Dissertation > Excellent graduate degree dissertation topics show
Research on Biomechanics of Artificial Hip-Host Bone System
Author: LiuShiLei
Tutor: WangChengZuo;WangDongMei
School: Shanghai Jiaotong University
Course: Mechanical Design and Theory
Keywords: artificial hip joint finite element analysis stress shielding effect micromotion interfacial stress
CLC: R687.3
Type: Master's thesis
Year: 2012
Downloads: 63
Quote: 2
Read: Download Dissertation
Abstract
|
Since the hip arthroplasty was applied in practice, the clinicalcomplications related with it had always been a key concern. At present,the main failure of the hip replacement was aseptic loosening with thecomplicated reasons. The particle produced by interfacial fretting wear wasthe dominant factor, and the stress shielding on the fixed prosthesis was theother factor. Both of the factors lead to bone dissolution and absorption,and result in the failure of artificial hip joint replacement.This dissertation is based on the two key projects“mechanical virtualhuman of China”and“design of artificial joints for Asia race”supportedby National Natural Science Foundation of China. The three-dimensionalgeometrical model and finite element analysis model of femur wereestablished and the finite element analysis on the biomechanics caused byprosthesis aseptic loosening under gait and stair climbing was made. Thecalculations related to stress shielding effect, micromotion research andjoint interfacial stress distribution. The main contents are listed asfollowing:1) The geometric model of femur was established based oncryosectional image data using medical image processing technology andreverse engineering method. Base on the geometric model of femur, thefinite element meshing model provided a basis for the subsequent researchwas also established.2) The FEA models of intact femur and the femur implanted wereestablished, and with the models the stress distribution on the femur underthe gait and stair climbing was carried out. There was no stress shieldingeffect on the femoral medial side because of the stress outward deflection, while the lateral and anterior and posterior sides of the femur had a greaterstress shielding phenomenon. At the same time, anterior and posteriorsides’stress shielding of the femur is more sensitive to the elastic modulusthan the medial and lateral sides.3) Based on the FEA femoral models implanted with differentartificial hip stems, the micromotions between femur and stem werecalculated and the micromotion distribution on the four paths was alsoobtained. In addition, the interference’s effects on the femoral primarystabilities of different stems were analyzed. The proximal micromotion islarger the distal and the medical micromotion was also smaller than theother three sides. A certain range of interference fit has a significant impacton the micromotion and greater interference fit should be given to themedical and anterior sides of the femur than the lateral and posterior sidesto reduce the micromotion.4) With the finite element analysis method, the interfacial stressdistribution between the femur and stem under gait and stair climbing wascarried out and the stress difference’s effect on femur was analyzed. Themedical and lateral axial stress was greater than the anterior and posterioraxial stress on the three stems, and meanwhile two of the stems had stressconcentration on the distal medical side, but the third stem had no stressconcentration because of the shape of stem. Large stress difference lead toserious interfacial loosening and wear was found on the interfacial medicaland lateral sides.In short, this thesis established a human biomechanical model offemur, and meanwhile the biomechanical problems related to the artificialhip failure were carried out. The results got from the finite elementanalysis could provide a theoretical basis and useful information for thedesign of the prosthesis and the postoperative rehabilitation training.
|
Related Dissertations
- Research on the Mainframe System of Powder Mixed EDM and the Craft Experiment,TG661
- EDM Electrode Wear Mechanism and Control Research,TG661
- Finite Element Analysis and Structure Optimal Design for Combined Seal at Normal Temperature and Low Temperature,TH136
- Study on the Design and Biomechanical Behaviors of Individualized Artificial Knee Joint,R318.1
- Design of Testing Equipment for Electronic Products,TN06
- Multi-pin Internal Fixation of Calcaneal Fractures in Finite Element Analysis,R687.3
- Airborne radar antenna pedestal rapid design systems research and development,TN959.73
- Nonlinear Structural Dynamics Analysis and Optimization Design on Naval Gun Driver,TJ391
- Acoustics-Structure Coupled Analysis and Its Application in Simulation of Sound Transmission in Ear,R764
- CNC lathe spindle thermal characterization,TG519.1
- Sham hose drum drive means and hydraulic system of the structure,TE973
- White Dragon Stadium instability mechanism of landslide piles,P642.22
- Behavior of Concrete Fracture and Compression Concrete Column with FRP,TU375.3
- Optimization Research of Temperature Controlling Performance for 532nm Diode Pump Solid-state Laser with Thermoelectric Cooler,TN248
- New tamping unit design and characteristics of electro-hydraulic shaker,U216.6
- Analysis of Arm Body and Study on Properties of Electro-Hydraulic System for 80T Slag Pot Carrier,TF341.4
- Harmonic analysis of structural mechanics reducer,TH132.46
- Standard infrasound generator Mechanism and Related Technologies,TB51
- Baseband chip finger -joint design and research of CNC punch press,TG385.1
- High strength aluminum alloy Mechanism and Friction Stir Welding Process,TG453.9
- 30MN hydraulic support structure and the analysis of test stand,TD355.4
CLC: > Medicine, health > Surgery > Orthopaedic Surgery ( movement system diseases,orthopedic surgery ) > Orthopedic surgery and surgery > Bone surgery
© 2012 www.DissertationTopic.Net Mobile
|