Dissertation > Excellent graduate degree dissertation topics show
Electrochemiluminescence Detection on Microfluidic Chip
Author: ZhangGuoFan
Tutor: SunXueMei
School: Qingdao University of Science and Technology
Course: Organic Chemistry
Keywords: single-cell analysis microfluidic chip electrochemiluminescence detection chemically modified electrode carbon fiber micro-disk bundle electrode
CLC: O657.1
Type: Master's thesis
Year: 2011
Downloads: 110
Quote: 0
Read: Download Dissertation
Abstract
|
In the chapter one, the principle of microfluidic chip was introduced briefly. Then the detection methods of microfluidic chip including laser induced fluorescence, chemiluminescence, electrochemical detection and mass spectrometry were reviewed in detail. Finally, the four main methods of Langmuir-Blodgett method, self-assembly method, polymer mothod and sol-gel method for immobilizing Ru(bpy)32+ onto the electrode surface were summarized.In the chapter two, a kind of microfluidic chip electrochemiluminescent detection system(microfluidic chip-ECL) using glass chip was made. Ru(bpy)32+ as luminous reagent, the self-assemble carbon fiber microdisk bundle electrode (CFMBE) as working electrode, the optimum conditions of separation and detection of tripropylamine(TPA) was studied on the system, the conditions were pH 7.6 3.00×10(-2 mol·L-1 for phosphate buffer solution, 1.3 kV for the separation voltage, 1.2 V(vs. Ag/AgCl) for the detection potential, 1.0×10(-3 mol·L-1 for the concentration of Ru(bpy)32+, 1.0 kV and 10 s for the injection voltage and the injection time. The response for a series of seven injections of 1.0×10(-3 mol·L-1TPA resulted in a relative standard deviation of 2.6% for the ECL intensity and 0.67% for the migration time, respectively.In the chapter three, a kind of electrochemiluminescence micro-electrode was developed, which was immobilized Ru(bpy)32+ in carbon nanotubes(CNT)/Nafion composite film onto the ITO electrode surface. Tripropylamine(TPA) was determined with the modified electrode. the concentration limit of detection is 2.6×10(-9 mol·L-1 (S/N=3) and the linear range is 1.00×10(-8-5.00×10(-6 mol·L-1 with a correlation coefficient of 0.9986. The response for seven continuous cycles scan of 1.00×10(-7 mol·L-1 TPA resulted in a relative standard deviation of 2.3% for the ECL intensity. The micro-electrode performed good ECL signal, good reproducibility and rapid response time. The area of carbon nanotubes(CNT)/Nafion composite film was small in concide with the size of microfluidic chip, but CNT/Nafion composite films were easily fall off from the ITO electrode surface in process of the experiment.So this kind of modified electrode could not be applied in microfluidic chip electrochemiluminescent detection.In the chapter four, a noval electrochemiluminescence micro-electrode of Ru(bpy)32+-ester immobilized onto the sulfhydryl-derivated indium tin oxide(ITO) electrode surface with AuNPs/Cys composite films was employed. The ECL emission from AuNPs/Cys/ Ru(bpy)32+-ester composite film of TPA was investigated with TPA as a coreactant. The concentration limit of TPA is 3.5×10-9 mol·L-1(S/N=3) and the linear range is 1.00×10-8-1.00×10-5 mol·L-1 with a correlation coefficient of 0.9934. The response for seven continuous cycles scan of 1.00×10(-80 mol·L-1 TPA resulted in a relative standard deviation of 1.9% for the ECL intensity, AuNPs/Cys composite films were not fall off from the ITO electrode surface in process of the experiment, so the modified electrode had good stability. The area of AuNPs/Cys composite films on ITO electrode was coincide with the size of microfluidic chip, so the AuNPs/Cys/ Ru(bpy)32+-ester modified ITO electrode could be applied on microfluidic chip electrochemiluminescent detection.In the chapter five, the self-assemble microfluidic chip electrochemiluminescence