Abstract


As a important electric power transmission model, the double circuit lines on the same tower have been increased, because the transmission on ability is strong, it may reduce used ground and save cost. There are 120 kinds of faults occurred in double circuit lines, for the existence of the cross country faults. It is very complex when we calculate and analyze the faults occurred in double circuit lines, so it is very significant to study the character of cross country faults in double circuit lines and bring forth a fault phase selection scheme used in double circuit lines.The six phase current on the same terminal of double lines can be contacted by fibre channel, or based on information sharing condition on smart grid, and then constitute a set of virtual current using by the current of the same phase. A new fault phase identification method is proposed, which is based on comparing the difference of the nine current. The fiber channel and the smart grid only transmit electric parameters without electrical connection, so every phase can get the electric parameters of the other phases and won’t be affected by their electric parameters.We can get the sequence current and sequence voltage of double circuit lines when its mathematics model was associated with the boundary condition of the faults. Then we analyzed the special problems in double circuit lines using the theory above. The results of analysis will support the fault phase selection scheme used in double circuit lines later. the fault phase selection is a key factor whether the protective relay will act correctly or not. Then the relations of the nine currents under cross line faults in double circuit lines are analyzed. A new fault phase identification method is proposed, which is based on nine current. This principle can do accurate actions when judging the fault between two same lines on double-circuit transmission line, and making the fibre channel and microprocessor protection apply jointly can identify whether some lines is in condition-based maintenance automatically. Phase segregated current differential protection based on fiber-optical must be used as the main protection, but differential protection will quit when channel is in fault, this paper studies phase selection of components of the new protection principle based on nine current can be used as back up protection of the differential protection,and it can be adopted as the main protection when the differential protection is resected.

Related Dissertations

  1. Fault Location Method Based on Natural Frenquencies for Power Transmission Lines and GRID,TM773
  2. Research on Protective Relay Scheme for 220kV Double Circuit Lines on the Same Tower,TM77
  3. Research on Fault Phase Selector of Protective Relay for Double Circuit Line of the Same Tower Based on Six-Sequence Component Theory,TM753
  4. Adaptive Ground Distance Protection and Its Application on the Lines Connecting Wind Farms,TM773
  5. Study on Criterion for Adaptive Reclosing of the Double Circuit Transmission Lines,TM762.2
  6. The Research on the Practical Application of Fiber-optical Protection for Transmission Lines,TM773
  7. Study on Series Compensated Transmission Lines Accurated Fault Location Based on Distributed Parameter Model,TM773
  8. Study on Selective of Short-circuit Protection of Mine High Voltage Network Based on Traveling Wave Test,TM773
  9. Optimal Comprehensive Control of Prevention and Emergency Based on DSR and Probabilistic Insecurity Measurement,TM773
  10. Study on the Transmission Line Protection of the UHV Grid,TM773
  11. Research on the Pilot Protection and the Fault Phase Selection for Double Circuit Lines on the Same Tower,TM773
  12. Analysis and Research on the Impact of Action of the Line Protection in 220kV Weak Feed System (Power),TM773
  13. Research on Non-fault Triping Criterion of High-voltage Transmission Line Based on Local Electrical Measurements,TM773
  14. Used to contain more micro-grid distribution system of protective devices,TM773
  15. Research on Current Differential Protection for Lines in Digital Substation,TM773
  16. Study of Fast Fault Detection and Isolation Technology for Smart Distribution Grid,TM773
  17. Study for UHVDC Transmission Line Protection Based on Wavelet Transform,TM773
  18. The Distance Protection Filtering Algorithm Studies of Ultrahigh Voltage Electrical Network,TM773
  19. Research of EHV Transmission Line Optical Fiber Phase Current Differential Protection,TM773
  20. Fault Location Method Based on Natural Frenquencies for Power Transmission Lines and GRID,TM773
  21. Schemes of Protection for Distribution Networks Including Distributed Generation,TM773

CLC: > Industrial Technology > Electrotechnical > Transmission and distribution engineering, power network and power system > Power system protection > Line Protection
© 2012 www.DissertationTopic.Net  Mobile