Dissertation > Excellent graduate degree dissertation topics show
Study on the Design of Viscous Damping on Reinforced Concrete Frame Structure
Author: JiaoHeZuo
Tutor: LiuHongJun;ZhangLiangPing
School: Harbin Institute of Technology
Course: Civil Engineering
Keywords: passive energy dissipation structure viscous damper nonlinear time history analysis additional damping ratio
CLC: TU375.4
Type: Master's thesis
Year: 2011
Downloads: 102
Quote: 0
Read: Download Dissertation
Abstract
|
Viscous damper is an effective method of controlling on structures. This thesis mainly aims at an actual project of a hotel at Hai Kou, which is a 10-story reinforced concrete frame structure, with 8 fortification intensity (0.30g). In that project, viscous damper is installed in the brace, acting as an energy dissipation system. Structure analysis software and finite element software are used for the following details.The actuality, the principle, and the characteristics of all kinds of controlling devices are studied. The engineering analysis software Midas/Gen and time history analysis are used to analyze the simplified three-dimensional model. Results are studied which include how maximum displacement, base shear, and drift angle of the structure perform with damping coefficient and speed index of viscous damper.For seismic design method, which formation response spectrum method, analysis of different method to calculate the additional viscous dampers for structural damping ratio. Application of finite element analysis software Abaqus consider the structure of the complex modal analysis and the viscous damper of damping for different modes of complex structures. Application of complex modal analysis method to calculate the additional structural damping ratio, and with the specifications in force decoupling method and compared, and analyze errors.
|
Related Dissertations
- Sma-viscous Damper and Its Damping Reserch of Frame Strutures,TU352.1
- Study on Seismic Performance in Mid-rise Cold-formed Steel Structure Residence,TU352.11
- Application and Research Viscous Dampers in the Structure of the Seismic Effect,TU352.1
- Seismic Response Analysis and Isolated Measure Research of Long-Span Cable-Stayed Bridges,U442.55
- Study on Seismic Response of Multi-Tower Cable-Stayed Bridges with High Piers,U442.55
- Seismic Fragility Analysis of High-Rise Buildings Considering the Influence of Viscous Damper Failure,TU973.31
- Energy Dissipation Techniques Used in Structeres’ Retrofitting,TU352.1
- Optimum Design and Verification for Structural Seismic Based on the Viscous Damper,TU352.11
- Theory and Experimental Studies Regarding Damping Effect of Viscous Damper of Clearance Hydrocylinder,TU352.1
- Performance Based Seismic Design and Analysis for Energy Dissipation Structures with Nonlinear Viscous Dampers,TU352.1
- Parameter Sensitivity Analysis of Energy Dissipation for Double Layer Cylindrical Latticed Shell,TU352.1
- Tall Building Structure’s Additional Layers Retrofitting and Elasto-plastic Analysis,TU746.3
- Study on Velocity Exponent of the Viscous Damper and Its Engineering Applications,TU352.1
- Analysis of Portal Frame Reduction of Space Truss Structures with Viscous Dampers,TU352.1
- Seismic Performance Analysis and Research for Top-Bear Ribbed Arch Bridge,U442.55
- A Preliminary Analysis Research of Seismic Isolation Design for Continuous Girder Bridge in Severe Earthquake Region,U442.55
- Analysis on Earthquake Resistance of CFST Arch Bridge and on the Setting of Viscous Dampers,U442.55
- Study on the Seismic Responses and Shock Absorption Technique of Liede Self-anchored Suspension Bridges,U448.25
- Study of Seismic Vibration Control for a Large Opening Grid Structure with Viscous Damper,TU352.1
- The Dmaping Effect Analysis of a Large Cantilevered Truss Structures,TU352.1
CLC: > Industrial Technology > Building Science > Building structure > Concrete structure,reinforced concrete structure > Reinforced concrete structures > Frame
© 2012 www.DissertationTopic.Net Mobile
|