Dissertation > Excellent graduate degree dissertation topics show

The Diagnosis Value of the Back-lead Electrocardiogram on Arrhythmia

Author: LiuBo
Tutor: HuiJie
School: Suzhou University
Course: Internal Medicine
Keywords: electrocardiogram arrhythmia back-lead diagnosis
CLC: R541.7
Type: Master's thesis
Year: 2011
Downloads: 10
Quote: 0
Read: Download Dissertation

Abstract


Objective: To investigate the recording methods of back-lead electrocardiogram and its diagnostic value for arrhythmia combined with conventional 12-lead electrocardiogram.Methods: This study enrolled 102 cases, including out-patients, in-patients and healthy volunteers. There were 58 cases of male and 44 cases of female with a mean age of (41.9±19.2)years old. They were subdivided into two groups: one group with sinus rhythm (n=82) and the other group with arrhythmia (n=20). The Conventional 12-lead electrocardiogram and six back-lead (B1-6) electrocardiograms were recorded in the sitting position, the right lateral position and the prone position respectively. The ratios of the amplitude of P wave and QRS waves (P/R ratio) in all leads were calculated, and the back lead and position with the maximum P/R ratio were defined as the best electrode placement and record position. Because all of the P waves in the group with arrhythmia were difficult to identify in the Conventional ECG, we analyzed the P waves in the best back lead and position to diagnose the arrhythmia compared with their esophageal ECG or intracardiac ECG.Results: (1) The best back-lead and position: In the Sitting position, there were 11 cases (10.8%) in B1, 14 cases(13.7%) in B2, 45 cases(44.1%) in B3, 20 cases(19.6%) in B4, 6 cases(5.9%) in B5 and 6 cases (5.9%) in B6 with the maximum P/R ratio respectively; in the right lateral position, there were 19 cases(8.8%) in B1,11 cases(10.8%)in B2,51 cases(50.0%)in B3,19 cases(18.6%)in B4,6 cases(5.9%)in B5 and 6 cases(5.9%) in B6 with the maximum P/R ratio respectively; in the prone position, there were 9 cases (8.8%) in both B1and B2, 58 cases (56.9%) in B3, 14 cases (13.7%) in B4, 6 patients (5.9%) in B5 and 6 patients (5.9%) in B6 with the maximum P/R ratio respectively. The P/R value in B3 lead in the three different positions was 0.1556±0.0788、0.1331±0.0700、0.1210±0.0784 respectively. The P/R value in B3 lead in the sitting position was maximum .There was statistically significance in the differences. (2) P wave in the group with sinus rhythm can be recognized clearly in both the back-lead and Conventional ECG. The P/R value of B3 was significantly larger than the lead II (0.1576±0.0814 vs. 0.1056±0.0644). There was statistically significance in the difference. (3) The diagnostic value of Back-lead ECG for arrhythmia was similar to the esophageal or intracardiac electrocardiogram.Conclusion: (1) The B3 lead in the sitting position was the best back-lead placement and recording position. (2)The back-lead electrocardiogram could be helpful for recognizing abnormal P wave more easily in some patients with arrhythmia, and elevating the diagnostic value for arrhythmia combining with conventional 12-lead ECG.

Related Dissertations

  1. Design and Development of Application Programme for Fault Analyzer Based on Wince Platform,TP311.52
  2. Research on the 6-Dof Fault Tolerant Control of the Vibration Isolation Platform with Eight Actuators,TB535.1
  3. A Simulation Study of the Effects of Ischemia to Spiral Waves in 2-D Human Ventricular Tissue,R318.0
  4. Research on Feature Extraction and Classification of Tongue Shape and Tooth-Marked Tongue in TCM Tongue Diagnosis,TP391.41
  5. Research on Classification Method of Tongue Substance Color and Tongue Coating Color Based on SVM,TP391.41
  6. Fault Diagnosis Method Based on Support Vector Machine,TP18
  7. Fault Diagnosis Research on Three-Tank System,TP277
  8. The Diagnosis of Modernity of Marx to Enlighten to Human’s Development,A811
  9. The Research and Implementation of Lgorithms on Microcalcification Detection,R816.4
  10. Study on Dynamic Electrocardiogram Monitoring System and Electrocardiosignal Processing Method,TH772.2
  11. The Dynamical Evaluation of Three Methods to Diagnose Mycoplasma Pneumoniae Infection in Children,R725.6
  12. Research and Application on Reliability Technology of Mine Hidrological Monitoring System,TD742.1
  13. The Study on Clinical Using of FISH and Cytology in Diagnosis and Surveillance of Recurrence in UC,R737.1
  14. Multislice spiral computed tomography analysis of aortic sinus arrhythmia anatomical characteristics and clinical relevance,R541.7
  15. Establishment and Application of a Reverse Transcription-loop-mediated Isothermal Amplification Method for Detection of Rubella Virus RNA,R440
  16. Fault Diagnosis Method Study of Hydraulic System of Concrete Pump,TU646
  17. The Related Analysis about QT Interval Variability,HRV and the Occurrence of Ventricular Arrhythmias in Acute Myocardial Infarction,R542.22
  18. Genetic Pedigree Investigation of Nonalcoholic Fatty Liver Disease,R575.5
  19. Design of the Adjustable Parameter ECG Signal Generator Based on DSP and MCU,TP368.12
  20. WEB-based remote monitoring system for electrical and mechanical equipment applied research,TP311.52
  21. Multi-channel Real-time Online Monitoring System for Polymerizers,TP274

CLC: > Medicine, health > Internal Medicine > Heart, blood vessels ( circulatory ) disease > Heart disease > Arrhythmia
© 2012 www.DissertationTopic.Net  Mobile