Dissertation > Excellent graduate degree dissertation topics show

Experimental Study on Femoral Neck-shaft Projectional Angle Measured by X-ray Estimates Femoral Neck Anteversion and Its Clinical Application

Author: SuTao
Tutor: WangXiaoDong
School: Suzhou University
Course: Pediatrics
Keywords: developmental dislocation of the hip femoral neck anteversion angle neck-shaft angle neck-shaft projectional angle models clinical application
CLC: R816.8
Type: Master's thesis
Year: 2011
Downloads: 10
Quote: 0
Read: Download Dissertation

Abstract


Objective: To attempt to establish a skeletal model by femoral specimens with changes in femoral neck anteversion angle caused by the changes in neck-shaft projectional angle, the preliminary study on the quantitative relationship between changes in femoral neck anteversion and neck-shaft projectional angle, with statistical methods for analysis, sought to summary the relationship between them, and make preliminary validation using clinical case,may be applied to evaluate the developmental dislocation of the hip patients with the quantitative relationship.Methods: We utilized six children’s femoral specimens of different ages, made the specimens with femoral subtrochanteric osteotomy, and changed the femoral neck anteversion angle randomly from 0 ~ 90 degrees, then took the femur with standard anteroposterior X-ray, and measured neck-shaft projectional angle, with statistical methods for data analysis, summarized the dependent relationship between neck-shaft projectional angle and femoral neck anteversion angle. Verified the equation with a retrospective analysis of clinical cases and assessed its practical value.Results: We obtained the relationship between neck-shaft projectional angle Y and femoral neck anteversion angle X by analyzing the measured data with SAS9.13 statistical analysis software, coinciding exponential curve, the mathematical expression is: Y=e(4.908+0.0031X), it follows that the equation is X = (lnY-4.908) / 0.0031. And the neck-shaft projectional angle and anteversion angle correlation coefficient R=0.9835, the relationship between them is close. With the same degree’s change in FNA , through comparing two sets of data, the left and right side neck-shaft projectional angle, there was no significant difference (P>0.05).When the FNA is 0 degree, the neck-shaft projectional angle equals the true neck-shaft angle, regardless of the size of the ture neck-shaft angle, as long as the FNA increases to 90 degree, the neck-shaft projectional angle totally increased to 180 degree. When the true neck-shaft angle is constant, the neck-shaft projectional angle will increase gradually with the FNA.Conclusions: According to the established skeletal model, when the true neck-shaft angle is constant, the relationship between neck-shaft projectional angle and femoral neck anteversion angle meets exponential curve, and they are validated by the clinical cases, the clinical cases basically match the equation. It can provide guidance for clinical treatment and follow-up of children with developmental dislocation of the hip. Through measuring the neck-shaft projectional angle estimate the FNA, control the rotation osteotomy to correct femoral anteversion angle in clinical practice, direct femoral head and acetabulum concentric reduction. It can quantitatively measure the effect of postoperative follow-up of children with DDH.

Related Dissertations

  1. Research on Validation Methodology and Tool for Models of Simulation System,TP391.9
  2. Adaptive Control of Post-Boost Vehicle Using Multiple Models,TP273.2
  3. Design of Weapon Detection Device Control System,TP183
  4. Application of Semi-Structure in Leisure Dress,TS941.2
  5. Research on Construction Accident Factors’ Interaction Relations,TU714
  6. A Study on Effective Ways to Teach English Reading in Senior High Schools Based on the New Curriculum,G633.41
  7. The Morphological Structural Model and Visualization of Rapeseed (Brassica Napus L.) Plant,S565.4
  8. Experimental Study of Neural Stem Cells around the Lateral Ventricular Zone of the Hydrocephalus Rats,R742.7
  9. Applied Research Based on GARCH-VaR Model in Our ETF Risk Measurement,F224
  10. GREY-GARCH - based model of the Chinese stock market volume and price relationship,F224
  11. Research on the Models of GPS Height Fitting Based on BP Neural Network and Their Applications,P228.4
  12. Relationship Between Cell Volume and Cell Carbon, Nitrogen and Chlorophyll a Content for Marine Phytoplankton,Q948.8
  13. Research on the Process Optimization of the Jinan Second Wastewater Treatment Plant by Using Activated Sludge Mathematical Model,X703
  14. Investigation of Switehed Reluctance Generator Used in Wind Power System Based on DSP,TM352
  15. Small-Signal Stability Analysis of the Hybrid AC/DC Power System Containing FACTS Controllers,TM712
  16. The Clinical Observation on the Conservative Treatment of Developmental Dislocation of the Hip,R726.8
  17. Business model based on consumer behavior Chengdu fruit circulation analysis,F323.7
  18. RMB Exchange Rate and China-ASAN Trade,F752.7
  19. An Empirical Study of Credit Risk Evaluation for the Small and Medium-Sized Enterprises,F276.3
  20. Study on Construction Land Indicators Transaction Models between Towns and Countries in the Process of Urbanization,F301
  21. Urban spatial planning decision support system based on three-dimensional GIS implementation,TU984

CLC: > Medicine, health > Of Medical > Radiation Medicine > Each location and course of disease X - ray diagnosis and therapy > Surgery, orthopedics