A Feasibility Study of IMRT Dosimetric Verification Using Radiochromic Film
Author: ChenWeiJun
Tutor: WangShi;DiXiaoYun
School: Tsinghua University
Course: Biomedical Engineering
Keywords: radiochromic film intensity modulated radiotherapy dosimetric verification
CLC: R815
Type: Master's thesis
Year: 2010
Downloads: 5
Quote: 0
Read: Download Dissertation
Abstract
|
The purpose of this study is to investigate the dose response characteristic of EBT2 film which is scanned with different light sources. Then the IMRT dosimetric verification system which was composed by EBT2 film, Uniscan C880 scanner and FilmQA dosimetry analysis software was applied in clinical.The EBT2 film was placed in solid water phantom, radiated with 6MV photon beam whose delivered dose are span from 0 to 280 cGy. Then the film was scanned with flatbed color scanner, and the scanned images were separated into red, green and blue images. The characteristic of image’s dose response was analyzed respectively. The scanner’s scanning uncertainty and film orientation effect were tested to evaluate the IMRT dosimetric verification system which was composed by EBT2 film, Uniscan C880 flatbed scanner and FilmQA dosimetry software. Then the system was applied in a NPC case in experimental trial as well. 10 cases were tested by this system and mapcheck, the results were analyzed with DTA and Gamma index. The advancement of EBT2 film in IMRT dosimetric verification was investigated by setting various parameters to DTA and Gamma index.The results showed that sequence of dose response sensitivity of the EBT2 film is red, green and blue when scanned in different lights. Cubic polynomial fitting method can satisfy the requirement of dose response curve. The Uniscan C880 scanner’s single and multiple scanning uncertainties were 0.22% and 1.12% respectively. Film orientation had a big effect on scanner’s readout. The IMRT dosimetric verification system composed by EBT2 film, Uniscan C880 flatbed scanner and FilmQA dosimetry software was easy to use, and the results got from this system were accurate. Compared with mapcheck, EBT2 have a higher spatial resolution; can check out more spatial point’s dose difference.The IMRT dosimetric verification system based on radiochromic film EBT2 is easy to use and can acquire an accurate result. Due to the advantages of high spatial resolution, it is suitable to use in IMRT dose verification and is valuable for clinical application.
|
Related Dissertations
- Comparison of Six Intensity Modulated Radiation Therapyplans for Radical Treatment of Vertebral Column Mestastatic Carcinoma,R738.1
- Are whole and electronic portal imaging system in tune IMRT,R730.5
- Study on Radiochromic Films,TL818
- Study on Key Techniques of Multi Leaf Collimator Radiotherapy System,TH789
- Gross Tumor Volume and Clinical Target Volume Delineation and a Comparision of 3DCRT/IMRT Treatment Plans for Esophageal Carcinoma,R735.1
- Irradiation time expression in the mouse lung matrix metalloproteinase -9 and E-cadherin prime,R734.2
- Concurrent Chemoradiotherapy for Locally Advanced Non-small Cell Lung Cancer Clinical Outcomes of Patients with Malignant Lung Lesions Treated with Stereotactic Body Radiation Therapy,R734.2
- Features of Local Invasionness for Early Stage Nasal NK/T-Cell Lymphoma: Prognostic Significance and Delineation of Clinial Target Volume,R739.62
- The Change of Tumor Target Volume during Waiting Times for Intensity-modulated Radiotherapy (IMRT) in Nasopharyngeal Carcinoma (NPC),R739.63
- Study of Intensity Modulated Radiation Therapy of Cervical Cancer,R737.33
- The Study of the Optimize Radiotherapy Technology for Breast Cancer,R737.9
- Intrnsity-Modulated Radiotherapy Combined with Cetuximab for Locally Recurrent Nasopharyngeal Carcinoma and Reviewed Literatures,R739.63
- To Compare the Differents Imageological in Nasopharyngeal Carcinoma of IMRT and to Observe the Short-term Clinical,R739.63
- Comparison of Three Radiotherapy Techniques in Nasopharyngeal Carcinoma,R739.63
- Study on Dosage of Conventional and Intensity Modulated Radiotherapy for Early Stage Nasopharyngeal Carcinoma,R739.63
- Based on PET / CT in IMRT Mathematical Models and Algorithms,R814.42
- To Comparison in the Organs at Risk (OAR) the Influence of Conventional and Three Dimensional Conformal and Intensity-modulated Radiotherapy for Midpiece Esophageal Cancer,R735.1
- Preliminary Application of Kilo-volt Cone-beam Computed Tomography to Off-line Correction of Set-up Errors in Intensity-modulated Radiotherapy of Nasopharyngeal Carcinoma,R739.63
- Preliminary study of intensity modulated radiation therapy the Central Plains tumor volume and prognosis,R739.63
- 临床研究 Neo-adjuvant Docetaxel and Cisplatin Followed by Concurrent Docetaxel and Cisplatin with Intensity-modulated Radiation Therapy in Treatment of Locally Advanced Recurrent Nasopharynx Cancer,R739.63
CLC: > Medicine, health > Of Medical > Radiation Medicine > Radiotherapy
© 2012 www.DissertationTopic.Net Mobile
|