Abstract
|
With the continued development of seismic technology and theory , a new class of captive tuning force building structure system being in-depth study . The object of this study - mega - sub controlled structural system is one of the important one . To resolve the mega - sub controlled structural system giant collision between the sub- structure and sub- structure acceleration response issues such as excessive energy consumption damper can be installed in huge sub- structure of the top-level . The combination of mega - sub controlled structural system unique layout features , this article first suggested , design a savings longitudinal length can be adjusted to the size of the damping force to effectively solve the the mucus blocking problems caused by oxidation fluid damper , called adjustable fluid damper. And theoretical analysis of the damper , an expression of the relationship between the damping force and speed and intrinsic parameters , and the damping force speed curve with the number of orifice relationship is discussed in detail . The following conclusions: the fewer the number of orifice damping force - velocity curve slope , the smaller the contrary . Proved the effectiveness of the adjustable fluid damper adjustable . Finally, fluctuating wind and earthquake force mega - sub controlled structural system in response to the situation before and after the installation adjustable fluid damper comparative analysis , law research damper on the impact of the new structure of the system . The conclusion is: external dynamic action , fluid damper to the mega - sub controlled structural system damping value is not the bigger the better , but there is the optimization value ; reasonable selection of additional damping values ??will not change the giant - child - owned controlled structural system tuning force characteristics : additional damping giant - sub controlled structural system dynamic response further reduced, especially in the sub- structure acceleration response control most obvious . Mega - sub controlled structural system , excellent self- damping function and damper given the important role of the structure .
|
Related Dissertations
- The giant - sub controlled structural system of wind-induced vibration response of semi- active control of,TU352.1
- The giant - sub controlled structural system pulsation wind vibration response analysis,TU352.1
- Giant - sub controlled structure under seismic excitation control performance analysis,TU973.1
- Giant - sub controlled structural system in Vertical Seismic Response Analysis,TU352.1
- Damper system with a high level of seismic performance of steel,TU352.1
- Magnetorheological fluid damper mechanical properties of Research and Application,TB535.1
- Characteristic of Fluid Damper and Its Effect on the Whole-Spacecraft Vibration Isolation,TB535.1
- Research on Vibrtion Characteristic of Seat Suspension System Based on Air Spring and Mr Damper,U463.33
- Studies on Wind-induced Dynamic Response and Vibration Control of Guyed Cat-head Transmission Tower-line System,TM753
- Study on Some Key Technology of Vehicle Suspension System,U463.33
- Study of the Control of Semi-active Variable Damping System in Impact Load,TB535.1
- Structural Hydraulic Passive Energy Dissipation and Direct Driving Active Control Systems,TU311.3
- Study on Current Source with Sensitivity to Operational Condition of Magneto-Rheological Fluid Dampers,U463.33
- Control of Vehicle Semi-active Suspension Based on MR Damper,U463.33
- Dynamic Instability Analysis of Transmission Tower-Line System Subjected to Wind Load,TU347
- Shock absorber design and control strategy based ER materials,U463.33
- Rain-wind-induced Dynamic Response Analysis of Transmission Tower-Line System,TU311.3
- Magnetorheological fluid damping of the vehicle seat,U463.836
- Research on Controlled Damper for Multi-DIM Vibration Absorber,TB535.1
- Composite MTMD control wind-induced vibration of high-rise structure research,TU312.1
CLC: > Industrial Technology > Building Science > Building structure > Special Structure > Anti - shock structure,disaster prevention structures > Shock, isolation, and explosion-proof structure > Seismic structure
© 2012 www.DissertationTopic.Net Mobile
|