Dissertation > Excellent graduate degree dissertation topics show

Research on the Principle of Adaptive Reclosure for Double-circuit Transmission Lines

Author: QiLiang
Tutor: LiYongLi
School: Tianjin University
Course: Proceedings of the
Keywords: double-circuittransmissionlines adaptiveauto-reclosure optimal trip scheme six sequence component declining periodic component uniform transmission line
CLC: TM762.2
Type: Master's thesis
Year: 2008
Downloads: 107
Quote: 3
Read: Download Dissertation

Abstract


Because of the economic efficiency, double-circuit transmission lines on thesame tower are being more widely used in China’s EHV transmission system. As theauto-recloser installed on the double-circuit lines operates in the conventional scheme,the possibility that the tripped phases may be reclosed to permanent faults does exists,which may cause the double-circuit lines both be tripped when reclosed topermanent cross-line faults, which is a quite severe threat to the stability of powersystem.To avoid the disadvantages mentioned above, a new technique called“adaptiveauto-reclosure”is proposed byChinese scholars, which first makes a distinction of thefault characteristic, and then would reclose the tripped phase on condition that thefault is transient. It is no doubt that the contribution to improve the power systemreliability and stability will be significant if the adaptive technique could be applied tothe auto-reclsoers of double-circuit transmission lines.When double-circuit lines are parallel connected at both ends, it is possiblethat more than two healthy different phases may exist after a multi-phase fault. In thispaper, an optimal trip scheme for double-circuit lines is proposed, compared toconventional trip scheme, the proposed scheme has advantages on trying to maintainthe system transmission capability, restraining the unbalanced components injectedinto system. It is available to improve the system stability, and creates better operationconditions for auto-devices like auto-recloser. Dynamic simulation and BPAsimulation have proved the conclusions.The precondition that double-circuit lines can be reclosed is that: after the faulthas been tripped, there are at least two different healthy phases still running.Consequently, there is probably going to be a multi-phase reclosure after amulti-phase fault. In this paper, it is proved that the electrical quantity at the faultpoint reflects the fault characteristic more clearly, and is less affected by the loadcondition. Based on this conclusion, an adaptive auto-reclosure criterion and reclosingstrategy for double-circuit lines are proposed, which can adaptively distinguish thefault characteristic under most fault types, and declining periodic component has lessaffect on the validity. For transmission lines of long distance or large distributed capacitance, usinglump parameter models for calculation can result in great error. Thus a more precisemethod for the calculation of voltages at fault point and power frequency voltages oftransient faulted phases is proposed based on the uniform transmission line model,which is not affected by the distribution parameter effects and helps to improve thereliabilityand sensitivityof the criterion.

Related Dissertations

  1. The Analysis and Computation of Coupling on the Non-uniform Multiconductor Transmission Lines,TN811
  2. Reconstruction of the Characteristics of Nonuniform Transmission Lines and Analysis of the Noise Effects,TN811.4
  3. Sensitivity Analysis of Networks Including Uniform and Nonuniform Transmission Lines,TN402
  4. Average Transformation Theory--Based Capacitive Level Sensor with Anti-Attachment,TP212
  5. Research on the Field and Circuit Characteristics of Non-uniform Transmission Line,TN811
  6. The Design and Research on the Parameters Calculation and Software of the Multi-tower High Voltage Transmission Line,TM726.1
  7. Research on Protective Relay Scheme for 220kV Double Circuit Lines on the Same Tower,TM77
  8. Research on Fault Phase Selector of Protective Relay for Double Circuit Line of the Same Tower Based on Six-Sequence Component Theory,TM753
  9. Study on Fault Location of Parallel Transmission Teed Line,TM764
  10. Directional Comparison Pliot Protection for Six-phase Transmission Lines,TM773
  11. Research of Protection Schemes and Their Application in the Quadruple Circuit Transmission Line,TM773
  12. Dual power switch switching Key Issues,TM762.1
  13. Studies on the Control of 10kV BZT Device Based on Automatic Adaptive Operation Mode,TM762
  14. Study on Fault Location of High Voltage Transmission Line Based on Hilbert-huang Transform,TM762.25
  15. Protection of Distribution System with Distributed Generations,TM762
  16. Interventional Excitation Controller Research and Design,TM762
  17. Engineering Research and Application of 220kV BZT Device,TM762
  18. Research on Integration Backup Automatic Power for Medium and Low Pressure,TM762
  19. Studies on Adaptive Single-phase Auto-reclosure Based on Wavelet Energy Spectrum Algorithm for EHV Transmission Lines,TM762
  20. Research on Automatic Black Start Scheme Formation System,TM762
  21. The Design and Implementation of Distributed transmission line fault locator,TM762.25

CLC: > Industrial Technology > Electrotechnical > Transmission and distribution engineering, power network and power system > Power system automation > Automatic control of electrical equipment > Automatic reclosing