Dissertation > Excellent graduate degree dissertation topics show

Research on X-ray Test Device of Mammograms Molybdenum Target Drone Based on Semiconductor Detector

Author: LiaoXuHui
Tutor: LiuChong
School: Nanhua University
Course: Detection Technology and Automation
Keywords: Mammography Molybdenum target drone X-ray semiconductor detector test device
CLC: TP274
Type: Master's thesis
Year: 2011
Downloads: 18
Quote: 0
Read: Download Dissertation

Abstract


This paper discusses the current domestic X-ray test cases of mammograms Molybdenum drone and analyzes the test item significance systematically. Combined with today’s technology background, the X-ray test device of Molybdenum drone on the theoretical basis of“continuous X-ray attenuation”has been researched. The research project involves the semiconductor detection, nuclear electronics, electronic circuit design and wireless data transmission knowledge. As a technical support, the continuous X-ray equilibrium theory points has been utilized to design a kind of excellent performance X-ray test device Molybdenum target drone.The Si-PIN photodiodes have been selected as semiconductor radiation detectors and with which the multiple semiconductor detector built in nuclear radiation detector array. The calibration factor table of test device and the output signal of detector array have been integrated and a linear interpolation method been utilized to obtain the four physical parameters: breast X-ray tube Mo drone ball voltage, dose, half-value layer and exposure time. It applies high-profile MCU as the system core, and radio frequency technology to measure wireless transmission data. The semiconductor detector has been used to measure physical parameters of X-ray Molybdenum drone conveniently. The main characteristics of the system have been reflected in low power consumption, stable performance, easy operation and real-time parameters measuring.The first chapter describes the development and research status of X-ray Molybdenum target drone. The second chapter describes the medical application basis of X-ray, the system principle and the measurement method of parameters. The third chapter analyzes function and demonstrates the design scheme. This paper has completed the design of hardware and software about system in the fourth and the fifth chapter. Finally, the system performance test and experimental data analysis have been accomplished in the sixth chapters. The paper has described the theory method, the hardware design circuit and the software design processes in detail in corresponding chapters. Overall performance of the instrument has been tested and the feasibility of the research contents been verified by the theory research and experimental analysis.

Related Dissertations

  1. Investigations of Structure and Glass Forming Abilty of Amorphous Alloys,TG139.8
  2. Study on Protective Effects of Apple Polyphenol on Immune System Injury Caused by γ-Ray,S661.1
  3. Screening, Bio-Characteristics and Biopulping Application of a High Pectin-Degrading Baeterial Strain by Ultraviolet-Ray Mutation,TS713
  4. The Clinic Value of Diffusion Weighted Whole Body Imaging with Background Body Signal Suppression (DWIBS) Compared with hPET/CT,R445.2
  5. Assessment of Carotid Atherosclerotic Plaques with Multi-slice Spiral Computed Tomography Angiography and the Correlation of Ischemic Cerebrovascular Disease,R816.1
  6. Spectral CT Characterization of Urinary Calculi : in Vitro Experience,R691.4
  7. The Comparison of Echocardiogram and X-ray on Right Ventricular Pacing Site,R541.7
  8. Research on Interstitial Lung Disorders of the Secondary Pulmonary Tuberculosis in HRCT,R521
  9. Mammographic X-ray analysis of false-negative breast cancer,R737.9
  10. 16 -slice spiral CT MPR technique in the diagnosis of appendicitis clinical value,R656.8
  11. 3.0T high-field magnetic resonance imaging of the central type lung cancer preliminary study,R734.2
  12. Lung cancer and benign lung tumor CT misdiagnosis and control study,R734.2
  13. Blue phosphorescent iridium complex dendritic Design, Synthesis and Properties,O641.4
  14. Nano Pt / SiC Preparation, Characterization and Electrochemical Catalytic Performance,TM911.4
  15. Tetra-tert- butyl- perylene polyhedral micro-nano crystal with XANES and XEOL research,TB383.1
  16. Study of Quality Control of 64-slice CT Coronary Angiography in Diagnosis of Rheumatic Heart Disease Abstract,R816.2
  17. Uniform Image Quality Achieved by Individual Tube Current Modulation in Coronary CT Angiography: Preliminary Study,R816.2
  18. A Study on the Time-Dependent Expression of Caspase-8in Acute β-irradiated Skin Injury in Rats,R818
  19. Research on 3D Visualization Algorithm of Medical Image,TP391.41
  20. The Diagnostic Value of Multi-slice Spiral CT Three-dimensional Reconstructions for Pulmonary Focal Ground-glass Opacity,R734.2
  21. Product Development Research of Rayban Based on Chinese Market,TS959.6

CLC: > Industrial Technology > Automation technology,computer technology > Automation technology and equipment > Automation systems > Data processing, data processing system