Dissertation > Excellent graduate degree dissertation topics show
An Analog Pre-emphasis Gradient Waveform Generator for Magnetic Resonance Imaging
Author: XieZhaoZuo
Tutor: LiZuoYing
School: East China Normal University
Course: Radio Physics
Keywords: NMR Magnetic resonance imaging Gradient Waveform Generator Analog pre-emphasis Digital potentiometer
CLC: TH89
Type: Master's thesis
Year: 2009
Downloads: 65
Quote: 2
Read: Download Dissertation
Abstract
|
Magnetic resonance imaging (MRI) is based on the high-tech performance characteristics of organisms magnetic nuclei ( protons ) in a magnetic field imaging , NMR applications . Today , magnetic resonance imaging has become one of the main tools for clinical diagnosis and basic subjects research . Gradient pulse unit is one of the core components of the MRI system , it not only from the scan speed , spatial resolution limit with the the entire MRI system performance improvement . In this paper, the spectrometer system with analog pre-emphasis function of the gradient waveform generator design , as well as the board described in the summary and outlook in the NMR experiments . The main content of the paper is as follows: The first part introduces the basic principles of magnetic resonance imaging . The basic principle and the basic principle of the magnetic resonance imaging , including magnetic resonance and , in addition, also describes some of the conventional magnetic resonance imaging used in sequence . The second part introduces the basic structure of the magnetic resonance imaging spectrometer . Including a magnet subsystem gradient subsystems , RF subsystem , signal acquisition subsystem , computer subsystem . The third part introduces the analog preemphasis gradient generator design . First introduced the original gradient waveform generator has shortcomings, and then the gradient waveform generator of the present design of the main structure and function are described and discussed . This article analog pre-emphasis function is to take advantage of the pre-emphasis circuit and digital logic control potentiometer combined to complete it to overcome the heavy workload of the traditional analog pre-emphasis , repeatability defects and poor , as well as digital pre-emphasis the delay . The fourth part of this article gradient generator performance testing , imager , system integration, and eddy current compensation experiments and imaging experiments .
|
Related Dissertations
- MRI Guoded Experimental Cryoablation of Rabbit’s Sciatic Nerve for MRI and Pathology Contrast Study,R445.2
- The Clinic Value of Diffusion Weighted Whole Body Imaging with Background Body Signal Suppression (DWIBS) Compared with hPET/CT,R445.2
- Study on the Properties of Polyphosphatases from Beef Semitendinosus and the Enzymic Reaction Systems,TS251.1
- Diffusion Tensor Imaging Study of Idiopathic Epilepsy at 3.0T High Field Magnetic Resonance Scaner,R445.2
- A Study of Wallerian Degeneration in Cortico Spinal Tract after Cerebral Infarction by fMRI,R445.2
- A Volumetric Study of External Capsule, Extreme Capsule and Inferior Frontal Gyrus White Matter in First-Episode Paranoid Schizophrenia,R749.3
- Effective active ingredient with skullcap calixarene supramolecular inclusion complexes of,R284
- Healthy Chinese central olfactory structures related to MRI volume and olfactory function with age correlation,R445.2
- 3.0T BOLD MR techniques on acute unilateral ureteral obstruction of renal damage,R693.2
- Progressive supranuclear palsy clinical and magnetic resonance imaging characteristics of,R741
- 3.0T high-field magnetic resonance imaging of the central type lung cancer preliminary study,R734.2
- MR diffusion weighted imaging in Application Value of osteonecrosis,R681.8
- Application Study on Quantitative Analysis of Diffusion-weighted Imaging and Dynamic Contrast-enhanced MRI in Thediagnosis of Breast Lesions,R445.2
- Preliminary Study of the MRI Diagnosis and Differential Diagnosis in Multiple System Atrophy , Progressive Supranuclear Palsy and IPD,R445.2
- The Application of STIR-FLAIR and T2W-SPIR for Diagnosing the Orbital Lesions: a Contrast Study,R777
- Application of Functional MR Imaging in Diagnose for Prostate Cancer,R737.25
- Comparative Study of Clicking Temporomandibular Joint Before and after Being Cured by MRI,R445.2
- Synthesis and Characterization of Two Novel Magnetic Resonance Imaging Contrast Agents,R914
- 3D-MRI Investigation on Fetal Surface Malformations Vs.2d-MRI and 3D-US,R714.5
- The Application Values of 3.0T MR Perfusion Weighted Imaging and Diffusion Tensor Imaging in Grading of Cerebral Gliomas,R445.2
- The Exploration and Application of MR Imaging in Patients with Lateral Epicondylitis of the Elbow,R681.8
CLC: > Industrial Technology > Machinery and Instrument Industry > Instruments, meters > Other instrumentation
© 2012 www.DissertationTopic.Net Mobile
|