Dissertation > Excellent graduate degree dissertation topics show
Data Analysis in UHF PD Monitoring for Power Transformers
Author: WangJie
Tutor: LiChaoZuo
School: Huazhong University of Science and Technology
Course: Water Resources and Hydropower Engineering
Keywords: power transformer partial discharge ultra-high-frequency pulse extraction classification and recognition
CLC: TM41
Type: Master's thesis
Year: 2010
Downloads: 71
Quote: 0
Read: Download Dissertation
Abstract
|
During the operation of power transformers, insulation deterioration is still the major fault. Partial discharge (PD) is one of the prime reasons to cause insulation deterioration occurring inside power transformers. The PD on-line monitoring can be used to judge the insulation situation of power transformers accurately and timely. It’s valuable to prevent accident faults in power transformers and insure stable performance of power system. Ultra-high-frequency (UHF) PD monitoring approach is focused on recent years because of its effectiveness to avoid noises.In order to solve the difficulties in pulses extraction and classification of the on-line monitoring system in power transformers, a research on data analysis and knowledge discovery of UHF PD monitoring system in power transformers was conducted using the raw data obtained from the on-line monitoring system of 251B, 1B, 14B, 18B transformers in Gezhouba Hydro Power Plant.Firstly the theory of UHF PD on-line monitoring in transformers and signal characteristics were studied, and an overview of anti-interference measures and data analysis methods in UHF PD monitoring system were given. Then referring to the process of knowledge discovery, the target datasets were established on the basis of the structure and principle of the monitoring system. After filtering and de-noising of the datasets, a method based on sliding window and energy threshold was used to extract the information of a single pulse. In the end, the general characteristics of pulses under different conditions of the transformer unit were summed up on the platform of the Optimal Maintenance System for Hydro power plants(HOMS).Through the analysis of the typical pulses, an algorithm for pulses classification and recognition based on pulse width, polarity and distribution characteristics was designed and implemented. The results showed that this algorithm had the characteristics of less calculation and high efficiency, and was able to classify and identify kinds of typical pulses effectively.
|
Related Dissertations
- Design and Simulation of UHF RFID System Based on the Protocol of EPC C1G2,TP391.44
- Study on the Mechanism of Partial Discharge Emitting Ultrasonic Wave and Propagation Property Within Power Transformers,TM855
- Optimal Power Flow Control Based on Electronic Power Transformer,TM76
- Study of Ultrasonic Location for Partial Discharge in Transformer,TM855
- Transformer equivalent circuit model based on the process of computing and software development wave,TM41
- Power transformer stray loss and thermal issues related to the calculation and analysis,TM411
- SVM Based on SIFT and scene classification,TP391.41
- Based on Particle Swarm main power transformer insulation design,TM41
- Comparison of Alternative ACD Models Via Density and Interval Forecasts,F830.9
- Field Application of On-line Detection and Location Technology in UHF GIS Partial Discharge,TM835
- The Research on Intelligent Methods of Power Transformer Fault Diagnosis,TM41
- SCB11-1600/10 resin insulation dry-type power transformer R \u0026 D,TM412
- Research and Implemente of Partial Discharge Location System,TM41
- Study on Degradation Assessment of Oil-Paper Insulation and Feature Extracting of Partial Discharge of Transformer Based on Chaos Theory,TM401.2
- Research of De-noise and Pattern-recognition in Partial Discharge Detection System,TP391.41
- Research on RF and Analog Front End of Low Power Passive UHF RFID Tag Chip,TP391.44
- Fiber Optic AE Sensing System Research and Application,TN253
- The Failure Recognition Research of GIS Partial Discharge Signal Measured by the Pulse Current Method,TM595
- The Application of GIS Substation in Online Monitoring,TM76
- Test and Research on DC Partial Discharge Signal of Electrical Equipment,TM930
CLC: > Industrial Technology > Electrotechnical > Transformers, converters and reactors > Power transformers
© 2012 www.DissertationTopic.Net Mobile
|