In recent years, with the air conditioning is becoming increasingly popular in a variety of building the application, the air-conditioned indoor environmental issues have become increasingly prominent, as the impact on indoor air quality ventilation caused widespread concern. The different ventilation of indoor air quality is very different. At present, the more commonly used ventilation mixing ventilation, displacement ventilation, underfloor air supply. Ventilation method which was first developed for mixing ventilation, indoor air flow is more uniform, however, the temperature stratification is not obvious, the indoor air quality is poor, could easily lead to sick building syndrome. Follow the development of the displacement ventilation, indoor air quality has been some improvement, but lower flow velocity of this ventilation mode, it is difficult to meet winter heating demand, and the need to create additional equipment for winter heating, therefore increase the initial investment of the air-conditioning system. Floor air supply is also a newly developed better ventilation, air displacement ventilation is similar, but it is easy to cause ground dust. In recent years, a new air conditioning in Sweden - collision jet ventilation system. The study, which combines the advantages of mixing ventilation and displacement ventilation, at the same time meet winter heating, is a relatively new type of ventilation. On the basis of previous studies, using fluent simulation software to simulate conditions in variable air volume and constant air volume collision jet ventilation systems and underfloor air distribution system, two air supply indoor airflow, temperature, analyzed in detail and compare simulation results of the pollutant concentration and ventilation efficiency, comfort and other factors further investigated indoor air quality and comfort. The results indicate that the variable air volume system under load from low to high, and two air supply indoor air flow gradually into mixing ventilation in the form of displacement ventilation. Compared with Underfloor Air collision jet ventilation indoor discharge carbon dioxide is less efficient, discharge benzene efficiency is higher; collision jet ventilation indoors near a vent at the hair feeling strong. Constant air volume systems, the higher the load, the two blast indoor airflow is more nearly in the form of displacement ventilation. The situation is similar in the two air supply capacity and variable air volume systems that emit carbon dioxide and benzene, indoor Hair sense of the two kinds of air supply, however, are small, and not very different.

Related Dissertations

  1. The Setting Bases of Working Pressure in LNG Systems and Orthogonal Experiment Design of Heat Exchangers,TQ051.5
  2. Study on Springback of High-Strength Steel Stamping,TG386
  3. Numerical Simulation and Experiment on Hydroforming of Cups with Controllable Radial Pressure,TG386
  4. Research on Technology and Mechanism of Joining Cemented Carbide to Carbon Steel,TG454
  5. Numerical Simulation of Film Cooling in Turbine Cascade with Non-Axisymmetric Endwall Method,V231.3
  6. High Speed Aerodynamic Convection and Coupled Heat Transfer of Complicated Bodies,V215.4
  7. The Analysis on Characteris of Vibration Source about Vertical Vibration of Surrounding Environment Induced by Rail Transit,U211.3
  8. Study on the Heat Transfer Characteristics of Particle Cluster in Circulating Fluidized Bed,TK124
  9. Numerical Simulation of SNCR Process of a 600MW Utility Boiler,TK222
  10. Numerical Simulation of Biomass Direct Reburning,TK16
  11. Numerical Simulation on Pulverized Coal Combustion Process in a 670T/H Tangential Firing Furnace,TK224.11
  12. Numerical Simulation on the Combustion Process in the Furnace of a 1000MW Lignite-Fired USC Boiler,TK224.11
  13. Study on Gas-Solid Two-Phase Flow in Spouted Beds,TK173
  14. Experimental Study and Numerical Simulation on Aerodynamic Field of Tangential Bias Swirl Burner,TK223.23
  15. Characteristic Study of Combustion in Central Reverse Flame Chamber,TK223.21
  16. Numerical Simulation and Contrastive Analysis of Labyrinth Seals and Leaf Seals,TK263.2
  17. Numerical Study on Phosphorus Distribution in Water Environment of the Three Gorges Reservoir,X832
  18. The Design and Performance Simulation of External Valve Small Displacement Pump,TE933.3
  19. Analysis of the Impact of Tailings Dam Stability under Seepage Role,TV649
  20. Study on Hydraulic Fracturing of Low Permeability Reservoir,P618.13
  21. Numerical Simulation and Experimental Study of Air-Assisted Sprayer of Orchard,S491

CLC: > Industrial Technology > Building Science > Housing construction equipment > Air-conditioning, heating, ventilation,and its equipment > Air-conditioning
© 2012 www.DissertationTopic.Net  Mobile