Dissertation > Excellent graduate degree dissertation topics show

Design and Adjustment for Time-Domain Optical Coherence Tomography Imaging System in Anterior Segment and Its Application

Author: CaiShouDong
Tutor: LiZuo;HeYongHong
School: Fujian Normal University
Course: Optical Engineering
Keywords: Optical coherence tomography Fast scanning optical delay line Anterior segment Image correction
CLC: TP391.41
Type: Master's thesis
Year: 2010
Downloads: 24
Quote: 1
Read: Download Dissertation

Abstract


Optical coherence tomography ( Optical Coherence Tomography , OCT ) is a non-contact, non-invasive detection of new optical imaging technology, with high resolution, high sensitivity , and so on . OCT imaging system near-infrared light source can be used to measure the human body , and thus will not cause damage to human tissue , no damage tomography has a great prospect in the field of biomedical imaging , particularly in ophthalmology detection . Due to the special structure of the human eye , light easy access to OCT technology has a good prospect of application in ophthalmology . This paper focuses on the theory of fiber -based time-domain optical coherence tomography system , described a method for the detection of human anterior segment OCT system design . The first chapter describes the overview of the development of the OCT technology and a wide range of applications of OCT technology field ; Chapter II then introduced the principle of the time-domain OCT technology and fast scanning optical delay line technology, and theory the probing depth analysis of the system , the signal-to-noise ratio and other key parameters , which demonstrates the possibility of the system used in the detection of anterior segment tomography . Chapter Intro anterior segment OCT the various components of the system , including the sample arm and the reference arm , the coupler , the detection circuit . The fourth chapter describes the system resolution and signal-to-noise ratio test , anterior segment OCT images , analyze the reason of the anterior segment image distortion and its corresponding image correction method and calibration measuring corneal thickness , anterior chamber angle width and so on. The system uses a broadband light source with a center wavelength of 1310nm , designed based on the fast scanning optical delay line phase-modulated optical coherence tomography ( OCT ) system . And use self-developed scanning probe human anterior segment tomography images , to provide a more accurate tool for the quantitative measurement of human anterior chamber structure information , to pave the way for the clinical application of the anterior segment OCT system .

Related Dissertations

  1. Optical Coherence Tomography to Investigate Optical Properties of Blood during Coagulation,R318.51
  2. The Analysis of the Retinal Thickness in Refractory Amblyopia Eyes,R777.44
  3. Doppler spectral domain optical coherence tomography imaging algorithm research,TP391.41
  4. Research on the Optical Properties of Triangular Plate-like Au/Ag Nanoparticles and Their Applications in Optical Bio-imaging,O482.3
  5. Path Length Coded Coherence Combination for OCT Three-dimensional Superresolution,TP391.41
  6. Spectral domain OCT retinal imaging technology experimental study,TP391.41
  7. Investigation of Macularmicrostructure Afterretinal Detachment with Spectral Domain Optical Coherence Tomography,R774.1
  8. Development of All Fiber High Speed Time-domain OCT System,TN253
  9. The Relationship between FD-OCT Structure and Visual Field Function in Glaucoma,R775
  10. Optical coherence tomography in pituitary tumor,R736.4
  11. Investigation of Retinal Nerve Fiber Layer Changes in Different Stage of Type Ⅱ Diabetes Mellitus,R587.1
  12. Study on the Evalution of Myocardial Ischemia by Two-photon Excited Fluorescence and OCT,R541
  13. The Analysis of Influence Factor of Boshikang Soluble Granules to the Recovery Vision Function after Rhegmatogenous Retinal Detachment Urgery,R276.7
  14. Realization of the High Speed Time-domain OCT System Software and the Three-dimensional Reconstruction Software,TP391.41
  15. Research on Noise Degradation and Contour Extraction Algorithm for Eye Fundus OCT Images,TP391.41
  16. The Observation of Macular Edema with OCT and Influence on Serum Level of VEGF in Retinal Vein Occlusion Patients with TCM Therapy Based on Stages,R276.7
  17. The Study of Clinical Applications for Supra Scan Laser Photocoagulation in Diabetic Retinopathy,R774.1
  18. Relationship of the Disc Damage Likelihood Scale (DDLS), Visual Field and Optical Coherence Tomography (OCT) Parameters for Primary Chronic Angle-closure Glaucoma Optic Neuropathy and Its Clinical Therapy,R775
  19. Investigation of Traumatic Retinopathy with Spectral Domain Optical Coherence Tomography,R774.1
  20. Endoscope OCT Optical Fiber Scanning Probe Design Based on PZT and Driving Method to Achieve,TN253
  21. Expression of Vascular Endothelial Growth Factor in Experimental Anterior Segment Ischemia in Rabbits and the Research Inhibitory Effect of Suramin,R96

CLC: > Industrial Technology > Automation technology,computer technology > Computing technology,computer technology > Computer applications > Information processing (information processing) > Pattern Recognition and devices > Image recognition device
© 2012 www.DissertationTopic.Net  Mobile