Dissertation > Excellent graduate degree dissertation topics show

The Operating Performance Analysis of GSHP with the Heat and Moisture Transfer in Unsaturated Soil

Author: DuMeiXia
Tutor: WangJingGang
School: Hebei University of Engineering
Course: Heating,Gas Supply, Ventilation and Air Conditioning Engineering
Keywords: Ground source heat pump Ground heat exchanger Heat and moisture transfer effect Numerical solution Operating characteristics
CLC: TU831
Type: Master's thesis
Year: 2011
Downloads: 39
Quote: 0
Read: Download Dissertation

Abstract


The main line to the ground heat exchanger , heat and moisture transfer process , consider soil moisture on the ground heat exchanger heat transfer process , coupled heat and mass transfer equations , numerical solution , and analyze the different run mode , the initial moisture , initial temperature , and heat release of soil temperature field and moisture field . On this basis the operating characteristics of the ground source heat pump system to expand the theoretical and experimental studies . The main contents of this paper are as follows : 1 . Vertical U-shaped pipe heat exchanger coupled heat and moisture transfer model . The article first introduces the basic parameters and thermal parameters of the soil of this porous medium . And the porous medium heat and moisture transfer mechanism and coupled heat and moisture transfer model to elaborate . Saturated soil ground heat exchanger is one-dimensional heat and moisture transfer coupling of physical and mathematical models based on conservation of energy and mass conservation . The numerical solution of the model . The finite difference method for the construction of a mathematical model , equation discrete time nodes forward difference space node central difference implicit format ; using VB language the two sets of discrete equations coupled iterative process . 3 . Analysis of the factors influencing the process of heat transfer coupled heat and moisture . Ground heat exchanger coupled heat and mass transfer process is affected by the initial ground temperature , initial moisture , heat release and run mode . Solve the model to simulate the impact of various factors on soil temperature field and moisture field . 4 . Analytical model of ground source heat pump system is running . Correlations established for each major component of the ground source heat pump operating characteristics of the model , and fitting the system cooling capacity row calorie consumption power and system performance on the condenser inlet water temperature ( to pipe outlet water temperature ) . 5 coupled heat and moisture transfer model verification . Built in order to verify the coupled heat and moisture transfer model , experimental study of ground source heat pump operating characteristics and temperature field simulation and experimental results for two modes of operation . Show that the basic model with the experimental results , but flawed and needs to be further improved .

Related Dissertations

  1. Study of Optimal Control Strategies for Hybrid Ground-Source Heat Pump System in Wuhan,TU831.3
  2. Experimental Research and Energy-Saving Analysis of a Ground Source Heat Pupm System in Tangshan,TU831.3
  3. Numerical Simulation Study on Heat Transfer Characteristics of Ground Heat Exchangers and Seasonal Effect,TU831.4
  4. Optimization Design and Application Software Development of Ground-source Heat Pump System,TU831.3
  5. Numerical Simulation of Three Dimensional Unsteady Heat Transfer of the Ground Heat Exchanger,TK172
  6. Study on the Engineering Application of Ground Source Heat Pump,TU831.4
  7. Ground source heat pump ground heat exchanger model and experimental study of,TU831
  8. The Experiment Study on Refrigeration Operation Performance of Buried-tube Water-cooled Digital-scroll Variable Multi System,TU831.3
  9. Study on Soil Temperature of Ground Source Heat Pump Long-term Operation,TU831.3
  10. The Study on the Long-Term Cooling of the Vertical U-Tube Ground Heat Exchanger,TU831.6
  11. Research on Heat Transfer Calculation of Vertical Ground Heat Exchangers,TU831.4
  12. The Research on Optimization Design and Operation of Ground Heat Exchanger for Ground Source Heat Pump,TU831.6
  13. Research on Heating Feasibility of Single-Row Ground Source Heat Pump System in Severe Cold Area,TU831.3
  14. Pricing of Exchange Options Based on the Fractional Brownian Motion,F830.9
  15. The Non-linear Vibration Analysis of the Multi-layered Thin-walled Cylindrical Shell,O322
  16. American Option Pricing under Stochastic Market Option Model Based on Dividend and Treatment Fees,O211.6
  17. Performance Simulation and Economic Analysis on the Hybrid Ground Source Heat Pump System with Supplemental Heat Rejecter Using Water,TU831.6
  18. Research on the Ground Source Heat Pump System in Intelligent Building,TU831.6
  19. Based on the measured ground source heat pump technology and application of energy-saving,TU831.6
  20. R&D and Application of the Geothermal Response Test Device,TU831.6
  21. Research on the Monitoring Methods of Hidden Failures in Relay Protection,TM774

CLC: > Industrial Technology > Building Science > Housing construction equipment > Air-conditioning, heating, ventilation,and its equipment > Air-conditioning