Research on Loop Closing between Multiple Grounding Systems in City Distribution Network

Author: JiaHeng
Tutor: LuoLongFu
School: Hunan University
Course: Electrical Engineering
Keywords: Low resistance grounding Resonant grounding Loop closing operation Single-phase grounding fault Zero sequence current protection
CLC: TM862
Type: Master's thesis
Year: 2013
Downloads: 39
Quote: 0
Read: Download Dissertation

Abstract


The loop closing operation is one of the very important means in providing a high level power supply reliability in city distribution network, while the chosen of the neutral grounding methods will directly affect the over voltage and short-circuit current as well as the chosen of the relay protection in the short circuit fault. In china, low-resistance grounding and resonance grounding systems exist in some large and medium-sized cities and they are in the mixed operation state. This article provides a new way of analyzing the transient state of the single-phase fault in both low-resistance and resonance grounding on the basis of the previous studies. Upon this theory, the process of the loop closing operation and a single-phase fault after this have been discussed, and a comprehensive evaluation of several loop closing methods is conducted, so lead to the chosen of the best strategy.The article firstly analyzed the transient and steady state of the single-phase fault in the resonance and low-resistance grounding systems. A new type of analysis is conducted to complement the deficiency of the previous one. PSCAD/EMTDC program is used in modeling and simulating a lOkV distribution network, and the result is compared with the calculations of the conventional method and the new one. The waveform and FFT analysis comparisons proved that the new method is much more accurate than the conventional one. Some important complements are made in the analysis of steady-state during the fault, thus the theory of transient and steady state in the single-phase fault is complete.According to the actual test conditions which has two transformer substations respectively using resonance grounding and low-resistance grounding system, a model inside of PSCAD program is built. Based on the loop-closing analysis, a simuliation was made to testify the calculation of the loop-closing current, while the necessary condition for the loop-closing and the calculation of the best action time is acquired at the same time.The actual arc characteristics in a lOkV grid single-phase fault test are shown, which provides the data to model an improved Mayr-based arc model in PSCAD. The arc model parameters for both transient and steady state are derived using the Multiple Run function in PSCAD. According to the presented three kinds of loop-closing methods and using each of the arc model built before, the single-phase to ground fault is simulated. Accoding to the over voltage, the zero sequence cuurent and the influence of the relay, the best loop-closing pattern is choosed:two kinds of grounding systems should accomplish the loop-closing withing their own grounding methods, while a zero sequence cureent protection should be added in the closing point and coopertate with the protection of the original one in the low-resistance grounding side. The protection should still be useful after the loop is cut open.

Related Dissertations

  1. Discussion of Incorrect Action of Zero-sequence Current Protection in Low Resistance Grounding System in Dongguan 10kV Power Grid,TM862
  2. Detection of Faulted Transmission Line in Small Current System Based on Random Sampling and Statistics,TM862
  3. Fault Location of Radial Distribution Power Line Based on Double Terminal Traveling Wave Principle,TM755
  4. Grounding typical urban distribution network analysis and application of zero- sequence current protection,TM862
  5. Research on Detection System of Earth Faults of an Automatic Resonant Arc Suppression Coil,TM862
  6. Research of Online Insulation Monitoring System for the Power System of Ship,TM76
  7. Experimental Study on Fault Line Selection in Shizuishan Network Grounded with Arc Extinguishing Coil,TM862
  8. Study on Application of Single Phase Grounding Fault Line Selection in Small Current Neutral Grounding System in Yangjiaping Power Supply Bureau,TM862
  9. Experimental Study on Fault Line Selection in Network Grounded with Arc Extinguishing Coil,TM864
  10. Earth Fault Location for Non-solidly Earthed System Based on Transient Signals,TM862
  11. Study on the Distance Protection for Parallel Transmission Lines on the Same Tower,TM773
  12. Protection Principle and Device of the Distributed Zero-Sequence Protection in a Low-Resistance Grounding System,TM774
  13. The Research of20kV Distribution Network Adaptive Relay Protection,TM77
  14. Research on Single-phase to Ground Fault Line Detection and Location Method in Distribution Networks,TM862
  15. Research on Neutral Grounding Improvement Project of Binhai Distribution Grids,TM862
  16. Fault Line Selection and Fault Location of Resonant Grounded System Based on the Transient Characteristics,TM862
  17. Research on Fault Feeder Selection for Single-Phase Grounding Fault in Distribution Grid Based on Transient Reactive Power,TM862
  18. Research on Hybrid Grounding Run of10kV Distribution Network,TM862
  19. Application and Research of Supple Network Automation System in Chemical Enterprise,TM727.3
  20. A New Passive Fault Indicator for Locating Insulator Flashover,TM73

CLC: > Industrial Technology > Electrotechnical > High Voltage Engineering > Overvoltage and Its Protection > Over-voltage protection devices
© 2012 www.DissertationTopic.Net  Mobile