Dissertation > Excellent graduate degree dissertation topics show
Simulation Research and Design for the Three-Phase Voltage Sag Simulator
Author: WangShuZuo
Tutor: YanXiangWu
School: North China Electric Power University
Course: Theory and New
Keywords: Voltage dips Voltage PWM Rectifier Voltage sag generator Matlab / Simulink simulation
CLC: TM714.2
Type: Master's thesis
Year: 2011
Downloads: 44
Quote: 0
Read: Download Dissertation
Abstract
|
As we all know, a lot of power quality problems caused by voltage dips , the three-phase voltage dips fault simulator is used to test device as a way of assessing the supply voltage dips and voltage short interruptions of electrical equipment . This paper systematically studied the realization of the three-phase voltage dips fault simulator designed by Back to the Back Voltage PWM converter topology main circuit structure of the three-phase voltage dips fault simulator ; the dq0 coordinate system voltage sag type , sag magnitude , duration formation methods , as well as the realization of accurate three-phase symmetrical and asymmetrical voltage dips ; using Matlab / Simulink simulation software reproduction of the seven types of typical voltage sag type a, B , C, D, E, F, G sag depth and duration of the simulation. Dips through analysis of the side of the fault simulation side converter (FSC) of the FFT spectrum of the maximum phase voltage , can be seen, low total harmonic content , the sine wave of the voltage waveform close to the standard ; the same time, the grid-side converter (GSC) side basic current and voltage in phase , the power factor of over 0.99 , the AC current total harmonic distortion (THD) is controlled in the range of 5% comprehensive , realistic simulation of the three-phase system may occur in a variety of voltage sag event , to verify the correctness and feasibility of the method and design circuit The simulation results also show that the three-phase voltage dips fault simulator can be used to assess not only the instant power supply voltage dips , short interruptions and voltage industrial passive load , can also be used to assess industrial active load , for example , solar and network devices .
|
Related Dissertations
- Research on the Control Scheme of Hybrid PWM Rectifier under Unbalanced Voltage,TM461
- Skid steer loader working device damping system design and research,TH243
- Simulation of Flexible HVDC Transmission System,TM721.1
- Tianjin Petrochemical grid dynamic security analysis and countermeasures,TM711
- Research and Application based on MATLAB / Simulink simulation model of high-pressure common-rail diesel engine,TK427
- Variable Load Electro-Hydraulic Servo Control Technology Research,TH137
- Study on Dual-PWM Variable-Frequency Speed Regulation System Used in Mine Hoister,TD633
- Modeling and Control of the Double Driver Wind Turbine,TM315
- Influence Assessment and Location Research of Voltage Sags Based Intelligent Algorithm,TM714.2
- Research on High-power Digital AC Servo System,TM921.541
- Research on Four Wheel Steering Control Method and Experimental System Design of Model Vehicle,U463.4
- Power Quality Monitoring System in Wind Farm Based on LabVIEW,TM614
- Reseach on Controlling Algorithm for Manipulator via Dynamic Model,TP242.2
- Power quality based on intelligent detection and recognition algorithms,TM711
- Research on Control Method of Energy Storage Based on Stand-alone Pv Generation,TM615
- Study on the Detection Method of Voltage Sag Based on DSP,TM714.2
- Research of Voltage Sag On-Line Inspection Device,TM714.2
- CNC linear drive motion control algorithm simulation analysis,TG659
- The Study of Control Strategies and System Modeling to DVR,TM761.12
- The Research on Pmsm Servo Control System Based on Dtc,TM341
CLC: > Industrial Technology > Electrotechnical > Transmission and distribution engineering, power network and power system > Theory and Analysis > Load analysis > Voltage regulation