Abstract
|
The application of the central air-conditioner system has been developed quickly with emerge of high buildings and intelligent mansion in our country. For more than 60 percentage of total buildings energy consumption used up in the central air-conditioner system, people are playing more attention to energy saving in the central air-conditioner system. Based on running on the mode of constant flux system is one of characteristics of traditional central air-conditioner system. The system design and method of equipment choosing in traditional central air-conditioner system accords with calculation method of the maximum cooling and heating load based on the buildings. But the building interior’s request to cooling and heating load is in accordance with building external ambient temperature which is dynamic changes by season and day-night. So energy load request of the central air-conditioner system is dynamic changes. That is to say, that avaiable flux operating mode substitutes constant flux operating mode is an inevitable trend.Based on the analysis and comparison function of existing central air-conditioner control system for saving energy, has studied the working principle, realization function and features of it. Aiming at the problems such as system enormousness, multiple control parameters, complicated control method and application effect non-idealed, designes a central air-conditioner control equipment for saving energy which is more accurated and directly for realizing intelligent control in it. Energy saving controler is mainly part in this equipment, combining with pump frequency converter. By collecting temperature and pressure of water system, judges the changes of cooling load in central air-conditioner system. After the identification, calculation and decision by the controller, the output of controller used to control the chilled water pump and cooling water pump. So building’s request cooling capacity match with provided cooling capacity by central air-conditioner system, and realizes the purpose of saving energy.In the first chapter, there is a summary of the background and significance of research, international and domestic status, and my main work.In the second chapter, based on the analysis principle of existing variable flux central air-conditioner, a general design of variable flux control equipment in central air-conditioner for energy saving is determined. The third chapter in detail introduced hardware design of variable flux control control in central air-conditioner for energy saving. In the fourth part, in detail introduced software realization method of controller. In the fifth chapter, introduced a concrete realization method of the control equipment. The lase chapter, there is a summarization of this paper.
|
Related Dissertations
- The Electric Power Steering System,U463.4
- Transplant of Windows CE Operation System Based on ARM9,TP316.7
- The Research of Moving Object Tracking System Based on Embeded Image Process Unit,TP391.41
- Gui Design and Application Oriented to Embedded Ultrasonic Detecting System,TP274.53
- Data Collecting and Processing of Multi-Linear-CCD Visual Measuring System,TP274.2
- LXI-VXI Adapter Design,TP274
- Research on Temperature Control System for High-Performance Oven-Control Crystal Oscillator (OCXO),TN752
- Study of An Embedded Chinese Medical Therapeutic Apparatus,R197.39
- Research of Infrared Radiation Temperature Measure System Based on μC/OS-Ⅱ,TN215
- Study on DSP-based Double-wire Welding Machine and Its Human-machine Interface,TG409
- The Hardware Design of the Intelligent Camera Based on the Embedded System,TN948.41
- Body Motion Sensing Based Personal Positioning Method and System Implementation,TN95
- The Usb-based Virtual Storage on the mini6410,TP333
- Design and Implementation of Information Flow Tracking,TP368.1
- Research of Embedded System Application Interface Based on DBUS,TP368.1
- Study of Visualized Data Processing System for Computerized Flat Kniting Machine Based on ARM9,TS183
- The Design and Implementation of Monitoring System Based on Embedded Web Server in Portable Satellite Communication Earth Station,TN927.2
- 2D Graphics Accelerator Design and Implementation,TP391.41
- Research and realization of dynamic performance analysis of code in the embedded environment,TP368.1
- The Design of a Intelligent Grading System Based on S3C2440,TP368.1
- The Development of a Serial-Type LCD Based on Embedded System,TN873.93
CLC: > Industrial Technology > Building Science > Housing construction equipment > Air-conditioning, heating, ventilation,and its equipment > Air-conditioning > Air-conditioning machinery and equipment
© 2012 www.DissertationTopic.Net Mobile
|