Abstract
|
CCD cameras, also known as a digital camera, it is the use of the CCD photoelectric imaging technology developed a new generation of the camera. In recent years , CCD camera gradually used in close-range photogrammetry , low-altitude photogrammetry . The results of the photographic measurement accuracy can meet the engineering requirements , depending on the technical parameters of the camera and data processing technology . Therefore , the technical parameters of the camera calibration is to ensure the quality of results can meet the accuracy requirements of one of the key issues . Ordinary non-metric digital camera calibration, a commonly used method is direct linear transformation (DLT) model law , the basic idea is to set up a sufficient number of control points in space , prior to determination of the spatial coordinates of each control point control point position , with the camera shooting would like conformation point coordinates and space coordinates into the equation , the internal and external orientation elements of the camera can be calculated . When considering lens distortion error , he shall add the system error correction . Enabling the camera main pitch , like the main point coordinates and optical distortion and other factors caused the system error correction calibration correction . DLT direct linear transformation camera calibration method has been developed after years of research and analysis of a large number of experts and scholars , the calibration results point accuracy of 0.35 pixels . However , the need to establish the field of high-precision control , the inconvenience to the field of photogrammetry . For that reason , we propose a new control no matter party camera self - calibration method , the relative orientation of the method , which is based on the conditions of continuous coplanar like camera calibration parameter values ??. And DLT method of camera calibration results compared to verify the reliability of the respective calibration parameters . The experimental results show that the coplanar condition calibration method is reliable .
|
Related Dissertations
- Quantitative Analysis of Pyrolysis Component of Typical Low Volatile Coal of Chinese,TQ530.2
- Study of Mechanism Using Two-Direction Pre-Stress to Control Welding Distortion and Hot Cracking,TG404
- Measurement of the Surface Impedance of the High Temperature Superconducting Thin Films with Coplanar Transmission Line,O484.5
- Research on Ionosphere Contamination of High Frequency Radar Echoes and Time-Frequency Analysis Technology,TN958.93
- Rate-distortion Optimization Based Rate Control,TN919.81
- Packet Loss Recovering Technology for Speech Transmission over Network,TN912.3
- Research on Removal Algorithm of Shadows in Image Segmentation,TP391.41
- The Research of 3D Human Motion Capture Based on Reference Points,TP391.41
- Camera Calibration and Position and Pose Detecting on Vision Measurement System of PCB,TP391.41
- Sound source directional mobile robot Methods,TP242
- Calibration and Application of Inertial Measurement Unit Based on MEMS Gyro,V241.5
- Automatic Calibration System Voltage Monitor,TM933.2
- Temperature Compensation and Auto-calibration of High-Precision Electronic Balance,TP274
- Design and realization of high-speed of the wind tunnel balance calibration software,TP311.52
- Design and implementation of the multi-channel pressure sensor auto-calibration system,TP212
- Research on 4CPFSK Baseband Signal Processing and IC Design Based on DMR Protocol,TN929.5
- High Efficiency 3D Video Representation and Coding,TN919.81
- The Research and Implement on Camera Calibration Technology Based on Trifocal Tensor,TP391.41
- Single Camera Calibration Method Based on Dual-mirror Imaging,TP391.41
- The Aerodynamic Characteristics Research of Top-mounted S-shaped Inlet Based on the Comparison of Two Different Entrance Shape,V211.48
- Study on Instrument Calibrator for Diesel Engines and Its Integrated Information Management System,TK426
CLC: > Astronomy,Earth Sciences > Surveying and Mapping > Photogrammetry and Surveying, Mapping and Remote Sensing > Non - topographic photogrammetry > Near shadow photogrammetry
© 2012 www.DissertationTopic.Net Mobile
|