Abstract
|
Industrial CT (Computed Tomography) has an intuitive , accurate , non-destructive testing , etc. , which are widely used in aviation , aerospace, defense and other fields . Meanwhile , the theoretically industrial CT detection of objects is not its shape , material impact is rated as internationally recognized means of non-destructive testing . Based on the previous basis of the physical design of cone-beam CT . Ray source system selected 225KV X-ray machine ; detector system detector unit number of 128 × 128, unit size 1.Omm × 1.0mm detector array ; CNC system using a microcomputer , multi-axis controller , servo drive and motor structures; using ray source to the scanning center distance of 240mm, the distance of the detector to scan center for a 160mm the overall layout . The analysis results show that the CT system can better reach the default request . Image reconstruction algorithm plays an important role in the industrial CT . Research based on a number of scholars , C and MATLAB simulation experiments on the the 2D fault and cone-beam industrial CT . Single source , single detector , parallel beam scanning mode , select 128 × 128 classic Shepp-Logan head model for the reconstruction of the object , dimensional ART algorithm reconstruction prior knowledge , the initial value , different noise different projection of missing angle image quality and relaxation parameters selected . Experimental results show that the priori knowledge and a good initial value can improve the quality of the image , the number of different projections influence the selection of the relaxation parameters under different noise , uniform increase in the number of projection to to improve the missing angle scan the reconstructed image quality ; explored cone-beam CT scan image reconstruction . Experimental results show that the ray source, the scanning center , the distance between the detectors to select a reasonable distribution and projection evenly distributed in the range of 180 degrees can improve the quality of the reconstructed image , the projection angle evenly distributed at intervals of one to twice scan the first missing interval , the remaining projection is uniformly distributed in the range of angular intervals within the second missing can improve the quality of the reconstructed image in the case of a missing angle .
|
Related Dissertations
- Design of Image Inspection Subsystem of the Horizontal Industrial CT-DR,TP391.41
- The Research and Development of the Numerial Control System for Hydraulic High-speed Turret Punch Press,TG385.1
- Physical Design of a Chip on NUCSoC,TN47
- The Design of FDM Networked Control System Based on CAN Bus and Realization of G Code,TP273
- Based on DSP and CPLD design and implementation of motion control card,TP273
- NCUC-Bus fieldbus technology research and implementation,TP273.5
- Motion control card based open CNC system design and application,TG659
- Design and Research of the Rotary Head Numerical Control Bending Wire Machine,TG305
- Capacitance Tomography direct three-dimensional image reconstruction technology research,TP391.41
- Based on the ARM and Embedded Linux system prototyping CNC wire cutting,TG484
- Based on compressed sensing reconstruction algorithm,TN911.7
- The Design of Quick Detection and Data Acquisition System Base on Low-energy X-Rays,TP274.2
- Design of Data Acquisition and Transmission System for Industrial CT Based on Spartan-6 FPGA,TP274.2
- Design of Signal Acquisition System Base on Small Pixel X-RAY Liner Array Detector Card,TP274.2
- The Study of Projection Sorting and Subset Selection in Iterative Reconstruction Algorithm Based on Cone-beam CT,TP391.41
- Research and Development of System for Reconstruction and Optimization of 3D Mesh Model,TP391.41
- Study on Measurement Algorithm for Surface Area and Lumen Volume of Industrial CT Three-dimensional Images Based on C-V Model,TP391.41
- Study on Defect Detection Algorithm of Industrial CT/DR Images Based on Wavelet Transform and C-V Model,TP391.41
- Optimization of Electrical Tomography System,O441.4
- Research and Development of Three-Dimension Engraving CNC System Based on DSP and FPGA,TG659
- Development Research on Open CNC System for Twin-turret Vertical Lathe,TG519.1
CLC: > Industrial Technology > Automation technology,computer technology > Computing technology,computer technology > Computer applications > Information processing (information processing) > Pattern Recognition and devices > Image recognition device
© 2012 www.DissertationTopic.Net Mobile
|