At present, China’s metal mines underground are largely extension and application in multi-stage ventilator station system. In order to ensure the safty of underground mine production, give full play to the multi-stage ventilator station system’s optimal performance and achieve air flow distribution according to the production conditions, it is particularly important to monitor air flow, air pressure and other airstream parameters of station’s fan in real time accurately. However, there are clearly insufficient in monitoring the accuracy, control, versatility, anti-interference and so of the existing fan monitoring device.Based on this, the paper design a new monitoring device of air flow and air pressure for mine fan which based on ATmegal6single-chip microcomputer. It’s not only to achieve real-time accurate measurement of air flow and air pressure, but also for reversing fan can finish fan measurement. This device has a field correction function, which can be calibrated in different field conditions, the field measurement results more in line with the true value.According to the underground installation of station’s fan and ventilation characteristics, combined with the hydrodynamic Bernoulli’s equation, continuity equation and resistance law, etc, this paper establish a mathematical which model monitoring air flow and pressure. Then this paper discusses the monitoring device hardware and software design process, the hardware circuit to ATmegal6microcontroller as the core control chip, the high-precision differential pressure transmitter for the signal acquisition unit, with the secondary microcontroller, A/D converter, LED digital tube, the signal output circuit etc. achieve the data collection, processing, computing, local display and output. This device of the input and output signal take anti-interference isolation design. Finally, on-site testing, analysis of the data were processed. To meet the conditions underground complex measuring wind, the use of on-site calibration approaches to improve the testing precision of the air flowand air pressure of the fan.Monitoring device operation is stable, and the test results are accurate, preliminary design to achieve the desired effect, for the accurate monitoring mine ventilation provided strong support, has a broad prospect of application.

Related Dissertations

  1. Evaluation of Image Quality of Megavoltage Computed Tomography for Helical Tomotherapy Unit and Aplication for Dose Recalculation,R730.5
  2. The Effect of Frequencycontron on Flow Fields Environment in Bulk Curing Barn and Quality of Flue Cured Tobacco,S572
  3. System solver based on the three-dimensional conditions of the mine ventilation network,TD724
  4. Research on PSA/Cotton Blend Fabric of Coatinging of Water Resistance and Moisture Permeability,TS195.6
  5. Numerical Simulation and Experimental Study of Air-Assisted Sprayer of Orchard,S491
  6. Axial fan blade vibration non-contact measurement,TD441.2
  7. Study on Aerodynamic Noise Characteristics and Numerical Predicting Method of a Counter-Rotating Axial Fan,TH432
  8. Research and Application of the Attribute Reduction Algorithm Based on Improved Discernibility Matrix,TP18
  9. Optimization Design and Numerical Simulation of Axial-Flow Fans,TH432.1
  10. The Design of Optimal Design System of Micro Axial Flow Fans Based on 3-D Flow Field Analysis,TP306.2
  11. Study of the Characteristics of Unsteady Flow in A Cross-flow Fan with Porous Stabilizers,TH432
  12. Predict and Study on the Aerodynamic Noise of Semi-open Axial Fan of Air Conditioner Outdoor Unit,TH432.1
  13. Thermal Performance Calculation and Experimental Analysis of a Silicon Oil Fan Clutch,U463.211
  14. A Research on the Methods for Designing and Calculating Performances of Engine Cooling Fans,TK403
  15. A Research on the Methods for Calculating Performances and Stress of Engine Cooling Fans,U464.138
  16. Dual DSP -based power quality monitoring devices R \u0026 D,TM76
  17. Design of Testing Apparatus for Responses Speed of Flowmeter,TH814
  18. Development of Automobile Air Flow Meter Calibration System Based on the Theory of Wind Tunnel,TH814
  19. Numerical Simulation of the Flow Field for Air-conditioner Outdoor Set and the Noise Prediction of Its Axial Fan,TM925.12
  20. Research on the Monitoring Device for the Main Components of Combine Harvester,S225.3
  21. Study on the Energy Saving Control of the Cooling Water System of the Central Air Conditioning System,TU831.3

CLC: > Industrial Technology > Mining Engineering > Mine safety and labor protection > Mine ventilation > Ventilation measurement and instrumentation
© 2012 www.DissertationTopic.Net  Mobile