Dissertation > Excellent graduate degree dissertation topics show
Studies on Grid-Connected Dfigwind Generation System Under Grid Fault
Author: LuJiuZeng
Tutor: FuZhongWen
School: Hebei University of Technology
Course: Electrical Engineering
Keywords: wind power DFIG wind generation system grid fault transient operational performance
CLC: TM315
Type: Master's thesis
Year: 2011
Downloads: 72
Quote: 0
Read: Download Dissertation
Abstract
|
With constantly increasing of installed wind capacity, the proportion of wind power in power system gradually increase, the mutual influence between wind power and power system will be increasing. The transient performance of wind turbine generator system under grid fault will affect the safety and stability. It will also affect the stability of power system with large scale wind power integration. Therefore, researching on the transient performance of grid-connected wind generation system under grid fault has an important meaning. The researching work is a critical link to promote the technical progress of wind power.This thesis mainly focuses on the grid-connected doubly-fed induction generator (DFIG) wind generation system, and the transient operational performances under different grid faults are studied. The specific process is as follows. Firstly , the mathematical model of DFIG wind generation system has been established, which includes wind turbine、driven institutions、generator etc. Secondly, the maximum wind power tracking strategy of DFIG wind generation system has been proposed, on this basis, the control strategy has been established. The main control system is for the rotor-side converter and grid-side converter. Furthermore, this thesis analyzes common faults of power system and chooses two of the most serious fault type that influence the operation of grid-connected DFIG wind generation system. Then, the transient variable process of the generator flux and currents has been analyzed by the way of formula derivation. Finally, a simple simulation model of test system with DFIG wind generation system has been established, which is used to study the situations that mentioned above through MATLAB/Simulink.The correctness and effectiveness of the analysis achievement above has been proved through simulation study. Moreover, simulation results demonstrate that the transient operational process will be different under different faults, and protective devices will be needed if the fault is too serious to the safety of wind generation system
|
Related Dissertations
- Grid-Side Converter Control and Wind Turbine Emulator in Direct Drive Wind Power System,TM46
- The Research of Wind Power Generation System Based on DFIG,TM614
- High-Performance Ofyaw Controlsystem’s Research of Wind Power,TM315
- Including wind farm grid voltage stability studies,TM712
- Improved UPQC low voltage ride through the wind farm in the Applied Research,TM614
- AC induction motor side inverter wind turbine research,TM464
- Research on Fault Diagnosis of Transmission Network and Action Performance Analysis of Relay Protections System,TM727
- The Power System Fault Diagnosis Method Based on Hierarchical Fuzzy Petri Nets Considering Time Sequence,TP301.1
- Research on Chopper-based Full-scale Grid-connected Power Conversion Technology for Permanent Magnet Wind Turbine Generation,TM614
- Research on Reactive Power and Voltage Regulation of DFIG-based Wind Farms,TM761.1
- Research on Reactive Power Compensation and Voltage Stability of Wind Power System,TM714
- Feasibility Study of ChaYouZhong Wind Farm Phase II Project,F426.61
- Research on the Modeling and the Grid-Connected Issue of Doubly-Fed Wind Generator,TM614
- Research on Short-Term Wind Power Prediction,TM715
- Shandong Peninsula wind energy development strategy of leading low-carbon economy,F426.61
- Research on Modeling and Control of the Megawatt Level Wind Turbine,TM315
- Study on the Method of Fault Calculation and Setting Calculation about Electrified Railway Traction with V/V Transformer,TM922.3
- Research on the Control Strategy of Directly-driven PMSG-WTS Connected to the Grid,TM46
- Research on the Control of Direct-Drive Permanent Magnet Wind Turbine Generator System,TM614
- Research on Modulation Stategy for Paralled Back-to-Back PWM Wind Converter,TM46
- Reactive Power Optimization of Transmission Network with Wind-Power,TM714.3
CLC: > Industrial Technology > Electrotechnical > Motor > Generators, large the generator group ( Zonglun,) > Wind turbines
© 2012 www.DissertationTopic.Net Mobile
|