Dissertation > Excellent graduate degree dissertation topics show

Study on the Operating Condition of500kV Series Compensation MOV

Author: LiKaiLi
Tutor: HaoYanPeng; CaiHanSheng
School: South China University of Technology
Course: Electrical Engineering
Keywords: Series Compensation Metal Oxide Varistor System Capacity CompensationRatio Overvoltage Protection Level Short-Circuit Fault Simulation Analysis
CLC: TM862
Type: Master's thesis
Year: 2012
Downloads: 89
Quote: 0
Read: Download Dissertation

Abstract


MOV(Metal Oxide Varistor)as primary protection is the most important device of seriescompensation. MOV restricts series compensation capacitor over-voltage using its stronglynonlinear current-voltage curves in order to ensure series compensation devices safe andreliable.Operation conditions of Series compensation MOV is hardly different from MOA (MetalOxide Arrester). MOV has large surge absorption capability and high level of frequencywithstand ability. For meet engineering and technical requirements, most of seriescompensation stations utilize multi-column parallel structure. Since2008, some500kV seriescompensation stations, such as BaiSe station, PingGuo station, HeChi station, YanShanstation, belong to China Southern Power Grid Company have MOV explosions or pressurereleasing actions, which seriously affected series compensation reliable operation and safetyof workers responsible for operation and maintenance of series compensation. After analyzingthe cause of accidents by MOV disintegration and test analysis, finding MOV without dampand manufacturing issues. Simulation and system debugging can indicate MOV has largecurrent flow capacity. Therefore, the capacity of frequency withstand of series compensationMOV or selection of MOV design parameters maybe result in MOV accidents.This paper carried out the study on operating condition of500kV series compensationMOV, concerned with the capacity of frequency withstand and flow capacity of MOV afterincrease of power frequency voltage resulted from single phase grounding fault andthree-phase grounding fault. Comparatively studying on the change rules of operatingcondition of500kV series compensation MOV and several factors, such as, systemshort-circuit capacity, series compensation ratio, overvoltage protection level, fault locationand fault type. In order to illustrate the relations between MOV condition and abovementioned influencing factors, this paper built typical500kV series compensation systemmodel using EMTPE according to C.S.G.500kV series compensation practical situation, andthen comfirmed gap triggering setting value determined by external fault, and calculatedinternal fault, and finally induced this change rules guiding design of series compensationsystem and selection of MOV.

Related Dissertations

  1. Simulation Analysis on Temperature Stress of RCC Arch Dam and Its Construction Joints Design Research,TV642.2
  2. Analysis and Research of the Engine Exhaust System Simulation,U464.134.4
  3. The Research of the Air ABS on Semi-trailer Combination Vehicles,U463.526
  4. Study of Optimal Parameter Matching and Optimal Control for Fuel Cell Electronic Vehicle with Ultracapacitor,U469.722
  5. Establishment of Mechanics and Numerical Stimulation of Frost Heaving Damage of Arc-bottom Trapezoidal Canal with Concrete Lining,TV331
  6. Injection Process Analysis and Optimized Deign of MP4 Product Based on the Moldflow Software,TQ320.662
  7. Analysis and Optimization Strategy on Sunlight Environment of Urban Residential Area in Harbin,TU984.12
  8. Design and Analysis of the Hydraulic System of Quick Forging Hydraulic Press,TH137
  9. The Research and Design of Under-actuated Robot Hand with Adjustable Palm,TP241
  10. The Mechanism Study of 5·12 Wenchuan Earthquake Triggered Landslide in Yangmaoping, Maoxian,P642.22
  11. Design of Automatic Machine of Lotus Seed’s Spiltting,TS255.35
  12. Hydraulically driven high-frequency performance of reciprocating pump,TE933.3
  13. High temperature and humidity condensation of tall plant building envelope,TU111.4
  14. Thermal Performance Modeling of Power Plant Boiler System and the Application of Optimization of Coal Blending,TK227
  15. Study of Effects of Valve TrainOptimization for Engine Performance,TK403
  16. Analysis and Simulation of Piston-exhausting Air-powered Engine,TK402
  17. Optimizing Analysis of the Performance of Direct Expansion Solar Assisted Heat Pump Water Heating System,TK513
  18. A Study on the Affection of Price Mechanism to Capacity Adequacy,F426.61
  19. Design and Simulation Analysis of Resin Matrix Composites Component Based on Case,TB332
  20. The Optimization for Working Device of Jaw Crusher and the Simulation of Crushing Force,TD451
  21. Research of Supporting Technology of Deep Roadway in Jining Ⅱ Coal Mine and Application,TD353

CLC: > Industrial Technology > Electrotechnical > High Voltage Engineering > Overvoltage and Its Protection > Over-voltage protection devices
© 2012 www.DissertationTopic.Net  Mobile