Dissertation > Excellent graduate degree dissertation topics show
Experimental Study on Dynamic Performance of Air Source Heat Pump under Frosting Conditions
Author: LiuGuoWei
Tutor: YaoYang
School: Harbin Institute of Technology
Course: Heating,Gas Supply, Ventilation and Air Conditioning Engineering
Keywords: Air source heat pump Frost Dynamic performance Experimental study
CLC: TU831.7
Type: Master's thesis
Year: 2007
Downloads: 236
Quote: 2
Read: Download Dissertation
Abstract
|
With world energy structure adjustment and global sustainable development strategy put forward, there is growing emphasis on the development and utilization of clean, safe, efficient energy. Air source heat pump system electric energy as the driving force, the outdoor ambient air as cold, heat, cold, heat the object to be adjusted. This environmentally-friendly and efficient energy supply in the low energy use has a clear competitive advantage. The use of air source heat pump split type room air conditioner is very popular. But the effect of the actual operation of the air source heat pump, low temperatures and relative humidity relatively large area heating operation is still not ideal, frosting and defrosting of the outdoor heat exchanger in heating run impact on air source heat pump running in winter is an important issue. When the outdoor heat exchanger surface frost will reduce the heat transfer coefficient of the heat exchanger, to increase the flow resistance of the air-side, reducing the heating capacity of the air source heat pump. How to prevent or delay the outdoor heat exchanger frost and how to select the defrost control issues of general interest. To do this, it should be in-depth study of the law of air source heat pump frost and frost on heat pump performance. In this paper, experimental studies of air source heat pump in frosting conditions of dynamic performance, their performance in the frosting conditions was investigated experimentally explore the performance of air source heat pump outdoor heat exchanger frost affected. The evaporation temperature, the compressor suction pressure, discharge pressure, the compressor shaft power, the power of the outdoor fan, heat capacity, and other parameters are measured in experiments in different conditions and with increasing running time of the changes, on this basis, analysis of the impact of environmental parameters on the total heating capacity, energy efficiency. This provides a basis for the heat pump air conditioner defrost control and design optimization. Experimental results show that: (lt; 75%) in the low relative humidity conditions, the outdoor heat exchanger fin surface basic non-frost; stable operation of the heat pump air conditioner, the dynamic parameters did not change significantly; relative humidity higher (GT; 80%) conditions, the surface of the fins of the outdoor heat exchanger frost, and the greater the relative humidity, the the frosting phenomenon is more serious, and various dynamic parameters corresponding changes significantly. Also in the harsh conditions of relative humidity greater than 95%, the frost of the outdoor heat exchanger of a heat pump air conditioner is very serious, and very rapidly, obviously a variety of dynamic parameters change, the heat pump heating capacity and COP value decreased rapidly; It is necessary to study them in depth in the harsh conditions frosting and defrosting of the heat pump. Part of the subject \
|
Related Dissertations
- Zinc kiln residue of dry exhaust gas emission reduction and waste heat recycling research,X756
- The Study of Yeast Frost-resistance and Application in Frozen Dough,TS213.2
- Studies on Evaluation of Frost Resistance of Winter Wheat Varieties and the Correlative Physiological Characteristics,S512.11
- Experimental Study of GUI QIN MISTURE on Adriamycin-induced Nephropathy in Rats,R285.5
- Gas and coal dust explosion characteristics of coexistence and Communication Research,TD712
- The Research and Manufacture on A New Type Heat Pump Water Boiler with Two-stage Heating,TH38
- The Experimental Research on Process Evaluation Applying for the General Course of Breaststroke Teaching in Harbin University,G861.1
- The Use of Incentive Strategies on the Study of the Impact of Sports Participation in Primary School Physical Education,G623.8
- An Experimental Study on Teaching Model of "Chain Combination" of the Convention and the Option of High School Physical Education,G633.96
- The University Body Teaches Specialized Speed Skating Pu to Repair in the Class to Apply Therepresentation Training Method the Experimental Study,G862.1
- The Pueraria bulk wine injury rat serum sex hormone levels,R285.5
- The Theoretical and Experimental Research on the Collocated MIMO Detection,TB566
- Experimental Study of the Performances of Air Filter Materials for Fine Particles Removal Utilized in Residential Buildings,TU834
- Design and Experimental Study of High Performance Miniature Channel Heat Sinks,TK124
- Research on Topology and Control Algorithm of Single-phase Boost Power Factor Correction Converter,TM461
- Investigation on Vortex-Induced-Vibration of Flexible Risers with Buoyancy Modules,TB123
- Small air-source heat pump and solar water-heating properties of,TU18
- Comparison of corporate charitable donations Effect,F224
- DDT -based power control mechanism of warhead,V271.41
- Henan typical low-temperature ceramic sand curing mechanism and technology research,U414
- Shandong Institute of Physical Education Teaching and Training Basketball physical experimental study,G841
CLC: > Industrial Technology > Building Science > Housing construction equipment > Air-conditioning, heating, ventilation,and its equipment > Air-conditioning > A variety of air conditioners
© 2012 www.DissertationTopic.Net Mobile
|