1 detection method2. Fluorescence spectrums and fluorescence signal changes of fluorescence system were researched and fluorescence enhancement technology chelated by metal ions was introduced into AFB1 fluorescence detection. The result showed that HgCl2 solvent could be a new enhancer to AFB1 being enhanced the fluorescence intensity of AFB1 rapidly, steadily, intensively in the room temperature. The enhanced condition influenced fluorescence system of AFB1-Hg (II) was studied. The room temperature was accepted. The fluorescence enhancement reaction could balance and complete basically within the 2min when the molar ratio of Hg (II) and AFB1 should exceed 1:1. In the same condition, enhanced fluorescence intensity by HgCl2 was stronger than that of Br2. The sensitivity of AFB1 detection was improved by HgCl2 enhancement. Fluorescence enhancement hypothesis of AFB1 chelation with HgCl2 was established and deduced. In the process of AFB1 fluorescence enhancement, octahedral chelated resultant came into being and light redox reaction in LMCT occured and formed steady chelated products. Steady chelated products could extend rigidity plane or conjugate structure and fluorescence intensity was enhanced greatly by fluorescence efficiency being improved3. A novel post-column derivatization method for simultaneous enhancement of aflatoxin B1, B2, G1, G2, and M1 by HPLC was developed. The aqueous solution of Mercuric Chloride was utilized as a new fluorescence enhancer for aflatoxin B1, G1, and M1 in post-column. Full separation of five aflatoxins with fluorescence detector (λax=365nm,λam=440nm) could be achieved in the baseline by the mobile phase composed of methanol-acetonitrile-water (22:18:60 v:v:v) within 13 minutes. The flow rate of flow phase was 0.8mL/min and the flow rate of enhancer was 0.4mL/min. Sample injection was 10μL. The sensitivity was improved by the fluorescence intensity enhancement of HgCl2. The limit of detection of AFB1 was 0.05μg/kg and limit of quantitative of AFB1 was 0.17μg/kg. The absolute mass detection sensitivity improved above two magnitudes relatived to AFB1 detection method. Repeatability expressed as RSD values was 1.81% and intermediate precision expressed as RSD values was 4.28%. Recovery was in the range of 84.67-91.10%. The new method was proven to be an efficient method with high sensitivity, high accuracy and high repeatability for simultaneous determination of aflatoxins and successfully applied to analyze aflatoxins in contaminated peanut, rice, corn, peanut oil, and peanut butter.4. Fluorescence enhancement of HgCl2 may be induced into IAC fast test method and sample pretreatment technology was developed for AFB1 determination accurately, fast, conveniently in agricultural production and food. The limit of quantitative was 0.3μg/kg. The recovery of AFB1 in spiked samples was above 90%. Repeatability expressed as RSD values was under 3% and R2 was 0.99. The test time was shorter than 40min of single sample. The pretreatment process was simple and timesaving for whole process time of single sample being within 40min and the time was shorter when sample amount increased. The fast test method fit for test in spot and port etc with highlighted advantages such as high accuracy, low-cost, simple-manipulation, fast-run, high safety and so on.

Related Dissertations

  1. The Study on the Detection Technologies and Equipment of Flue-cured Tobacco Leaves Physical Performance Parameters,S572
  2. The Apoptosis Mechanism Induced by Aflatoxin B1 and Deoxynivalenol in Primary Hepatocyte of Cyprinus Carpio,S856.9
  3. Immunosuppressive Effects of Aflatoxin B1 in Canine,S858.292
  4. Spectral and Electrochemical Research of Epirubicin Hydrochloride with Its Analytical Application,TQ465
  5. Study and Application of the Safety Mining Technology in Fullly Mechanized Face under the Danger of Small Skiln Soaf,TD752.2
  6. Change and Value of Serum Soluble Lectin-Like Oxidized Low-Density Lipoprotein Receptor-1 in Acute Coronary Syndrome,R541.4
  7. Effects of Telmisartan on hs-CRP and HMW-adiponectinin Patients with Essential Hypertension,R544.1
  8. Study on Clinical Value of High-sensitivity Cardiac Troponin T Assay in Myocardial Infarction,R542.22
  9. Correlation Analysis between Coronary Lesion Severity and Peripheral Blood Cell CD34~+ Ratio in the Coronary Heart Disease Patients Complicating Diabetes Mellitus,R541.4
  10. Application and Significance of CISS Classification and TOAST Subtype on Ischemic Stroke (Attach 210 Cases Analysis),R743.3
  11. Ankle-brachial index combined ultra- sensitivity C-reactive protein determination of the value of coronary artery disease,R541.4
  12. Individuals with type 2 diabetes, serum complement factor H, hs-CRP levels and insulin resistance study,R587.1
  13. Synthesis and Optical Property of White Luminescence of Dy3+ Ions Doped 12CaO·7Al2O3 Nanopowders Under UV Light Excitation,O482.3
  14. Synthesis and Responsive Behavior of Amphiphilic Azobenzene Functionalized Block Copolymers,O631.3
  15. Fluorescent Enhancement of Guest Molecules by Supramolecular Hydrogel,O648.17
  16. S100A12 in Coronary Atherosclerotic Heart Disease Expression and Significance,R541.4
  17. Inflammatory and coagulation factors and CRP1059G / C gene polymorphism and pulmonary thromboembolism associated,R563.5
  18. The Dynamic Variation of Serum Visfatin Level in Acute Coronary Syndrome Patients and Its Clinical Significance,R541.4
  19. Effect of Atorvastatin on the Concentration of Plasma Asymmetric Dimethylarginine in Acute Myocardial Infarction Patients during PCI Perioperative Period,R541.4
  20. High sensitivity wireless control timing receiver with AGC,TN851
  21. The Rapid Detection of Technology of the Nitrite and Sulfite in Pickled Potherb Mustard,TS255.7

CLC: > Industrial Technology > Light industry,handicrafts > Food Industry > General issues > Food standards and testing > Microbiological testing of food
© 2012 www.DissertationTopic.Net  Mobile