Dissertation > Excellent graduate degree dissertation topics show
The Cooling Load Characteristic Analysis in the Condition of Ceiling Radiant Cooling Panels
Author: JiangYunSheng
Tutor: LiNianPing
School: Hunan University
Course: Heating,Gas Supply, Ventilation and Air Conditioning Engineering
Keywords: Ceiling Radiant Cooling Panels Load Characteristic Cooling LoadCoefficient Method Heat Balance Method Load Simulation
CLC: TU831.2
Type: Master's thesis
Year: 2013
Downloads: 35
Quote: 0
Read: Download Dissertation
Abstract
|
Ceiling radiant cooling panels have got attention widely for its energy savingeffect. However, the research of it takes example by traditional convection airconditioning at present, due to started relatively late in our country. The paperdiscusses the load characteristic of the radiation cooling system and whether thetraditional air condition design method is suitable to it.The paper introduces the ceiling radiant cooling panels&dedicated outdoor airsystem. In this system, the fresh air controls the room humidity, and the panels dealwith the most cooling load. Thus, the building energy consumption can be saved. Atpresent, the radiation cooling load calculation continues to use the design method oftraditional air system, and it uses the equivalent radiation heat exchanges method tocalculate the cooling panel areas. However, because the room features of the radiationcooling system are different from the traditional system, the cooling load is changedtoo. The paper analyses the differences between the two systems, from the aspect ofthe heat gain, the cooling load and surface temperature of the objects.Through the experimental analysis, the wall temperature distribution of the roomis obtained. It can be regarded as the study basis of the room load characteristic.Experimental results show that the wall temperature is lower than air temperatureunder the radiation cooling system, in contrast to the results of convectionair-conditioning system.The calculation method of air conditioning cooling load is analyzed. Though thecooling load coefficient method adopts the cooling load coefficient which is obtainedfrom convection air-conditioning system, and it calculates the heat quantity whichentering in the room air, it can’t apply to calculate the load of radiation coolingsystem. However, the heat balance method can be used to calculate the wall surfacetemperature and the air temperature, thus it can be used as the basis for cooling loadcalculation.The paper simulates the load characteristic of radiant cooling system byTRNSYS. The simulation shows that: the operative temperature is almost the samewhen the panel temperature of radiation cooling system is25℃and the airtemperature of convection air-conditioning system is26℃. The result can be treatedas the basis of the load characteristic studying. The paper takes the northwest wall of the room as an example, the heat flux that entered the room increases, because thewall temperature is lower in the radiant cooling system by the use of radiation heattransfer. Though the variation trend between the ceiling radiant cooling andconvection cooling is quite similar, there isn’t a curve which is relatively close at bothhigher and lower temperatures. Therefore, we can’t calculate the convection coolingload in order to get the ceiling ra diant cooling load. We should use the simulationsoftware to calculate it by heat balance method.
|
Related Dissertations
- Research on the Technology of Non-torque Loading System for Wind Turbine Drivetrain,TM614
- Wide dwarf tower cable-stayed structure parameters analysis and wide box girder shear lag effect,U448.27
- Numerical Simulation Analysis of Self-anchored Suspension Bridge’s Load Response,U441.2
- Rapid Disposal of Laminated Rubber Bearing Bridge Technology Research,U445.7
- Research on the Pivotal Technology of Motor Load Simulator,
- Load simulation device design pumping,TE933.1
- Analysis of the Stress on the Anchorage Zone of Cable-Stayed Bridge,U441.5
- The Researching of Power Load Forecasting System Based on Support Vector Machine,TM715
- Simulation and Evaluation for Operational Characteristics of Traction Substation Based on Test Data,U224
- Simulation Research on the Loading Device of Pumping Unit and Its Control System,TE933.1
- Shandong Province, the recent electricity market research,F224
- Research of Dynamic Simulation Technique on Casing Pipes Construction of Deep-water Elevated Pile Foundation Work,U445.551
- Load Simulations on High Voltage Variable Frequency Drives’ Test System,TN773
- Method for controlling electric load simulator,V351
- The giant - sub frame controlled structure the wind vibration initiative , hybrid control simulation analysis,TU352.1
- Aerodynamic Simulation of the Long-span Suspension Bridge,U441.3
- The Research Based on Laboratory Testing of Several Load Equipments Which Affect Voltage Stability,TM712
- Dynamic Research on Voltage Stability,TM712
- Study on Load Simulation Equipment of Oil Extraction Based on Electro-hydraulic Control Technology,TE93
- Design and Realization of the Analog Loading System for the Fluctuating Load,TH87
- Load Harmonics Analysis & Simulation of Different Work Conditions Based on Locomotives,U264
CLC: > Industrial Technology > Building Science > Housing construction equipment > Air-conditioning, heating, ventilation,and its equipment > Air-conditioning > Cooling and heating load calculations
© 2012 www.DissertationTopic.Net Mobile
|