Dissertation > Excellent graduate degree dissertation topics show

Dynamic Air Disinfection Effect of Intense Pulsed Light (IPL)

Author: ZhangYinPing
Tutor: LingJiHong
School: Tianjin University
Course: Heating,Gas Supply, Ventilation and Air Conditioning Engineering
Keywords: Intense Pulsed Light (IPL) dynamic air disinfection disinfection efficiency influencing factors rate of bacterial removal SPSS
CLC: TU834.8
Type: Master's thesis
Year: 2012
Downloads: 6
Quote: 0
Read: Download Dissertation

Abstract


In recent years, as an important part of indoor environment pollution, microbialcontamination gradually becomes major concerns of domestic and overseasresearchers. So the problem of microbial contamination needs to be solved urgently toimprove the Indoor air quality. As a new kind of air sterilization disinfectiontechnology, intensity pulsed light (IPL) disinfection technology was proven to have ahighly air disinfection efficiency. However, there was little research in this field athome and abroad. What’s more, these limit research didn’t put forward guidingrecommendation for practical application. Given this, this study investigated the IPLdynamic air disinfection effect and its influencing factors and then predicted theapplication of IPL dynamic air disinfection technology.Firstly, through the experimental methods, this article studied the sterilizationeffect and factors of in duct pulse light dynamic air disinfection system. The resultsshow: with the increase of velocity, the sterilization efficiency of in duct pulse lightdynamic air disinfection decreases when other factors are constant; with the increaseof relative air humidity, the sterilization efficiency of in duct pulse light dynamic airdisinfection decreases when other factors are constant; with the increase of the ductsection, the sterilization efficiency of in duct pulse light dynamic air disinfectiondecreases when other factors are constant; the smaller the microbial particles size, themore sensitive to IPL sterilization when other factors are constant.Secondly, this paper developed a mathematical model for the disinfectionefficiency and microbial particle size, velocity, duct section and relative air humiditywith the method of multivariate linear regression. Then using the mathematical modelthe bacteria removing rate of the IPL unit applied in an office was predicted and thepredicted rate was verified by the experimental data. The study results shows that theabove mathematical model and theoretical calculation can develop a relatively goodprediction for the bacteria removing rate of the IPL unit.Finally,the bacteria removing rate of IPL unit was predicted through theoreticalcalculation method. Theoretical calculations shows: when the air change rate(ACH)is equal or greater than4, the IPL unit can be applied in office building as an air cleaner to disinfect air dynamically; when the air change rate(ACH) is15, the IPL unitcan maintain the indoor microorganism concentration below500cfu/m~3in outpatientinfusion room; when the IPL sterilization device is installed at the air mixing sectionof the air handling units, it can keep the indoor microorganism concentration below2500cfu/m~3in shopping mall or supermarkets.

Related Dissertations

  1. Analysis on Floating Population’s Hukou Transfer Intention and Its Influencing Factors,C924.2
  2. State cigarette sales forecast Influencing Factors,F224
  3. The Load Research and Comprehensive Evaluation on the Agricultural Non-Point Source Pollution in Nantong,X592
  4. Study on the Variation of Soil Clay Minerals and Influence Factors in Karst Regions under Different Rocky Desertification, Southwest China,X171
  5. The Blood Glucose Control and Influencing Factors in Type 2 Diabetic Patients with Oral Hypoglycemic Agents,R587.1
  6. College Students’ Subjective Well-being and Influential Factors of the Training Path,B844.2
  7. The Research of the Medium-sized and Small Property Insurance Companies’ Profitability Promotion Strategy in China,F842.3
  8. Studies on the Habitats and Influencing Factors of Parnassius Imperator Oberthür in Xining Western Mountain, Qinghai,Q968
  9. Study of the Adaptation of Teachers’ Code-Switching in Vocational College English Classroom,H319
  10. Study on the Situation of Labor Relations, Influence Factors and Coordination Mechanisms in Small Enterprises,F276.3
  11. Research of the Technology for Recycling Molybdenum in the Mo-tailings,TD954
  12. A Study of the Obstacles and Countermeasure in Village Committee Election,D422.6
  13. Research of Wulong Coal Mine Monitored Historical Data Mining,TD76
  14. Influencing Factors of Customer Satisfaction on the Medical Training Meeting,R-2
  15. Charactertics of Root Suckers of Populus Euphratica and Influencing Factors Along the Aqikesu River Bank in Ebinur Lake Nature Reserve,S792.11
  16. The Analysis on Commercial Residential Housings Price Change Trend and Influencing Factors in Chongqing,F293.3
  17. Investigation on Nutrition/Health Knowledge and Related Behaviors of Women During the Postpartum Period in Wuhan,R173
  18. Study on Reproductive Health Status and Influencing Factors of Sexual Behavior Among Adolescents in Hubei Province,R179
  19. Research on Patent Output of Universities in China,G306;F224
  20. The performance of the real estate business relationship between customer satisfaction and,F293.3;F224
  21. Research on Carbon Dioxide Abatement Cost of Industrial Sector in China,F205;F224

CLC: > Industrial Technology > Building Science > Housing construction equipment > Air-conditioning, heating, ventilation,and its equipment > Ventilation, dust,air purification,dehumidification > Air purification
© 2012 www.DissertationTopic.Net  Mobile