Dissertation > Excellent graduate degree dissertation topics show
Electrochemical Biosensing Based on Biological Macromolecule Modified Electrodes
Author: SunYuXue
Tutor: YeYongKang
School: Hefei University of Technology
Course: Of Food Science
Keywords: Macroporous ordered silica foam glucose oxidase Direct electrochemistry Aflatoxin B1 Antibody-aflatoxin B1 ssDNA Biosensor
CLC: TP212
Type: Master's thesis
Year: 2013
Downloads: 39
Quote: 0
Read: Download Dissertation
Abstract
|
Electrobiosensing technology is considered to be a promising analyticalmethod, which is due to its low cost, high sensitivity and easily miniaturization andautomation. In this paper, Glassy carbon electrode (GCE) were modified as enzymesensors to determine glucose; Au electrode were modified as DNA damage sensorsand immunosensors to determine aflatoxin B1.This thesis includes:1. Direct electrochemistry of glucose oxidase immobilized on macroporousordered silica foam modified glassy carbon electrodeGlucose oxidase@Macroporous ordered silica foam modified GCE wereprepared with optimum concentration of optimal PBS pH7.0, the best modificationconcentration of Glucose oxidase was550U mL-1,and the best modification amountof Macroporous ordered silica foam was7μg. i-t curves was used to make theglucose calibration curve: i (μA)=3.205C+1.067, the correlation coefficient Rwas0.999,the linear detection range was from501850μmol L-1,the apparentMichaelis-Menten constant for glucose was2.073mmol L-1.2. AFB1biosensor based on aAFB1@AuNPs/AuHere, a rapid method for AFB1was designed by Au electrode modified byaAFB1@AuNPs as an electrochemical biosensor. Impedance spectrums、cyclicvoltammetry and Differential Pulse Voltammetry were used to characterize theelectrochemical response of AFB1at Au electrode, and investigate the optimalconditions, such as modified AFB1by4℃、8h, the pH value of PBS is7.4. Underthe optimized conditions, calibration curve: i (μA)=0.02166C+18.8682, thelinear correlation coefficient R=0.9997; the linear range is1.427150ng mL-1.The biosensor was used to determine several pig diets samples successfully whichrecoveries was from94.44%to101.36%.3. AFB1biosensor based on ssDNA modified Au electrodePreparing an AFB1biosensor based on ssDNA modified Au electrode with MBas indicator. ssDNA/Au was prepared as following: using–SHssDNA assembled 12h,and then, soaking in AFB1solutions500s. The concentration of MB was3.0×10-5 mol L-1, and the pH value of Tris-HCL buffer solutions was8.5. Thestandard curve for i (μA)=-0.00059C+0.3299, the linear correlation coefficient R=0.9942, and the limit detection was9.7ng mL-1.
|
Related Dissertations
- Expression of Glucose Oxidase Gene from Aspergillus Niger Z-25 in Pichia Pastoris,Q78
- The Apoptosis Mechanism Induced by Aflatoxin B1 and Deoxynivalenol in Primary Hepatocyte of Cyprinus Carpio,S856.9
- Immunosuppressive Effects of Aflatoxin B1 in Canine,S858.292
- Construction of Protic Ionic Liquid Modified Electrode and Its Enhanced Action in Direct Electron Transfer of GOD,O646
- Study on Influential Factor to Methane Metabolic of Methane-utilizing Bacteria and Methoanol Detection Method,Q93
- The Application of Ordered Mesoporous Carbon and Glod Nanoparticles Composite in Bioensor,TB383.1
- Preparation of Gold and Silver Core-Shell Nanostructure and Their Localized Surface Plasmon Resonance for Sensing,TB383.1
- Studies on the Application of Graphene Modified Electrodes in Electrochemical Biosensors,O657.1
- Research of Dual-channel DNA Electrochemical Biosensor,TP212.3
- Investigation of SPR Waveguide Sensor Based on Angular Interrogation,TN256
- Design of Software System for Automatic Multifunctional Cell Physiological Analyzer,TP212.3
- Design and Fabrication of Porous Silicon Microcavities and Realization of Multichannel System,TP212.3
- Research on the Role Enhancing SPR Sensor’s Sensitivity by Gold Nanorods,TP212.3
- Study on the Fabrication and Electrochemical Biosensor Properties of TiO2 Nanotubes Arrays Modified Electrode,TP212.3
- Direct Electrochemistry of Proteins on CdTe Quantum Dots,O646
- Different electrical properties of carbon nanotubes covalently modified FAD molecular dynamics simulation,TB383.1
- Three parameters of human stress detection system,R318.0
- Rapid Detection of Zoonotic Pathogens Using Leaky Surface Acoustic Biosensor and Rolling Circle Amplification,R440
- The Competitive Inhibition Assay and Experimental Study on Antibiotics and Melamine Residues in Milk,TS252.7
- Study on the Preparation and Properties of Functionalized Carbon Nanotubes,TB383.1
- Preparation of Gold-Maghemite Nanocomposites,TB383.1
CLC: > Industrial Technology > Automation technology,computer technology > Automation technology and equipment > Automation components,parts > Transmitter ( converter),the sensor