Dissertation > Excellent graduate degree dissertation topics show

Ultra-large Indirect Air-cooled Structure System Temperature Stress Analysis and Study

Author: XuGaoHui
Tutor: BaiGuoLiang
School: Xi'an University of Architecture and Technology
Course: Structural Engineering
Keywords: temperature effect indirect air-cooled tower solar radiation outdoor integrated converted temperature finite element stress analysis
CLC: TU831.6
Type: Master's thesis
Year: 2009
Downloads: 117
Quote: 0
Read: Download Dissertation

Abstract


In China the development of air-cooled technology of power plants has come through from small to large,from juvenility to relative maturity,and the application of indirect air-cooled technology has made a significant progress in power plants.However, with the emergence of air-cooled large units,the height of some air-cooled towers has exceeded the scope of application of conventional cooling tower in ’fuel electric plants hydraulic design specifications’,so there are many difficult problems to be solved.The air-cooled tower whose height exceeds 165 meter is called ultra-large air-cooled tower. The main control loads include earthquake load self-loading temperature load.This paper,staring from temperature load,does some analysis and exploring on the ultra-large air-cooled tower and provides some reference for the design of the ultra-large air-cooled tower.This paper chooses the proposed ultra-large indirect air-cooled tower of coal power plant for the study object.This paper detailedly analyze the temperature field under various temperature effects,mainly including season temperature,sudden temperature, sunlight temperature change,technics temperature and so on.The analysis of solar radiation,using the method of outdoor integrated converted temperature,and considering the solar illumination,the average outdoor temperature,outdoor wind speed, material property and other factors and figuring out the straight solarization surface temperature of the tower,and assuming that the straight solarization surface temperature of tower is the cosine distribution.This paper introduces reference temperature,and take the final setting temperature of concrete as the reference temperature.The temperature change of tower is based on the reference temperature,which is more in the line with the actual situation. This paper,using the finite element software ANSYS,analyzes the temperature stress of ultra-large indirect air-cooled tower under every temperate case,and contrasts them with the gravitation.From comparison finding that the reaction force of the column toe under the temperature effect is less than one-tenth of that under the gravitation.The impact of the temperature on the tower is mainly in the ring,and the greatest tensile stress of the annulus exceeds the tensile strength design value of the concrete.A disadvantage temperature distribution on the tower is the temperature difference between the outside and inside of the tower,and the temperature stress augments with the augmentation of the temperature difference.

Related Dissertations

  1. Research on the Mainframe System of Powder Mixed EDM and the Craft Experiment,TG661
  2. EDM Electrode Wear Mechanism and Control Research,TG661
  3. Research on the Structure and Characteristics of Permanent Magnetic Coupling,TH139
  4. Simulation Analysis on Temperature Stress of RCC Arch Dam and Its Construction Joints Design Research,TV642.2
  5. The Large Concrete Hydration Heat Temperature Effects Research of the Cable Stayed Bridge,U441.5
  6. The Band Structure in 2D Resonant Phononic Crystal,O735
  7. M1 of CRH2-300 Train Finite Element Analysis and Travelling Comfort,U266
  8. Study on the Influence of Various Defects on the Characteristics of Infrared Photonic Crystal Fiber,TN253
  9. Finite Element Analysis of Seismic Performance of Rc Beams Composite Strengthened with CFRP and Steel Plate,TU352.11
  10. The Research and Application of Solar Radiation’s Utilizationon East&West Ofhigh-riseresidential in Wuhan,TU18
  11. Uniform deformation laminate interlaminar stresses Numerical simulation and high-temperature creep behavior of 40Cr steel,TB33
  12. Three-dimensional angle interlock woven composites mechanical properties of low-velocity impact and Finite Element Analysis,TB332
  13. Particle reinforced copper matrix composites mechanical behavior of finite element analysis,TB331
  14. Based on a sample study of the finite element mesh model optimization,TB114
  15. Large opening pressure vessel structural finite element analysis and strength design,TH49
  16. Reinforced steel mechanical properties of concrete structures,TU398.9
  17. Capacitance Tomography direct three-dimensional image reconstruction technology research,TP391.41
  18. Painting robot design and control method of writing,TP242.3
  19. Tube heat exchanger thermal and stress analysis,TQ051.5
  20. Based on FEM / BEM walled hull structural vibration and sound radiation characteristics of,U661.44
  21. After installation of central brake transmission housing improvement , simulation and experimental study,U463.212

CLC: > Industrial Technology > Building Science > Housing construction equipment > Air-conditioning, heating, ventilation,and its equipment > Air-conditioning > Air-conditioning refrigeration technology
© 2012 www.DissertationTopic.Net  Mobile