Abstract
|
Power transformer electrical power system is the most important one of the master , is a complete different voltage level of electrical energy is converted hub , its operating status directly affect the safe and stable operation of the power system , and the cost is very expensive , power transformers , must be based on the need to set the appropriate protection. In the past, the differential protection as the main protection of transformers , but with the increasing complexity of the protection requirements of the correct action rate and power system , differential protection is no longer adapted to the new requirements of the times . Today , based on the principle of the protection of the equivalent circuit , the power characteristics are to get rid of the shackles of the original ideas , the differential protection alternative , but they are assumed to be equal to the leakage inductance of the transformer secondary windings , thus affecting the protection of the right action the rate of further improved. To this end , this paper is dedicated to the identification algorithm to find the three - phase leakage inductance . The paper describes the current transformer model and protection methods , including methods based on the principle of differential and some new ideas , and pointed out the advantages and disadvantages of the various methods . This paper focuses on the analysis pointed out that the assumption that the three - phase leakage inductance equal protection criterion is its rate of protection action can make a difference to improve the obstacles and based on the principle of protection of the balance equation of the equivalent circuit analysis of power transformers triangular side loop equation starting simultaneous star side of the loop equation , get a load closing time calculation of the three-phase winding leakage inductance parameter identification algorithm . In order to achieve the recognition of the three - phase leakage inductance by comparing selected the least squares method widely used today in the field of system identification and parameter estimation . In this paper, the method of least squares linear constraints recognition and identification signal interference to overcome transformer model can not be sufficient incentive caused not recognize some of its shortcomings and test data requirements . To establish transformer digital simulation and automatically mimic the true model , simulation load closing of the power transformer , and record the voltage and current data . Through the acquisition of the data analysis , the algorithm has good convergence , at the same time , also verify the correctness and accuracy of the algorithm .
|
Related Dissertations
- Research on Vector Control System of Induction Motor Based on DSP,TM346
- The magnetorheological damper mechanical properties and Gun Recoil,TB535.1
- Study of Dynamic Equivalent of Power System Based on Parameter Identification,TM712
- Study on Excitation and Speed Control System Modeling and Visualization Parameter Identification Software,TM743
- Application Based on Mode Analysis and Signal Processing in Bridge Detection,TN911.7
- Study on Engineering Drawings Vectorization,TP391.41
- Modeling and Parameter Identification for Pneumatic Control Valve Stiction,O361.3
- Structural Dynamic Characteristic Analysis and Optimization of A 5-Axis Linkage NC Machining Center,TG659
- Dynamic Characteristic Analysis and Structural Modification of a Precise Horizontal NC Machining Center,TG659
- Study on the Synthesis of Tmpde and the Measurement of Vapor-Liquid Equilibrium of the Mixture,TQ225.2
- Dynamic Test and Modal Analysis of Prestressed Reinforced Concrete Truss Beam,TU378.6
- Approach on Beam Bridge Damage Identification under Ambient Excitation,U441.4
- Construction Monitoring and Control of Tied-arch Bridge with Flying Swallow,U448.225
- The Research of Sculpture Surface Point Distribution Strategy and Error Evaluation Method,TH161
- Study of Ground Points Extraction and Curving Surface Fitting Algorithm from ALS Data,TP722
- Research and Development on Compressor Oriented Modal Analysis System,TP311.52
- Comparative Analysis of Ambiguity Resolving Method Based on LAMBDA Method,P228.4
- The Applied Study of Stochastic Element-Free Galerkin Method to Several Engineering Problems,O241
- The Research and Implementation on Traction Substation Relay Protection,TM774
- Transmission Capacity Analysis and Risk Assessment of Hebei Southern Network,TM711
- Construction Process Monitoring Methods and Practice on Cangxi Jialingjiang Super Major Prestressed Concrete Continuous Rigid Frame Bridge,U445.4
CLC: > Industrial Technology > Electrotechnical > Transformers, converters and reactors > General issues > Maintenance,repair
© 2012 www.DissertationTopic.Net Mobile
|