Dissertation > Excellent graduate degree dissertation topics show

Study on Influence of Oil Flow to the Breakdown Characteristics of Oil-Paper Insulation under Compound Electric Field in Converter Transformer

Author: ChiMingHe
Tutor: ChenQingGuo
School: Harbin University of Science and Technology
Course: High Voltage and Insulation Technology
Keywords: converter transformer oil-flow electrification compound electric-field oil-paper insulation space charge
CLC: TM855
Type: Master's thesis
Year: 2011
Downloads: 35
Quote: 0
Read: Download Dissertation

Abstract


Converter transformer is an important equipment of UHVDC (ultro high-voltage direct current). It is the hub between AC and DC grids. Its stability directly affects to the safe operation of the system. The operating converter transformer not only withstands AC voltage, switching over-voltage and lightning impulse voltage but also DC voltage, superimposed AC-DC voltage and polarity reversal voltage. Under influence of the above voltages, there are considerable differences in the characteristics of inner electric field distribution, breakdown characteristics of insulation material, space charge accumulation and distribution, oil-flow electrification between a converter transformer and a normal power transformer, which can cause abnormal discharge and breakdown of the insulation system in a converter transformer. According to the need of the industry, the breakdown characteristics of typical oil-paper insulation under compound electric field in a converter transformer was studied as follows:Firstly, the test model suitable for oil flow condition is designed. The old oil-flow electrification test system is rebuilt,which makes the test system can be joined with the new breakdown test chamber. And the oil-flow electrification test and breakdown test can be carried out under the new test system with the tunable oil flow velocity and adjustable oil temperature..Secondly, the study on oil flow electrification characteristics of oil-paper insulation under applied electric field and without applied electric field was carried out. The research result shows that the oil flow current goes up with the velocity increasing, and the current amplitude under applied electric field is higher than that without applied electric field.Thirdly, the breakdown characteristics test with different velocity is carried out under different superimposed AC-DC voltage. At room temperature, the influence of voltage waveform and velocity to the oil-paper insulation is anlysed and concluded. The research result shows that the breakdown voltage goes down with the velocity increasing and the breakdown voltage goes up at first, then goes down with the AC content increasing in compound voltage.At last, the breakdown characteristics test with different velocity is carried out under polarity reversed voltage. The research result shows that the breakdown voltage goes down at first, then rises up a little with the velocity increasing.The researching results can be referred to the operation and the insulation design of converter transformer.

Related Dissertations

  1. Based on polarization and depolarisation current law status of transformer oil-paper insulation,TM855
  2. Consider converting the DC control of AC and DC power flow method,TM721.1
  3. Converter transformer winding end analysis and optimization of the electric field,TM42
  4. Study on Degradation Assessment of Oil-Paper Insulation and Feature Extracting of Partial Discharge of Transformer Based on Chaos Theory,TM401.2
  5. The Simulation Study and Improvement of the Drift Field in TPC Detector,O572.212
  6. Electrical Properties of ZnS / silicon nanoporous pillar array heterostructure,TB383.1
  7. A Study on the Molecular Motion and Charge Storage of PVP,O633.5
  8. The Study on Oil-Flow Electrification Characteristics of Oil-Paper Insulation in Converter Transformer,TM422
  9. Study on Oil Flow Electrification Phenomena and Its Electrostatic Hazard in the Power Transformer,TM401.1
  10. ± 800kV UHVDC Transmission System commutation transformer internal fault identification and location,TM407
  11. Research on Diagnositic Method of XLPE Cables Degradation and Measurement of Space Charge,TM247
  12. Research on Field Emission Mechanism of Carbon Nanometer Films,O484.42
  13. Analysis on Moisture in Oil-paper Insulation Using Frequency Domain Spectroscopy,TM855
  14. The Study of Corona Onset Criterion of HVDC Transmission Lines,TM851
  15. Study on Deep Trap Spectrum in Polyimide Based on Photo-Stimulated Discharge,O484.5
  16. The Study of PI/CNTs Composite Material Based on Electrical Properties and Thermally Stimulated Current,TB383.2
  17. Study of Calculating Method of Transient Electrical Field in Converter Transformer’s Oil-Paper Insulation,TM42
  18. Magnetic Leakage Field Analysis and Additional Loss Calculation of Coverter Transformer,TM42
  19. Research on HVDC Control System Simulation,TM743
  20. Hybrid electric field breakdown of oil-paper insulation system and surface flashover characteristics of,TM855
  21. Study on Influence of the Breakdown Characteristic of Oil-paper Insulation in Converter Transformer under Different Temperatures,TM855

CLC: > Industrial Technology > Electrotechnical > High Voltage Engineering > High - voltage insulation technology > Insulation test and inspection