Dissertation > Excellent graduate degree dissertation topics show

Study on Fault-Tolerant Control of Three Phase AC Variable Frequency Drive System

Author: TangShun
Tutor: GuanZhenHong
School: Southwest Jiaotong University
Course: Power Electronics and Power Drives
Keywords: cascaded multilevel carrier phase shifted SPWM neutral-shift failure diagnosis fault-tolerant control
CLC: TM921.51
Type: Master's thesis
Year: 2009
Downloads: 151
Quote: 1
Read: Download Dissertation

Abstract


Three-phase AC variable frequency drive system is widely used in industrial, commercial, aviation and other fields for its excellent sports performance and good energy-saving effects. Because the physical model of the system has nonlinear, multi-variable, strong coupling of its own characteristics, precise control of the system is difficult and vulnerable to failure. The system failures are diagnosed fast and accurately.The corresponding fault-tolerant control strategy is of great significance to improve system reliability. In this paper, multi-level inverter drive system for the study on the inverter topology between different parts of the merits of the situation, three-phase inverter-driven control strategy, focuses on the applied multi-level cascade inverter pulse width modulation control technology. When phase-shifting point of view in different ways is used, the system output performance will have different impacts, and mathematical explanation is given to start.In accordance with the three-phase AC variable frequency drive system of the division, parts of the rectifier, DC filter capacitors, the inverter and induction motor , the fault condition may occur are described and, the various parts can be used for fault diagnosis theory in detail. The study based on 9-level inverter cascade system, when the internal switch of the power module failure, all three measures were taken and the system output performance compared. By using of neutral-shift theory, the line output voltage can be re-balanced because of fault isolation device caused .With the level of failure and the power module of failure isolation, being isolated of the failure power switch will be better performance.Theory analysis and simulation on the basis of the cascaded 7-level inverter drive system for the experimental platform, the hardware design and software design is described in detail. And by fault simulation, the correctness of the theoretical study of the feasibility and system design by taking the appropriate technology for fault-tolerant control are verified.

Related Dissertations

  1. Robust Fault Estimation and Active Fault Tolerant Control for Uncertain System,TP13
  2. Networked Control System Fault Diagnosis and Fault Tolerant Control,TP273
  3. Cascaded multilevel STATCOM control system,TM761
  4. Study on Robust Diagnosis and Fault-Tolerant Control Technology for Dynamical Systems,TP13
  5. Research of Fault Tolerantand Reconfigurationalgorithm on Winged Missile with Typicalfailures,V249.1
  6. Study on Robust H_∞ Fault-tolerant Control for Parameter Uncertain Time Delay Systems,TP13
  7. Fault Tolerant Control of Networked Control Systems Based on MPC,TP273.5
  8. The Researchs for Fault Diagnosis Algorithm and Simulation Based on Sliding Mode Observer,TP277
  9. LMI-based fault-tolerant control for uncertain singular systems,TP13
  10. Fault-Tolerant Control for Descriptor System with Time-delay,TP13
  11. Research on Fault Tolerant Control of Space Optical Communication Terminal,TN929.1
  12. Research on the DSP Based Controlled Method for Frequency-variable High Voltage Device,TN773
  13. Application on High-Voltage Frequency Inverter of Boiler Fan in Power Plant,TM621.2
  14. Robust Fault-Tolerant Control for the Uncertain Nonlinear Time-Delay Switched Systems,TP13
  15. Globally Cooperative Fault Diagnosis and Fault-tolerant Control for Multi-robot System,TP242
  16. Mixed H2/H Fault-tolerant Control for Delta Operator Uncertain Systems,TP13
  17. Network Adaptive Wireless Video Transmission Algorithm for Study,TN919.81
  18. Study on Drive and Control System of Five-Phase Pmsm and Fault-Tolerant Operation,TM341
  19. The Study on Control Strategy of Cascaded Multi-level D-STATCOM,TM761.1
  20. Research on Filtering and Fault-tolerant Control for High-speed Maglev Train Suspension System,U266.4
  21. The Study of Fault Tolerant Control Method,TP13

CLC: > Industrial Technology > Electrotechnical > Electrification,electrical energy application > Electric drive ( electric drive ) > Control system > Variable frequency control system
© 2012 www.DissertationTopic.Net  Mobile