As we know, it is very difficult for the upper limb disabled people to operate mouse. Thissubject designs a special mouse for them. The control source of this system is the surface EMGof temporalis muscles. Using control sources, a variety of mouse actions can be achieved.The design of this system consists of the following four aspects.1. The design of myoelectricity acquisition analog circuit and its power circuit.2. Using microcontroller, analog signals are converted to digital signals. Then a digitalfiltering process is executed.3. The wireless module will transmit the collected SEMG signal to Windows programs.4. SEMG waveform can be displayed in real time. The duty of C#program is to achievethis function. Users can train their own SEMG through the observation of theirwaveform. After that, a precise threshold value can be set up. Finally, mouse actionswill be controlled by another Windows program.
|
Related Dissertations
- Study on Effects of Garment Pressure at Lower Limbs on Sports Performance,TS941.17
- Exoskeleton system control signal analysis and processing,TN911.7
- Control of robotic arm movements transform regular surface EMG,TN911.7
- Digital Acquisition, Storage and Processing System Research for Solid-State Micro-machined Modal Gyroscope,TP274.2
- Evaluation and Treatment of Flexion Dysfunction of Trunk Muscle on the Hemiplegic Patients with Stroke,R743.3
- The Realization and Design of Supervisory System of Equipment Room Based on Embedded Linux,TP277
- Research of Multi-Sensory Myoelectric Prosthetic Hand with Hardness and Thermal Conductivity,TP242
- The Study on Visibility Monitoring and Speed Warning System on the Freeway,TP274
- SEMG Signal Processing Base on Histogram and Spectrum,TN911.72
- Research on the Technology of Siganl Conditioning and Digital Filtering of Profilometer,TG83
- Data Acquisition and Analysis of Electromyography Signal for Controlling Artificial Hand,TH789
- Design and Research of Weighting Controller Based on DSP,TP273
- Research on Portable Discharge Fault Detecting System Based on Ultraviolet Radiation,V267
- The Effect of the Guidance on Low Back Muscle after Operation of the Middle Protrusion of the Lumbar Disc Herniation,R687.3
- Research on Quantitative Batching-Weighing System,TH715.1
- Biomechanics Analysis on the Right Heel Kick Ot Taiji,G852.11
- Design and Implementation of PC104 Bus Digital Storage Oscilloscope Card Based on VHDL,TP274.2
- Design of a Communication Protocol Interface Based on Standard IEEE 1451 Applied on a Smart Sensor Using DSP,TN915.04
- Transceiver Integrated land use long pulse Doppler Instrument Research and Implementation Process,TP368.1
- Mechanical Characteristics of Knee and Activity Characteristics of Knee Muscles during Flexion and Extension at Different Hip Angles,G804.2
- Variation Characteristics of Quadriceps Femoris Fatigue on Its Reaction Time and sEMG,G804.2
CLC: > Industrial Technology > Automation technology,computer technology > Computing technology,computer technology > Electronic digital computer (not a continuous role in computer ) > External device > Input device
© 2012 www.DissertationTopic.Net Mobile
|