Dissertation > Excellent graduate degree dissertation topics show
Design of Wireless Medical Liquid-level Monitoring and Warning System Based on RF Technology
Author: ZhuJiangBo
Tutor: WeiPingJun
School: Zhongyuan Institute of Technology
Course: Signal and Information Processing
Keywords: RF technology urine volume mornitoring STC89C52 nRF905
CLC: TP274
Type: Master's thesis
Year: 2012
Downloads: 26
Quote: 0
Read: Download Dissertation
Abstract
|
Urine volume is one of the most important indicators which can reflect body tissueperfusion and fluid balance. In clinical work, they are critical evidences for medicalworkers in diagnosing patient condition and formulating treatment program. Traditionalmethods used in monitoring urine volume are mostly human observation methods,which may not only increase workload of medical workers, but also be easy to makemistake for delayed observation, even cause medical accidents. With the development ofwireless communication technology, RF transmission technology is widely used in allaspects of life, including medical field. RF technology is with the advantages of flexibleused, maintainable and scalability, also construction easily, therefore, to design a medicalurine volume monitoring and warning system based on RF technology is of greatsignificance to reduce medical staff’s workload and improve the effect of monitoring.This paper first demonstrated the necessity and feasibility of the designing ofwireles urine volume monitoring system based on RF technology, and then, described theoverall framework of the system. And then, described the components selection andhardware design, such as the selection and design of the sensor, RF905transceivermodule control and the design of the alarm and display circuit.Software of the system is written by C language, every part of the program waswritten in modular and structuered programming ideas. The software portion of thispaper focuses on the RF905control code, and then describes the operation process of thesystem ware.The experiments show that each subsystem of this system can work properly, suchas the sensor could monitoring urine level points effectivly. The tests of RF905 communication show that the effective transmission distance is more than50meters.This design provides a practical solution for the automatic mornitoring of urinevolume, and laid the foundation for its future application.
|
Related Dissertations
- The Study of Mine Gas Monitoring System Based on Wireless Sensor Networks,TN929.5
- Transient field key technologies in wireless sensor networks,TN929.5
- Based on Wireless Communication Voltage Transformer Loss of Secondary Load Test Technology Research,TM451
- Research and Implementation of Leaky Feeder Communication System Based on Digital Communication,TN914.3
- Research and Design of a Wireless Humiture Measuring and Controlling System of Granary Based on NRF905,TP274
- RFID data cleaning treatment strategies and algorithms,TP391.44
- The Development of the Multi-functional Temperature Detection System Based on Wireless Transmission,TP274
- Application Research on Substation Intelligent Inspection System in ChengDe Power Supply Company,TM63
- Study and Design of the Intelligent Control System for Power Line Inspection Robot,TP242
- The Research and Design of Wireless Open Air Mine Remote Monitoring System Based on Embedded Web,TP277
- The belt conveyor malfunction wireless monitoring system,TH222
- Design and Development of Wireless Lighting-Control Basedon NRF905 and Effect Showing,TP273.5
- The Research on Mobile Payment Based on 2.4G RF Technology,TP391.44
- The Design of Control System of Amoeba-like Robot,TP242
- Design and Realization of Wireless Intelligent Home Monitoring System Based on GPRS,TP277
- Research on Operation Data Acquisition System for Motor Based on Wireless Technology,TM306
- Design of Low-Power Consumption in Plate Digital Flowmeter and Study on RF Wireless Communication System,TH814
- Design of Downhole Monitoring System Based on SOPC Technology,TP274.4
- The Design and Implementation of Environmental Temperature Monitoring Robot,TP242
- Design of Data Acquisition System in Temperature and Wireless Transmission Based on nRF905,TP274.2
- Research and implementation of S-band RF transceiver front-end,TN859
CLC: > Industrial Technology > Automation technology,computer technology > Automation technology and equipment > Automation systems > Data processing, data processing system
© 2012 www.DissertationTopic.Net Mobile
|