Dissertation > Excellent graduate degree dissertation topics show

Pyroelectric Coefficient Testing System with Improved Serial Port of Computer Feedback Control

Author: YangJun
Tutor: ZengYiKe
School: Huazhong University of Science and Technology
Course: Microelectronics and Solid State Electronics
Keywords: Pyroelectric coefficient Single serial-port Weak feedback algorithm for temperature control The fitting Algorithm of heating rate Automatic measurement
CLC: TN213
Type: Master's thesis
Year: 2010
Downloads: 13
Quote: 0
Read: Download Dissertation

Abstract


The pyroelectic coefficient is the most important indicator to evaluate the pyroelectric effect of pyroelectric materials. In case that there is no uniform standard for measurement of the pyroelectric coefficient, how to accurately measure the pyroelectric coefficient is critically important in the study of pyroelectric materials. The purpose of this thesis is to improve the lack of the original test system, and develop a new pyroelectric coefficient testing system with single serial port of computer feedback control for accurate evaluation of pyroelectric coefficient.The new testing system is still using the direct method, and a lot of improvements on the hardware and software have been done on the original system.Improvements of hardware are as follows: (1) designing a serial port decoding circuit to achieve the function of four-way conversion from a single serial control, (2) recalibrating the pre-conversion amplifier circuit to obtain the same positive and negative current zoom range, (3) adopting computer feedback temperature control method in replacement of the original heating control means of using the time relay, (4) redesigning the anti-jamming system to reduce interference on the measurement results.Improvements of software are as follows: (1) modifying the structure of testing softwareto achieve user-friendly computer interface, beautifying software interface, improving the software features, and achieving automatic measurement, (2) designing a targeted computer weak feedback temperature control algorithm to provide a stable uniform heating rate environment for the testing sample, (3) proposing the theory of using the change rate of the standard lithium niobate sample temperature to fit the other pyroelectric samples and make up the objection that can not measure the rate of temperature change of pyroelectric sample directly, (4) improving the current filtering algorithm and adding the error handling mechanism using the pyroelectric current. I have completed the overall commissioning of the new test system and verified the functionality of the system with the samples of lithium niobate and lithium tantalate single crystals. The testing results are consistent with internationally recognized standards. Many other types of pyroelectric materials have been measured by this new system and the results are in good agreement with the reported values from the domestic and foreign research literatures.

Related Dissertations

  1. Assessment of Fetal Urine Production Rate by Three-dimensional Ultrasonography Using VOCAL during Normal Human Gestation and in Fetuses with Congenital Heart Disease and Hydronephrosis,R714.5
  2. I DME in the CMM system development application,TH721
  3. Construction of Automatic Measurement System for GMI Effect Based on Virtual Instrumentation,TP274
  4. Research of the Laser-Scanned Measuring for the Diameter,TH744
  5. Research on Hardware of Automatic Measurement System of Transmissivity and Reflectivity,TH741
  6. Research on Errors Analysis and Precision Control in High-precision Convexity Measurement with Laser for Thin Sheet,TG801
  7. Study of the Thermodynamic Properties in Graded Ferroelectric Films,O484.4
  8. Influence of Electrodes and Structural Transition Layers on the Dielectric and Pyroelectric Properties of Ferroelectric Thin Films,TM221
  9. Lateral Size Effects on Phase Transition Properties of Ferroelectric Thin Films,O484.4
  10. The Research of Auto Orientation System of the Shield in Subway Construction,U231.3
  11. Researches on Computer-aided System for Measuring the Pyroelectric Coefficient,TP274.5
  12. Research on the Application of Endoscopic Image Feature Extraction Technology in Aeroengine Diagnosis,V263.6
  13. Flat TV features light color measurement system,TN949.1
  14. Vane thickness automatic detection system,TP274.4
  15. LCD TV features automatic light and color measurement system,TN949.192
  16. An Automatic Measure Equipment for I/V Characteristics of Light-Emitting Devices and Data Analysis,TN383
  17. Study of the Preparation and Properties of New Type PST Ferroelectric Thin Films,TN304.055
  18. Study on Dynamic Monitoring System for Deformation of Masangxi Yangtse River Bridge,U446
  19. The Study of Intigration Methods between CAD/CAM and CMM System,TP391.7
  20. Application of Image Processing Technique in calibration of Meter Precision,TP391.4

CLC: > Industrial Technology > Radio electronics, telecommunications technology > Photonics technology,laser technology > Infrared technology and equipment > Infrared optical materials
© 2012 www.DissertationTopic.Net  Mobile