Dissertation > Excellent graduate degree dissertation topics show

Study on Overvoltage and Insulation Coordination of Series Compensator

Author: ZhangXiaoBo
Tutor: LinFuChang
School: Huazhong University of Science and Technology
Course: High Voltage and Insulation Technology
Keywords: Series Compensation Metal Oxide Varistor (MOV) Regional Fault External Fault Damping Circuit
CLC: TM862
Type: Master's thesis
Year: 2013
Downloads: 23
Quote: 0
Read: Download Dissertation

Abstract


Using series compensation in large capacity AC transmission system can increase theline transport capacity and improve the balance of the reactive power. It can also greatlyimprove the security and stability of the power system. But series compensation system willbe affected by system fault. The overvoltage causing by fault can damage equipment inseries compensation, especially capacitor. Therefore, research on series compensationsystem overvoltage protection has important significance.This paper in-depth describes the overvoltage protection and control strategy based on500kV Baise series compensation. The MOV-parallel gap protection is selected as theprimary protection of Baise series compensation. The MOV is the primary protection of thecapacitor to limit capacitor overvoltage. And the spark gap is the back-up protection of theMOV and of the capacitor; Damping circuit can rapid decay the discharge current toprevent equipment damage in the discharge process. Based on this protection strategy, thispaper studies the MOV protection level and the influence factors of its energy demand. Andput forward a MOV&damping circuit parameter design method in series compensationbased on regional fault and external fault simulation.As the main protection of series compensation, MOV will be impact by the faultcurrent and absorb a great deal of energy. Considering with system operation mode, faulttype, fault location, fault moment, fault duration, overvoltage protection level, overvoltageprotection&control strategy and MOV parameters, we get the suitable MOV parametersfor Baise station.Damping circuit parameter design is another difficulty in series voltage protection.Taken into account of the damping circuit capacitor, MOV, spark gap, as well asrestrictions on its bypass switch, we get the just good damping circuit parameters to meetthe requirements of the decay rate based on the simulation analysis, while the parameters avoid the system background harmonic wave resonance point, to prevent the occurrence ofresonance.

Related Dissertations

  1. 1000kV Series Compensation Device Main Circuit Connection Mode and Hardware Research,TM761.1
  2. The Study of New Algorithm of Traveling Wave Fault Location for Transmission Line Based on Pattern Recognition,TM744
  3. High Order Taylor Series Based ATC Calculation,TM744
  4. The Research of TCSC for Improving the Power Limit under Transient Conditions in the Shannxi Power System of China,TM76
  5. High voltage distribution network reactive series compensation technology research,TM761
  6. Analysis and Suppression of Subsynchronous Oscillation in Wind Farm with Doubly Fed Induction Generator,TM614
  7. Study on TCSC Technology Suppressing Oscillations of Power System,TM712
  8. Application and Research of Inverter Technology in AC Regulator,TM464
  9. Saddle Node Bifurcation Applied to Analyse Voltage Stability in Wind Power System Including TCSC and SVC,TM712
  10. Principle and Simulation Analysis for STATCOM to Suppress Subsynchronous Oscillation,TM761
  11. Study of Traveling Wave Fault Location for Series Compensated Lines,TM762.25
  12. Identification of Transient Fault on Series Compensated Line,TM863
  13. Study on the Operating Condition of500kV Series Compensation MOV,TM862
  14. Study of D-FSC for Improving Voltage Quality in Distribution Networks,TM76
  15. Research on a Fault Current Limiter with Series Compensation Based on High Speed Switch,TM471
  16. Study on Key Technology of Economical-Type Fault Current Limiter on HV Grid,TM47
  17. Research on Management Scheme of Lines Series Engineering for Chengde-Jiangjiaying500KV Double-circuit Transmission Project,F272
  18. Study on the Tectonic in Qaidam Basin and Its Control to the Hydrocarbon Distribution,P618.13
  19. The Issues of Fault Simulation, Protection of Powerformer and Its Impacts on Power Systems Stability,TM712
  20. Simulation of the Series Compensated Power Grid and Study on UHV Transmission Line Protection,TM773

CLC: > Industrial Technology > Electrotechnical > High Voltage Engineering > Overvoltage and Its Protection > Over-voltage protection devices