Study on the Effect of Tunnel Wind on Natural Ventilation of Office Building
Author: HuShan
Tutor: ZhouZhiHua
School: Tianjin University
Course: Heating,Gas Supply, Ventilation and Air Conditioning Engineering
Keywords: underground duct system building energy conversation natural ventilation FLUENT simulation software
CLC: TU834.1
Type: Master's thesis
Year: 2012
Downloads: 3
Quote: 0
Read: Download Dissertation
Abstract
|
Energy problem is an important problem facing every country, and also one of thefour surviving problems facing human beings. The building energy consumption takesup a large proportion of total energy consumption, which concludes heating, airconditioning, ventilation, hot-water, lighting, elevator and so on. Building energysaving has already become one of important aspects for social sustainabledevelopment.Natural ventilation with underground duct system is an effective measure torealize building energy conversation. Natural ventilation can improve indoor thermalenvironment and air quality, meanwhile, save energy and promote social sustainabledevelopment, which accords with the idea of green building. Underground ductsystem equivalents to an air-soil heat exchanger, which reduces air condition energyconsumption according to stored natural cooling and heating by soil. In buildinginterior, air enters indoor through underground duct, then discharges outdoor form thetop open with the thermal buoyancy lift generated by the heat source, such as solarradiation, office equipment, and people. Outdoor air enters indoor after undergroundduct has better effect than directly enters indoor, as a result of the wall temperature islower than outdoor air temperature.The paper took an office building in Tianjin as an example. Air temperature ofcross section of underground duct, indoor temperature, temperature of skylight exportand air volume were measured. The air cooling effect in underground duct and afterentering indoor were analyzed. According to study, the relationship between airvolume and air density difference of skylight export and outdoor is determined.The FLUENT is used to simulated air cooling effect in underground duct whenoutdoor temperature was the highest in spring and autumn. The conclusions could bereached through simulation analysis: air temperature of underground duct export wasconstant with the change of outdoor temperature no matter when it was the hottest intransition season. Because of small temperature difference of skylight export andoutdoor, air volume caused by hot pressing was low, the air changes were less than1h-1. Nonetheless, indoor air cooling effect was good because the air temperature supplied was low. After the system operated for7h, soil temperature could beincreased. But when the system stopped operating, the soil temperature couldgradually recover to the original value during the following17h, which would noteffect on the next air cooling effect.
|
Related Dissertations
- The Research on the Optimization Design of Plant Natural Ventilation Based on the CFD Simulation Technology,TU834.1
- Numerical Simulation and Countermeasure for Natural Ventilation of High-rise Residential Buildings,TU834.1
- The Large-Eddy Simulation about Fitment Pollutants under Natural Ventilation,X51
- Experiment Study of Ventilation Performance of the Room Using Suspending Window,TU834
- The Application and Optimizartion of Natural Ventilation in Lijiang Station,TU834
- Research on the Natural Ventilation Design of the Primary and Secondary Schools,TU834.1
- Research of Energy Saving and Comfort of Natural Ventilation in Office Building of Shandong Region,TU834
- Studies on the Economic Incentive Policy of Residential Building Energy Efficiency,F206
- Passive solar greenhouse thermal environment experiment and numerical simulation,S625.1
- Asphalt Pavement Milling Particle Clearance Vehicles Suction Delivery System Design and Simulation,U415.5
- Study of the Indoor Concentration Distribution and Change with the Natural Ventilation by a Heat Source,X51
- Experimental Study and Umerical Simunation of Subway Tunnel Fire with Nature Ventilation,U453.5
- Experimental Study of Solar Chimney for Natural Ventilation in Buildings~2,TU834
- Residential renovation leads to indoor formaldehyde pollution control research,X512
- Study on Intensifing Interior Natural Ventilation Utilizing Solar Energy,TU834
- CFD Simulation on Natural Ventilation Assisted by Wind in Connected Rooms,TU834
- A Study of the Formal Dehyde Pollution and the Control Method in the Indoor Air of Northest Normal Univercity,X51
- Study on Energy Efficiency Evaluation for Residential Buildings in Shenzhen,TU201.5
- Research on the Influence of Louvres on Building Natural Ventilation Effect,TU834.1
- Study on Natural Ventilation of Urban Tunnel with Upper Vents,U453.5
- Investigation and Study of Formaldehyde as Indoor Air Pollution in Newly-decorated Houses,X51
CLC: > Industrial Technology > Building Science > Housing construction equipment > Air-conditioning, heating, ventilation,and its equipment > Ventilation, dust,air purification,dehumidification > Natural ventilation
© 2012 www.DissertationTopic.Net Mobile
|