Dissertation > Excellent graduate degree dissertation topics show
CT imaging and spectroscopy techniques to metal artifacts MARs experimental study
Author: WangShanShan
Tutor: XuWenJian
School: Qingdao University
Course: Medical Imaging and Nuclear Medicine
Keywords: X ray computer tomography metal image artifacts spectral imaging
CLC: R814.3
Type: Master's thesis
Year: 2011
Downloads: 57
Quote: 0
Read: Download Dissertation
Abstract
|
Objective To evaluate the value of Gemstone spectral imaging with Metal Artifact Reduction System (MARs) in removing metal shadow puppet. Materials and methods The solution containing iodine contrast agent broke up into eight different concentrations (mg/ml), which was loaded into the hard plastic pipe phantom. Bore diameter of the hard plastic pipe phantom was 6 millimetres. Every tube containing contrast agent phantom, which was loaded into mould of plastics or the soft tissues of the pig with the metallic implants artifacts, was scanned by Gemstone spectral imaging or the Conventional scan. The former was to rebuilded by Gemstone spectral imaging with single Mono or Mono+MARs. The CT value of the agent tube, which was Measured with Different ways to scan, was used for multiple comparison. Evaluation methods included subjective evaluation and objectively evaluation. Results In the condition of the same CT Dose Index CT(CTDI), while the position from the metallic implants artifacts were equal or farther than 2cm and the tube concentration were 1.0mg/ml, 2.0mg/ml,5.0mg/ml or 10.0mg/ml,the CT value of the tube which was scanned by Gemstone spectral imaging with Mono+MARs and the CT value were no obvious difference. But the Conventional scan and Gemstone spectral imaging with Mono of the tube can basically remove metal shadow puppet while the position from the metallic implants artifacts were equal or farther than 4cm and the tube concentration were 1.0mg/ml,2.0mg/ml,5.0mg/ml or 10.0mg/ml. While the position from the metallic implants artifacts were equal or farther than 4cm and the tube concentration were 20.0 mg/ml or 30.0mg/ml,the CTp value of the tube which was scanned by Gemstone spectral imaging with Mono+MARs of 80Kev,100 Kev,120 Kev,140 Kev and the CTa value were no obvious difference. But the Conventional scan of and Gemstone spectral imaging with Mono of the tube can basically remove metal shadow puppet while the position from the metallic implants artifacts were equal or farther than 6cm and the tube concentration were 20.0 mg/ml or 30.0mg/ml. Conclusion The artifact of metallic implants could be reduced obviously by Gemstone spectral imaging with Mono+MARs,which created the whole new CT imaging of the metallic implants artifacts.
|
Related Dissertations
- Coupled Calculation of the Solidification Paths of Ternary Eutectic Alloys Based on Thermo-Calc,TG111.4
- Investigations of Structure and Glass Forming Abilty of Amorphous Alloys,TG139.8
- BIT Design of Computer System on Bomb Based on Radio Communication,TJ414
- Study of Automobile Ignition Coil Testing System Based on Standard LAH032.905,U472.9
- Study on Protective Effects of Apple Polyphenol on Immune System Injury Caused by γ-Ray,S661.1
- Design of Wearable Computer’ Multiprocessor Based on SOPC,TP332
- Research of Fault Injection for a Distributed System,TP338.8
- Research on Learning-Based Low-Level Vision Problem,TP391.41
- Design and Simulation of Flight Management Computer System CDU Unit in Flight Simulation,TP391.9
- Image-Guided Adaptive Radiation Therapy of Intensity-Modulated Radiation for Cervical Cancer,R737.33
- Study the Protective Value of Spect Lung Perfusion to Lung Function in Esophageal Cancer Patients Treated with Radiotherapy,R735.1
- Prediction of Pork Processing Functionalities,TS251.1
- The Research and Implementation of Lgorithms on Microcalcification Detection,R816.4
- Tetra-tert- butyl- perylene polyhedral micro-nano crystal with XANES and XEOL research,TB383.1
- Research and Development of Computer Aided Design System ramp,TP391.72
- Study of Quality Control of 64-slice CT Coronary Angiography in Diagnosis of Rheumatic Heart Disease Abstract,R816.2
- A Study on the Time-Dependent Expression of Caspase-8in Acute β-irradiated Skin Injury in Rats,R818
- Primary Study on the Radioprotection Effect and Its Mechanism of Rosmarinic Acid against Gamma Ray Induced DNA Damage,R818
- Research and Implementation of Key Techniques of Computer Wargame,TP18
- Numerical Simulation and Influence Factors of Heat Transfer Cooler,TQ021.3
- Modeling and Controlling of Cortical Signals and Pneumatic Artificial Muscles Using the Echo State Networks,TN911.7
CLC: > Medicine, health > Of Medical > Radiation Medicine > X-ray diagnostics > X-ray inspection according to the technology
© 2012 www.DissertationTopic.Net Mobile
|