Dissertation > Excellent graduate degree dissertation topics show
Study and Application of Double Absorption Units of WFGD
Author: WangHui
Tutor: ChenYingXu
School: Zhejiang University
Course: Environmental Engineering
Keywords: wet flue gas desulfurization process double absorption units spraying zone corrosion and scaling GGH
CLC: X701.3
Type: Master's thesis
Year: 2009
Downloads: 99
Quote: 1
Read: Download Dissertation
Abstract
Lime/Limestone wet flue gas desulfurization(WFGD) technology with high desulfurization efficiency is being applied widely recent years in our country, which exist high capital cost and operation cost and serious corrosion. By analyzing and studying the problem of original WFGD such as complicated system, high capital cost, low efficiency of unit absorption, serious corrosion and scaling in dry/wet interface ,we draw the follow innovative conclusion by test study, theoretical analysis and project application research:a. By cancelling GGH and treating with preservatives for the following duct and stuck, the capital cost is reduced by 15% and the total pressure drop is reduced 1500Pa, it has better energy saving effect and reliability.b. By adding two layers of rods in the absorber, which makes flue gas distributes uniformly and forms primary turbulence zone, the absorber which have double absorption units can gain higher unit absorption efficiency , reduce L/G by 15% when gain equal desulfurization efficiency and reduce spraying nozzles by 20% and volume of sump by 20%.c. The wing plate with inclined angel equipped above absorber inlet and pre-spraying equipment located absorber inlet ,which can decrease the inlet temperature and clean duct, can improve the corrosion and scaling of absorber inlet duct because of the returning of flue gas and strengthen the security of the system.d. By researching important parameters in spraying zone concluding the style and arrangement of spraying and optimized design of spray layer, we can draw a conclusion that the inlet pressure of eccentric nozzle should be 0.7-0.8bar, the spraying angel of nozzles located centre of spraying zone should be 120, the nozzles located at the edge which defect a angle in order to decrease the flow along wall should be 90, the particle size of nozzle should be 2000μm~2500μm, the number of layer and distance of layer should balance enology and technology.In this article, the innovation achievement that the developing absorber which has two absorption units, the gas emitting of low temperature and the preventing corrosion and scaling of system are accomplished. This achievement is applied in 300MW power unit and realize energy saving and environmental protection. At the same time, the article provide an enlightenment of the nationalization of desulfurization system.
|
Related Dissertations
- Study on the Retrofit and Optimization of Operation of GGH of WFGD in Zhujiang Power Plant,X701.3
- Research on Aging Inhibiting Corrosion and Scaling Properties of Green Water Treatment Agents in the Plants’ Recycled Water,TM621
- Acid Corrosion Phenomenon Research on Wfgd in Power Plant,X701.3
- Study on Corrosion Resistance of Q235 and Gb3091 Steel in Tianjin Geothermal Water,TG174.3
- Purification of GGH Fusion Protein and Preliminary Evaluation of Pharmacodynamical,R587.1
- Research on Antisepticize and Antiscaling for Inflowing and Gathering Well-sinking,TE983
- Offshore oilfield water injection system corrosion and scaling Situation and Countermeasures Research,TE985
- Study of Environment-friendly Tungstate-based Water Treatment Agents,TG174.42
- Analysis and Countermeasures special conditions with the failure of the process piping,U173
- The Design and Research on the Desulfurization Project in Shanghai Wujing No.2 Electric Power Plant,X701.3
- Study on the Effect of Atmospheric Pollutants Dispersion for Uninstalling GGH from FGD System,X511
- The Research and Application of Wastewater Treatment Technology in Fuxian Oilfield,TE357.61
- Optimization of Wet Flue Gas Desulphurization System in Power Plant,X701.3
- Optimization Design of Flue Gas Desulphurization System with Ammonia for CNPC and Research on Wet Stack Emission for WFGD,X701.3
- Study on Causticity of Reheated Desulfurized Gas in Thermal Power Plant,X701
- Simulation of the Corrosion and Fouling Behavior and Technology of Anticorrosion and Antifouling on Metellic Heat Transfer Surface,X703
- Study on the Mechanism of Being Blocked of GGH in Power Plants,X701.3
- The Study on Simulation for Wet Limestone-gypsum Flue-gas Desulfurization System,X701.3
- Corrosive Characteristic Research on Heat Pipe GGH after Wet Flue Gas Desulfurization in Power Plant,TG172
- The Effect of Composite Additive on the SNCR,X701
- Study of Microwave Assisted Incineration of Asphalt Flue Gas,X701
- The Electrostatic Dust Removal System Based on Microcontroller and LabVIEW,X701.2
CLC: > Environmental science, safety science > Processing and comprehensive utilization of waste > General issues > Exhaust gas processing and utilization > Desulfurization and desulfurization