Abstract


The thesis focus on the lack of tester of gas flow meters’response speed in market and the limitation of system function, suggests designing a device that test gas flow meters’response speed, which can bring out steady gas flow, that is variation frequency, variation flowrate.What’s more, the device has simple structure and integrated function, and can be easily handled.The device will mainly used in automobile field to test gas flow meters’response speed.The paper introduces the system’s mechanical design, controlling hardware and software design, and analyzes the data collected by flowmeter. At the end, gives a summary on the whole system’s function and design.The control system design mainly includes circuit design of high frequency valve’s driver, program design of USB data collection card; Mechanical structure design mainly includes system’s pipe connection, high frequency’s reconstruction by Voice Coil Motor. The software and hardware are supportive to each other.Vacuumize the liquefaction tank through the vacuum pump, vacuum degree can be detected by the barometer that connected to the export of the liquefaction tank.The square wave signal generated by control circuit can control the turn-off of the valve . Due to the atmospheric pressure, air is pressed into the liquefaction tank, meanwhile, induced by the flowmeter, we get the signal and the signal will be gathered by the USB acquisition card, and transmitted to the computer. The designing of bypass valve can produce different flow of gas. Because of the switching speed of high-frequency valve directly affect the shape of flowmeter response curve, it will lead to inaccurate measurement results, so that testers can’t make sure whether there is something wrong with the response of the flowmeter or the switching speed of the valve is too slow.We must transform its voice coil motor to improve its switching speed and make the rise and fall time of the response curve shorter.Task of the control section of the system is mainly used to writing programs for multifunction Signal Acquisition Card of MPS-010601, and we use Visual Basic6.0 to write the code. The function of the code is outputting square-wave signals of different frequencies and outputting signals of collecting flow meters, it also establishes easy and convenient interface, and this makes controlling the device easy and intuitive.Experimental results demonstrate that our device can produce air current of changing frequencies and flow rate, it also can precisely get the influence curve of all the flow meters. The device is simple and easy controlled, and is testing response speed of flowmeters with high accuracy and high efficiency.

Related Dissertations

  1. Study of Automobile Ignition Coil Testing System Based on Standard LAH032.905,U472.9
  2. Mechanism Design and Kinematic Simulation of a Celiac Invasive Surgical Robot,TP242.3
  3. The Optimization Design and Research to Wet Coal Dryer Mechinery Control System,TP273
  4. A Design Study of PLC Elevator Access Control System Based on RFID,TP273.5
  5. Design of Fuzzy PID Controller Based on FPGA,TP273.4
  6. The Research of Coal Mine Drainage Automatic Control System,TP273
  7. Application of PID Control in Networked Control System,TP273
  8. The Design of a LED Stage Lighting Control System Based on DMX+,TM923.53
  9. Analysis and Application in Automated Balace of Heating System Based on PLC Control,TU995.3
  10. The Design and Development of Sulfuric Acid-connecting Fuzzy Control System,TP273.4
  11. Speed-Sensorless Direct Torque Control System of Induction Motors’ Design and Implementation,TM343
  12. Control System Design of the Sewage Treatment Plant Project in Hainan Province Qinglan,X703
  13. Researches on Reactive Power Optimization and Voltage Control in Ningbo Grid,TM714.3
  14. Design of Inverter Control System for Low Speed and High Torque Compound PMSM,TM341
  15. Permanent magnet synchronous traction motor design analysis and Simulation Platform,TM341
  16. Research on Spraying Characteristics and Control System of Variable-Rate Spraying Device,S491
  17. Fault Diagnosis and Tolerance Research for Train Control System and Its Computer Networks,TP393.06
  18. A bank's internal control system analysis,F832.2
  19. Scrap copper smelting process control system design and implementation,TP273
  20. Complex process control system design and control strategy,TP273
  21. Communication constraints quantitative estimation system design and analysis,TP273

CLC: > Industrial Technology > Machinery and Instrument Industry > Instruments, meters > Thermal measuring instruments > Flow Meter
© 2012 www.DissertationTopic.Net  Mobile