Abstract


The outdoor design conditions are the basis of HVAC system design. Generally, thedetermination method of HVAC outdoor design conditions can be divided into threeissues: period of record, not-guaranteed rate statistical methods and meteorologicalelement. With the analysis about those three issues, our research aims to obtain amore rational determination method of HVAC outdoor design conditions.The standard deviation analysis and optimal climate normal were used to obtain theoptimal period of record of outdoor design conditions. Firstly, minimal period ofrecord and the corresponding optimal average k were determined respectively, thenwith the comparison of the minimal period of record and the optimal average k, theoptimal period of record of outdoor design conditions were obtained, and the methodof uniformity analysis of the distribution of those “x hour events” and comparison ofthe size of “x” was proposed to verify the superiority of the optimal period of record.The case analysis of Tianjin station show that the heating design temperature,air-conditioning design dry-bulb temperature of winter and summer is13,10and15years respectively, the air-conditioning design wet-bulb temperature is14years. Withuniformity analysis of the distribution of those “x hour events” and comparison of thesize of “x”, superiority of the period of record was verified.A TRNSYS indoor temperature calculation model was established to analyze thenot-guaranteed rate statistical method of the heating design temperature, and casestudy of Tianjin show that the indoor “not-guaranteed rate” of the “not-guaranteed5days per year” heating design temperature is just “not-guaranteed5.3hours per year”.Based on the cause of the not-guaranteed rate difference between indoor and outdoor,the comparison of the indoor “not-guaranteed rate” when solar irradiance was takeninto account or not was adopted, so necessity of the corresponding solar irradiancewas analyzed. By the analysis of building thermal process, the outdoor heatingeffective temperature was proposed and verified.When solar irradiance is not taken into account, the not-guaranteed rate differencebetween indoor and outdoor is caused just by the build ing thermal property, with thecomparison of the difference between indoor and outdoor “not-guaranteed” hourswhen the mean duration of meteorological variables is different, the suitable mean duration of meteorological variables of heating design temperature was analyzed, andfound the most suitable mean duration of meteorological variables of heating designtemperature is the non-overlapping two days.

Related Dissertations

  1. The Decadal to Centennial Variability of China Climate in the Last2000Years and It’s Relationship with Global Climate,P467
  2. Effects of Climate Change on Drought and Flooding Disasters in China,S42
  3. The Campanulaceae reproductive biology research,S644.9;S682.19
  4. Regional Building Energy Demand Analysis Based on Regulatory Plan,TU83
  5. Comprehensive Performance Analysis of the CCHP System,TU83
  6. Research on the Solar Energy-Air Source Heat Pump Double Heating Systems and Ventilation System of Bulk Curing Barn,TU83
  7. Application Research on Efficient Utilization of Waste Heat in Hotel Buildings,TU83
  8. Comparative Study on Heating Modes of Residential Building,TU83
  9. Study on the Drag Reduction of Elbow and T-junction Close-coupled Pipes by PIV and CFD,TU83
  10. Study on Building Envelope Energy-saving Retrofit and HVAC System with Life Cycle Assessment Method,TU83
  11. The Applied Research of the Solar Power Thermocompression Ventilation Roofing,TU83
  12. Measurement and Simulation of Thermal Environment of Residential District,TU83
  13. The Research of Optimized Design of City District Heating and Cooling System,TU83
  14. Investigation of the Frosting Performance and Improvement of the Defrosting Method for an Air-cooler under Low Temperature Condition,TU83
  15. Optimal Planning of Distributed CCHP System in Urban Energy Environment,TU83
  16. Study on the Indoor Thermal Environment in a Large Space with Cold Air Distribution System,TU83
  17. The Study on the Thermal Response Test and Its Application,TU83
  18. CFD Analysis of Multi-blade Centrifugal Fan and Some Program Development Work about Its Preprocess and Postprocess,TU83
  19. The Simulation Study on Solar Energy-air Compound Source Heat Pump Unit,TU83
  20. Experimental Study on Deposition Velocity of Particles in Rectangular Ventilation Ducts,TU83
  21. Study on the Characteristics of Ground Thermal Response in Summer and Winter Time,TU83

CLC: > Industrial Technology > Building Science > Housing construction equipment > Air-conditioning, heating, ventilation,and its equipment
© 2012 www.DissertationTopic.Net  Mobile