Research on Key Issues of Protective Relaying for Ultra High Voltage Synchronous Power Grid
Author: ZuoXiaoQing
Tutor: YangQiXun; XuZhenYu
School: North China Electric Power University
Course: Proceedings of the
Keywords: Ultra High Voltage (UHV) power swing blocking fault phaseselection zero sequence protection secondary arc current fault locating
CLC: TM774
Type: PhD thesis
Year: 2013
Downloads: 124
Quote: 0
Read: Download Dissertation
Abstract
|
The electrical power energy and load center in China are distributed inversely, therefore the UHV (Ultra High Voltage) synchronous power grid is necessary for the huge power transmission over long corridors, as well as the optimal configuration over wide regions. It is well understood that the protective relaying is always recognized as primary defending line for the security and reliability of power system. As a result, the new issues of protection strategy for UHV synchronous power grid should be reconsidered deeply. Five critical issues of protective relaying in UHV synchronous power grid and two UHV transmission lines are investigated in this paper, which are described as below.Firstly, power swing is always a threaten common and influential for power system, which may become one of the most significant reasons for blackout. Nowadays, the power swing blocking strategy of distance relay in China is that the distance relay zone-Ⅰ and zone-Ⅱ are only available in the initial time quantum for about150ms to300ms, defined as the open-time, based on the operation experiences and statistic datum over years. However, the theoretical analysis for this open-time is still a blind area considering the complicated operating conditions of power system. Therefore the open-time is analyzed theoretically. The reasonable model for power system is chosen, which is utilized to establish a complicated relationship between the rotor characteristics in the first swing period and the equivalent power angle. The equivalent power angle is defined as the angle that makes the measured impedance of distance relay zone-Ⅱ swing into its protective region. The analysis involved is expected to be an important supplement for the theory basis of power swing blocking strategy in China. At the same time, the correct fault phases discrimination during power swing is also difficult, which is the second research aspect in this paper. Nowadays, one of the fault phases selector widely used in China is based on the relative phases between fault current of zero-sequence and negative sequence with additional confirmation by impedance measurements. The measured impedance of distance relay during power swing is comprehensively analyzed in this paper. Then a new fault phases selective principle is proposed based on the fault phases selector mentioned above, appropriate for normal operation state and power swing. A delay of200ms is added for the measured impedance of un-faulted phases to swing out of its protective region. The new fault phases selector proposed in this paper was utilized in real project. The matches with other protective schemes are easy and reliable, making it more valuable in an engineering point of view.Thirdly, the first UHV demonstration project from Jindongnan to Jingmen is of great importance for the future UHV power grid in China. The protection schemes for this transmission line are investigated in details, a special problem was observed on the Jindongnan-Nanyang transmission line. The zero-sequence current measured at remote terminal relay was severely deviated from sinusoid after the occurrence of a single line grounding (SLG) fault near the Jindongnan side, significantly threatening protective relays based on the zero-sequence components. Therefore Laplace transformation and nodal voltage algorithm is applied on equivalent networks of zero sequences. The series capacitor of the Jindongnan side was confirmed to be the main contributor of such distortion. An improved scheme was proposed, which was to spark out the gap according to the signal sent by initial procedure immediately. The correctness and effectiveness of proposed scheme were verified by numerical simulations on RTDS.Fourthly, the parallel transmission lines are applied in the second UHV project for Huainan to Huxi, making the secondary arc current and recovery voltage not accordance with the requirements for successful auto-reclosure because of the inter-phase and inter-line capacitance. Nowadays, the shunt reactors with neutral reactor in the neutral point are always utilized to restrain the secondary arc current, especially in double-circuit model. While one of the parallel transmission lines is in maintenance state, the electrical isolation between line I and II must be maintained at all time for the safety of devices and staffs. Therefore the compensation effect is greatly weakened especially under a cross-country fault. Three optimal schemes are proposed for the double-circuit compensation model mentioned above, which focus on the accuracy, reliability and economy. The proposed schemes are verified by relevant simulations on RTDS, appropriate for normal operating state and maintenance state.At last, UHV power grid is adjacent to load center. The lack of transmission corridor and the flexible operation conditions of power system increases the multiple-circuit transmission lines, especially lines with some shared towers. A new fault locating principle is proposed in this paper, appropriate for different arrangement modes for multiple-circuit transmission lines. The most important advantage of this scheme is that the synchronous sampling is not necessary and hence a synchronous operator is introduced to eliminate the corresponding errors. Meanwhile, it uses the comprehensive positive-negative-sequence components of the voltage and current un-synchronously sampled from two ends of individual lines. The additional communication devices are unnecessary. And the transmission line equations based on distributed parameters are applied to avoid the influence caused by distributed capacitance. RTDS simulation shows the accuracy of this fault locating scheme, involving different single line faults and cross-country faults. The scheme was configured into the protection of1000kV UHV transmission lines for further improvement by engineering experiences.Oriented to project demand, five critical issues for UHV synchronous power grid are investigated comprehensively in this paper. Some valuable solving schemes are proposed and also configured in real operations. It is hopeful that the work is acceptable in the view point of engineering project and scientific research.
|
Related Dissertations
- Research on the Anti-Ice Storm in the Ultra-high Voltage (UHV) Transmission Line,TM726.1
- A Research on Single Phase Grounded Fault Locating for Power Network with Arc Suppression Coil Grounding System,TM862
- Protection of 20kV line to ground,TM862
- Research of Feeder Terminal Unit Based on Embedded System of Linux,TM76
- Methods to Measure the Fault Distance of Mix Circuit Sconstituted of Electric Cable and Stilts Research,TM755
- Research on Application of Integrated Relay Protection in Low and Medium Voltage Substation,TM774
- The Theory and Application of Novel Controlled Reactor in Long AC Transmission Line,TM47
- Research on Reactive Compensation and Secondary Arc Current for Long Distance & High Capacity Hybrid Submarine Cable Lines,TM714.3
- Study on Some Problems of Large Generator-transformer Set Protection,TM772
- Research on EHV Transimission Line Protection Based on Adaptive Residual Current Compesnsation Method and Concerned Problems,TM773
- Study on Relay Protection for UHV Transmission Lines,TM773
- Protection Principle and Device of the Distributed Zero-Sequence Protection in a Low-Resistance Grounding System,TM774
- The Investigation of High Speed Grounding Switches on Secondary Arc in 800kV GIS,TM86
- Research and Implement of Computer Network Fault Locating in Campus,TP393.18
- Research and Application of a New Kind of Fault Recording System,TM774
- Research on Suppression of Secondary Arc Current in Transmission Lines with Magnetic Valve Controllable Shunt Reactor,TM47
- Application Technology Research of Controllable Reactor in UHV System,TM47
- The Theory and It’s Application on New Type Ultra-High Voltage Controlled Reactor,TM47
- Studies in Characteristic and Countermeasure of the Secondary Arc Current in High Voltage Tranmission Line,TM726.1
- The Study of Accurately Transmission Line Fault Location Using Synchronous Sampling at Both Ends Based on GPS,TM75
- Study of Online Monitoring and Protecting Technology Power Supply Lines in the Coal Mine,TM773
CLC: > Industrial Technology > Electrotechnical > Transmission and distribution engineering, power network and power system > Power system protection > Protection devices
© 2012 www.DissertationTopic.Net Mobile
|