Abstract


Objective:Comparing the root canal forming ability of TF、 K3andProTaper files using cone beam CT.Methods:The resin simulated root canals was used as the experimentalmodel.Totally27samples were recruited. Before the root canal preparation,the model was scanned by cone beam CT,aftering injecting the dye.all thecanals were prepared by crown-down RCT technique. The scanning was thesame with the precious. record after root canal Preparing time、 Root canalstraightening degree of each group、 Cutting volume comparison、 Area ofresin removal and canal center transportation were calculated bymimics8.1、PhotoshopCS5、 ImageJ software.Results:1.Preparation time:The average preparation time of TF、K3、ProTaperwas33.56±1.14s、73.59±1.47s、60.65±2.32s,separately the difference amongthese groups have ststistical significane(P<0.05).2.Root canal straightening degree:TF、 K3and ProTaper,s average rootcanal curvature changes are:1.74±0.65°、5.96±1.13°、2.44±1.14°,K3groupshows significantly high degree(P<0.05).3.Cutting volume comparison:TF、 K3、 ProTaper,s average cuttingvolume are:2.26±0.76mm3、2.82±1.01mm3、6.2±2.29mm3.Similarly,K3filecut more material than the other two groups(P<0.05).4.Area of resin removal:The average cross sectional area change at2mm to the apical orifice was0.27±0.04mm~2、0.37±0.04mm~2、0.47±0.06mm~2for TF、K3and ProTaper. At3mm there are0.29±0.03mm~2、0.37±0.05mm~2、 0.53±0.07mm~2. these three groups shows significantly differences at thesetwo places. For1、4、5、6、7、8mm,there was only difference betweenProTaper and TF or K3(P<0.05).5.canal center transportation:The1、2、3mm at the root orifice of TF、K3and ProTaper is respectively:1mm0.027±0.004cm、0.09±0.004cm、0.067±0.002cm,2mm0.031±0.003cm、0.077±0.005cm、0.063±0.005cm,3mm0.031±0.003cm、0.074±0.005cm、0.051±0.003cm,TF、K3、ProTaperhave statistical difference among these groups(P<0.05);4、5mm from theapex of TF、 K3、 ProTaper is respectively:4mm0.03±0.001cm、0.034±0.001cm、0.033±0.001cm,5mm0.03±0.003cm、0.036±0.004cm、0.035±0.004cm.Conclusions:The preparation of severe bending resin simulated rootcanals by TF files takes short time、 maintains the original direction、 hadsmall deviation degree,Furthermore,the cutting quantity of material issmall.

Related Dissertations

  1. The Clinical Study of Cone-beam CT Combining with Active Breathing Control System on Lung Cancer Radiotherapy,R734.2
  2. Research and Implement of Cone-beam CT Reconstruction Based on PI-line Method,TP391.41
  3. The Three-dimensional Study of Cranifoacial Morphology in Operated Patients with Unilateral Cleft Lip and Palate,R783.5
  4. Study on Measurement Accuracy of Implant Imaging,R783.6
  5. Research on Key Technology of Accelerating Cone-beam CT Reconstruction Based on FPGA,TP391.41
  6. Hardware Design and Implementation of High Speed Pipelined DHT for Helical Cone-Beam CT 3D Reconstruction,TP391.41
  7. Alveolar Bone Deficiency Assessments of Pre-implant Sites Using Cone Beam CT,R816.98
  8. Setup Errors of Imrt for Head and Neck Cancers Measured and Analyzed by Kilo-volt Cone-beam Computed Tomography,R739.91
  9. A FPGA Based PCIE DMA Subsystem for 3D CT Image Reconstruction,TP391.41
  10. Graphics processor in the cone beam CT imaging,TP391.41
  11. Design of Storage and Transmission System for Cone-beam CT 3D Image Reconstruction,TP391.41
  12. Imaging Analysis of Maxillary Sinus Anatomy of the Chinese Han Population Based on CBCT,R322
  13. Research in Denoising and Reconstruction Acceleration Technology of Cone Beam CT,TP391.41
  14. The Study of Setup Errors for Postoperative Cervical Cancer in Image-guided Radiotherapy,R737.33
  15. CBCT Study on the Area from the Apices of Maxillary Posterior Teeth to Maxillary Sinus Floor and Mucous Cyst of Maxillary Sinus,R782
  16. Study on Cone Beam CT Reconstruction Algorithm and Its Application,TP391.41
  17. Research of Scatter Calibration Algorithm for Cone Beam Computed Tomography,O434.1
  18. High Quality Reconstruction of Cone-Beam and Fan-Beam Computed Tomography,TP391.41
  19. The Key Technique Research of Image Guided Radiotherapy on Cone Beam Computed Tomography,TP391.41
  20. CBCT and DTS radiotherapy positioning of Applied Research,R730.5

CLC: > Medicine, health > Oral Sciences > Oral medicine > Therapy
© 2012 www.DissertationTopic.Net  Mobile