detection system (microfluidic chip-ECL) was employed for the analysis of glutathione(GSH) in single leukemic cell with a carbon fiber microdisk bundle electrode(CFMBE). The optimum conditions of separation and detection were 5.00×10-3 mol·L-1 for the concentration of tris(2,2′-bipyridine) ruthenium(II)(Ru(bpy)32+), 2.00×10-2 mol·L-1 phosphate buffer(pH 7.4) for the buffer solution, 1.3 kV for the separation voltage, 1.0 kV and 15 s for the injection voltage and the injection time, and 1.4 V (vs. Ag/AgCl) for the detection potential. The limit of detection is 1.7×10-7 mol·L-1 (S/N=3) and the linear range is 5.00×10-7-1.00×10(-5 mol·L-1 with a correlation coefficient of 0.9976. The response for a series of seven injections of 5.00×10(-7 mol·L-1 GSH resulted in a relative standard deviation of 0.85% for the migration time, and 2.8% for the ECL intensity, respectively. A single leukemic cell in the running buffer was introduced to the double-T crossing by the electrokinetic flow, and then the cell was lysed rapidly under the high electric field of 1.0 kV. GSH in the single leukemic cell was electrically migrated to the detection end of separation channel and was detected on the CFMBE. The amount of GSH in the single leukemic cell was detected to be 0.158-1.32 fmol.
|
Related Dissertations
- Preparation, Characterization and Application of Prussian Blue Composite Nanomaterials,TB383.1
- Fabrication and Application of Novel Chemically Modified Electrodes,O657.1
- Studies on Microfluidic Chip Analysis Systems with Gas Diffusion Separation and Reflected Photometric Detection,O657.3
- Direct PCR from Plasma on Chip and Establishment of a Microfluidic Chemiluminescence SNP Analytical System,R440
- The Fabrication and Research of the Chemically Modified Electrode in the Detection of Water and Saccharide Content,X832
- Research on the Detection Methods and Technology of Microfluidic Chip Based on Image Processing,TP391.41
- The Key Techniques Research of Polymer Microfluidic Chips Mould for Hot Embossing Molding,TG66
- Functional Materials Modified Electrode and Its Application,TB34
- The Preparation of Nanomaterials Chemical Modified Electrode and Their Application in the Environmental Analysis,X830.2
- Construction of Functional Membrane Electrodes Based on Nano-Interface and the Applications,O657.1
- Studies on the Determination of Bisphenol A as Well as on the Simultaneous Determination of AA, UA and XA Using Nano-mesoporous Silica Modified Carbon Paste Electrode,O657.1
- A Microfluidic Chip-based Spatial Temperature Gradient Capillary Electrophoresis System for DNA Mutation Detection,Q523-3
- Study on the Assay of Pharmaceutical Ingredients with CE-ECL Technology Sensitized by a Modified Electrode,R917
- Preparation and Electrochemical Study of Carbon Nanotube Electrodes Modified with Layered Double Hydroxides-Intercalation Compounds,TB383.1
- The Preparation and Electrocatalytic Application of Metal Hexaycnaoefrrate Modified Electrodes,O646.5
- The Application Research of Lanthanon Doped Prussian Blue Analogue Chemically Modified Electrode for CE-ECL Analysis Technology,O657.1
- Study on Novel Chemically Modified Electrode and Its Applications for Environmental Monitoring and Food Safety,O657.1
- Research and analysis of application of the graphite electrode surface fixed ferricyanide,O646.54
- Chemically modified electrodes based on nano- materials research and application,O657.1
- The Preparation of Five Heme Protein Modified Electrode and Direct Elecctrochemistry,Q51
- Fabrication of Acetylene Black Composite Modified Electrode and Their Applications in the Determination of Environmental Hormone,X830
CLC: > Mathematical sciences and chemical > Chemistry > Analytical Chemistry > Instrument analysis ( physics and physical chemistry ) > Electrochemical analysis
© 2012 www.DissertationTopic.Net Mobile
|