Dissertation > Excellent graduate degree dissertation topics show

The Imaging Anatomic Study of the L5 Pedicle and Its Value in PVP Procedure

Author: LiZiXiang
Tutor: LiuFengChun
School: Qingdao University
Course: Human Anatomy and Embryology
Keywords: L5 Vertebrae pedicle Three dimensional measurement Spiral CT PVP
CLC: R687.3
Type: Master's thesis
Year: 2005
Downloads: 61
Quote: 0
Read: Download Dissertation

Abstract


Objective To observe the angle of pedicle axis line of L5 vertebra with vertebral sagittal plane and horizontal plane, the space projective location at vertebral body of pedicle axis line and its angle of rectification. To probe into its role in helping PVP procedure. Material and Methods Thirty dry bone specimens of adult’s L5 vertebra were used. The continuous volumetric data with spiral CT scan were got in all specimens. The widest layer was selected as pedicle’s reconstructing plane during continuous images and the source images were reconstructed with multiplane reformation(MPR) in GE AW4.1 workstation. The following parameters were measured. (1)Angle between pedicle axis line and vertebral sigittal plane(E angle) (2)Angle between pedicle axis line and parallel line of upper endplate(F angle) (3)Angle of rectification of pedicle axis line(G angle) (4)space projective location at vertebral body of distal end of pedicle axis line. Statistic differences were analyzed. Results Through three-dimension measurement of thirty L5 vertebrae with spiral CT scan, the data of pedicle axis line are as follows: the sigittal angle of pedicle axis line (E angle) is 34.7±2.5°(left) and 34.9±3.0°(right) respectively, horizontal angle (F angle) 3.4±0.7°(left) and 3.0±0.8°(right), angle of rectification (G angle) 24.4±2.2°(left) and 24.0±2.5°(right). Statistic analysis shows that differences in dimensions between left and right pedicle were not found to be statistically significant. Space location at vertebral body of distal end of pedicle axis line all lie in the anterior upper part of the vertebral body. The tube of vertebral basilar vein all lie in the posterior center of the vertebral body. Conclusions Through dimensions study for L5 pedicle axis line with spiral CT scan and three-dimension reconstruction, reference values of E,F,G angle of pedicle axis line were established, and space projective location at vertebral body of distal end of pedicle axis line and tube of vertebral basilar vein were found. This information may prove to be of instructive significance in transpedicular PVP procedure.

Related Dissertations

  1. Chinese Young Men Waist-dimensional CT 4,5 Vertebral Pedicle Morphology and Clinical Significance of the Difference,R687.3
  2. Compared the Efficacy of Apofix and Pedicle Screws in the Treatment of Traumatic Atlantoaxial Instability,R687.3
  3. Investigate the Value of CT Reconstruction of Multi-mode After T-tube Cholangiography or ERCP in the Biliary Tract Disease,R657.4
  4. Applied Anatomic Study of the Parameters of Screw Fixation for the Sacroiliac Joint,R687.3
  5. Unstable and Burst Fracture of Thoracolumbar Vertebrae Treated by Pedicle Screw Instrumentation Plus Vertebral Body Bone Grafting,R687.3
  6. Posterior decompression and interbody fusion and pedicle screw fixation of multi-segmental lumbar spinal stenosis,R687.3
  7. A Comparison Analysis between PVP and PKP in Osteoporotic Vertebral Compressive Fractures,R687.3
  8. PVP and PKP Treatment of Osteoporotic Thoracolumbar Vertebral Compression Fracture Analysis of the Efficacy,R687.3
  9. Unilateral Using Pedicle Screws Treatment Very Lateral Type Prolapse of Lumbar Intervertebral Disc,R687.3
  10. The Study of Thoracic Pedicle Morphometry and Its Related Factors,R687.3
  11. Study on the Three-dimensional Measurement of Bubble Characteristic Parameters in Gas-Liquid Two Phase Flow,O359.1
  12. Research the Correlation of Heart Rate with Hepatic Scan Dely Time Using Msct,R816.5
  13. The Study of Clinical Application and Imaging Technology of 64-slice Spiral CT Angiography on Coronary Artery,R816.2
  14. Study on Accuracy of Pedicle Guide Wire Placement in the Lumbar Spine by MISS Robot with Manipulator Axial Position Guiding,R687.3
  15. The Study of the Antimicrobial Activity of the Ventriculoperitoneal Shunt System Treated by PVP-I,R651.1
  16. Experimental and Clinical Study of Preoperative Volume Evaluation in Living Donor Liver Transplantation with 64-Slice Spiral CT,R657.3
  17. Clinical Application of Preoperative Spiral CT Measurement to Guide Insertion of Cervical Pedicle Screw Fixation,R687.3
  18. Research of Multi-slice Spiral CT Angiography in Diagnosis of Pulmonary Embolism,R816.4
  19. In-stent Restenosis of Coronary Artery Imaging Assessment and Mechanism of Genetic Interference Inhibition,R541.4
  20. The Clinical Value of 64-slice Spiral CT Three Enhanced Inspection to the Preoperative Assessment of Gastric Cancer,R735.2
  21. Measurement of Lung Volumes from MSCT Images in Patients with Chronic Obstructive Pulmonary Disease,R563.9

CLC: > Medicine, health > Surgery > Orthopaedic Surgery ( movement system diseases,orthopedic surgery ) > Orthopedic surgery and surgery > Bone surgery
© 2012 www.DissertationTopic.Net  Mobile