Dissertation > Excellent graduate degree dissertation topics show

Line imaging spectrometer based on frequency domain OCT studies focusing

Author: SunChuangWei
Tutor: HuManLi
School: Northwestern University
Course: Optics
Keywords: Frequency-domain OCT Optical Coherence Tomography line-focus mode cylindrical lens
CLC: TN27
Type: Master's thesis
Year: 2009
Downloads: 214
Quote: 2
Read: Download Dissertation

Abstract


Optical Coherence Tomography (OCT) is a high resolution imaging method for the inside microcosmic structure of the sample by detecting the sample’s interference signals from back direction dispersion light with the broad band lamp-house. It is a new imaging technology coming from the combination of the Michelson interferometer and the confocal microscope. Along with the development of the OCT, traditional OCT systems can not satisfy the need of physical real-time and high-speed detecting and imaging.The purpose of this paper’s research is that for the need of faster and steadier OCT, we validate the rationality and feasibility of the high-speed and non-scanning frequency-domain OCT system which advanced and set up by us based on the line-focused mode and imaging spectrometers, and which used the low-cost and high-power LED as lamp-house, research the principle, imaging characteristics, Signal-to-Noise and the methods for eliminating the background noise. The main contents of this paper have:1. Research the principle, imaging characteristics and the SNR influencing factors of the traditional OCT systems, and analyze the components of the system.2. Research the principle and introduce the application of the imaging spectrometer; contrast this instrument with fiber-grating spectrometer; research the FD-OCT; bring forward the combination of the imaging spectrometer and the FD-OCT; Research the light source, light paths design and the adjustment process of the new system.3. Bring forward and set up the FD-OCT based on the Michelson interferometer and line-focused style with the high power LED. This system doesn’t need any scanning drive unit and can collect the data of the 8mm width sample in 1ms with the CCD detector.4. Analyze and conclude the optical characteristics of the line-focused Optical Coherence Tomography system and the system’s noise; bring forward a new method for eliminating the background noise; Do the experiment with a reflect mirror and a glass slide, use the new eliminating noise method for data processing, the results show the noise is feckly eliminated and prove the system can get the two-dimensional tomographic image without any scanning.

Related Dissertations

  1. Optical Coherence Tomography to Investigate Optical Properties of Blood during Coagulation,R318.51
  2. The Analysis of the Retinal Thickness in Refractory Amblyopia Eyes,R777.44
  3. Doppler spectral domain optical coherence tomography imaging algorithm research,TP391.41
  4. Research on the Optical Properties of Triangular Plate-like Au/Ag Nanoparticles and Their Applications in Optical Bio-imaging,O482.3
  5. Path Length Coded Coherence Combination for OCT Three-dimensional Superresolution,TP391.41
  6. Spectral domain OCT retinal imaging technology experimental study,TP391.41
  7. Investigation of Macularmicrostructure Afterretinal Detachment with Spectral Domain Optical Coherence Tomography,R774.1
  8. Development of All Fiber High Speed Time-domain OCT System,TN253
  9. The Relationship between FD-OCT Structure and Visual Field Function in Glaucoma,R775
  10. Optical coherence tomography in pituitary tumor,R736.4
  11. Investigation of Retinal Nerve Fiber Layer Changes in Different Stage of Type Ⅱ Diabetes Mellitus,R587.1
  12. Study on the Evalution of Myocardial Ischemia by Two-photon Excited Fluorescence and OCT,R541
  13. The Analysis of Influence Factor of Boshikang Soluble Granules to the Recovery Vision Function after Rhegmatogenous Retinal Detachment Urgery,R276.7
  14. Realization of the High Speed Time-domain OCT System Software and the Three-dimensional Reconstruction Software,TP391.41
  15. Research on Noise Degradation and Contour Extraction Algorithm for Eye Fundus OCT Images,TP391.41
  16. The Observation of Macular Edema with OCT and Influence on Serum Level of VEGF in Retinal Vein Occlusion Patients with TCM Therapy Based on Stages,R276.7
  17. The Study of Clinical Applications for Supra Scan Laser Photocoagulation in Diabetic Retinopathy,R774.1
  18. Relationship of the Disc Damage Likelihood Scale (DDLS), Visual Field and Optical Coherence Tomography (OCT) Parameters for Primary Chronic Angle-closure Glaucoma Optic Neuropathy and Its Clinical Therapy,R775
  19. Investigation of Traumatic Retinopathy with Spectral Domain Optical Coherence Tomography,R774.1
  20. Endoscope OCT Optical Fiber Scanning Probe Design Based on PZT and Driving Method to Achieve,TN253
  21. Design and Adjustment for Time-Domain Optical Coherence Tomography Imaging System in Anterior Segment and Its Application,TP391.41

CLC: > Industrial Technology > Radio electronics, telecommunications technology > Photonics technology,laser technology > Display Technology
© 2012 www.DissertationTopic.Net  Mobile