Dissertation > Excellent graduate degree dissertation topics show
A Three-Dimensional Finite Element Analysis for the Biomechanical Characteristics of Micro-Implant and the Bone Tissue
Author: LinDong
Tutor: LinShan
School: Fujian Medical
Course: Clinical Stomatology
Keywords: micro-implant an three dimensional finite element analysis Stress analysis Biomechanics
CLC: R783.6
Type: Master's thesis
Year: 2007
Downloads: 98
Quote: 0
Read: Download Dissertation
Abstract
|
Objective: The purpose of this study is to establish a three-dimensional finite element model for micro-implant-bone and to analyze the influence of different direction of force and different height of thread on the biomechanical characteristics of micro-implant-bone interface.Method: Using the commercial code of SOLIDWORKS and ANSYSworkbench software,the three-dimensional finite element models of micro-implant-bone complex were built up to analyze the influence of different direction of force and different height of thread on the biomechanical characteristics of micro-implant-bone interface.Result: A simulated orthodontic force which was 150 grams with five directions was applied to the head of micro-implant,that is, referring to the axis of micro-implant and starting from the head of micro-implant 0 degree、30 degree、45 degree、60 degree and 90 degree. On all the conditions, the Von-Mises and the displacement were focused on the cervix of the micro-implant. The Von-Mises and the displacement were very small. As the angle increased ,the maximum Von-Miser stress at the cervix of the implants were 0.612Mpa、3.118Mpa、4.103Mpa、4.809Mpa、5.159Mpa. the maximum displacement at the cervix of the implants were0.695μm、0.126μm、0.137μm、0.142μm、0.158μm .Using ANSYSworkbench the three-dimensional finite element modeling of the micro-implants-bone complexs were established by put the height of threaded implant as (0.1mm、0.15mm、0.2mm、0.25mm、0.3mm、0.35mm). On all the conditions , the Von-Mises and the displacement were focused on the cervix of the micro-implant.The Von-Mises and the displacement were very small. As the height of thread increased,the maximum Von-Miser stress at the cervix of the implants were 4.988Mpa、5.075Mpa、4.809Mpa、5.399Mpa、5.428Mpa、6.271Mpa, the maximum displacement at the cervix of the implants were 0.157μm、0.154μm、0.142μm、0.147μm、0.153μm、0.167μm .The height of the threaded implant as 0.2mm has the minimum stress and displacement.Conclusion: On all the conditions,the maximum Von-Miser stress and the maximum displacement were focused on the cervix of the micro-implant The Von-Mises stress and the displacement were mainly focused on the cortical bone.The maximum Von-Miser stress and the displacement were very small. The micro-implant can safely loaded with 150g force in different directions, especially the one in smaller angle. Different height of thread can have influence on the Von-Mises stress and the displacement on the cervix of the micro-implant .The height of threaded implant as 0.2mm has the minimum stress and displacement.
|
Related Dissertations
- The Establishment and Preliminary Application of the Three-dimensional Finite Element Model of Ankle Joint,R687.3
- The Combined Treatment of Complex Adult Angleclass Ⅱ Division 1,R783.5
- The Biomechanics and Imageology Preliminary Studies of Lumbar Intertransverse Absorbable Fusion Cage in the Process of Biodegradation,R687.3
- Three-dimensional Thermal Simulation and Structure Design of Phase Change Access Random Memory,TP333.8
- Shandong Province 64kg men's boxers before Zhiquan Biomechanical analysis technique,G886.1
- Walking Biomechanical analysis and risk of injury,G821
- Large opening pressure vessel structural finite element analysis and strength design,TH49
- Painting robot design and control method of writing,TP242.3
- Tube heat exchanger thermal and stress analysis,TQ051.5
- Application Research of the Evaluation of Occlusal Contacts in the Orthognathic Surgery Based on ABAQUS,R782
- Analysis and optimization of pipe roof rig drilling agency,U455.3
- Mechanical Analysis of the Deck Paving on the Cement Concrete Bridge with Different Waterproof and Cohesive Layers,U443.33
- Normal and degenerated nucleus pulposus cells viscoelasticity measurement,R681.53
- The Comparative Study of Two Deproteinized Methods on Xenogeneic Bone Graft Substitute Material,R687.3
- The Theoretical and Experimental Research of the Absorbable Patella Net,R687.3
- A Study on Design and Biomechanics of Enhanced Bioceramic Rod,R687.3
- Finite Element Analysis of the Effects of Traction on the Biomechanical Behavior of the Degenerated Cervical Spine,R681.55
- Finite Element Analysis of the Effects of Spondylolysis of L5 on the Biomechanical Behavior of the Lumbar Spine,R687.3
- Comparison of Effects and Biomechanical Study between DHS and LCP Fixation in Treatment of Intertrochanter Fracture of Femur,R687.3
- A New Way Based on Computational Fluid Dynamics Study the Asthma Mechanism by Using a Real Airway Model,R562.25
- Functionally graded plate with a hole stress analysis,O344.1
CLC: > Medicine, health > Oral Sciences > Oral orthotics > PROSTHETIC
© 2012 www.DissertationTopic.Net Mobile
|